Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Physical & Chemical properties

Vapour pressure

Currently viewing:

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
vapour pressure
Type of information:
experimental study
Adequacy of study:
key study
Study period:
From 15 March, 2012 to 20 March, 2012
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study
Qualifier:
according to guideline
Guideline:
EU Method A.4 (Vapour Pressure)
Deviations:
no
Qualifier:
according to guideline
Guideline:
OECD Guideline 104 (Vapour Pressure Curve)
Deviations:
no
Qualifier:
according to guideline
Guideline:
EPA OPPTS 830.7950 (Vapor Pressure)
Deviations:
no
GLP compliance:
yes
Type of method:
effusion method: isothermal thermogravimetry
Key result
Temp.:
20 °C
Vapour pressure:
0.002 Pa
Remarks on result:
other: (i.e., equivalent to < 1.1 x 10-5 mm Hg)
Key result
Temp.:
25 °C
Vapour pressure:
0.006 Pa
Remarks on result:
other: (i.e., equivalent to < 4.3 x 10-5 mm Hg)
Conclusions:
Under the study conditions, the vapour pressure was determined to be <0.0015 Pa (i.e., equivalent to <1.1 x 10E-5 mm Hg) at 20°C and <0.0058 Pa (i.e., equivalent to <4.3 x 10E-5 mm Hg) at 25°C.
Executive summary:

A study was conducted to determine the vapour pressure of the test substance, Coco TMAC (98.4% active) by isothermal thermogravimetry (effusion method), according to OECD 104, EU Method A.4 and EPA OPPTS 830.7950 Guidelines, in compliance with GLP. Under the conditions of the study, the vapour pressure was determined to be <0.0015 Pa (i.e., equivalent to <1.1 x 10E-5 mm Hg) at 20°C and <0.0058 Pa (i.e., equivalent to <4.3 x 10E-5 mm Hg) at 25°C (Brekelmans, 2012).

Description of key information

Under the study conditions, the vapour pressure was determined to be <0.0015 Pa (i.e., equivalent to <1.1 x 10E-5 mm Hg) at 20°C and <0.0058 Pa (i.e., equivalent to <4.3 x 10E-5 mm Hg) at 25°C.

Key value for chemical safety assessment

Vapour pressure:
0.006 Pa
at the temperature of:
25 °C

Additional information

The vapour pressure was determined using the effusion method (isothermal thermogravimetry) according to OECD Guideline 104 and EU Method A.4 and/or  EPA OPPTS 830.7950 (Brekelmans, 2012).