Registration Dossier

Physical & Chemical properties

Particle size distribution (Granulometry)

Currently viewing:

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
particle size distribution (granulometry)
Type of information:
experimental study
Adequacy of study:
key study
Study period:
22.01.2014
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study
Qualifier:
according to guideline
Guideline:
OECD Guideline 110 (Particle Size Distribution / Fibre Length and Diameter Distributions - Method A: Particle Size Distribution (effective hydrodynamic radius)
GLP compliance:
no
Type of method:
Laser scattering/diffraction
Type of distribution:
volumetric distribution
Key result
Percentile:
D50
Mean:
57.6 µm
Remarks on result:
other: SD not indicated
Key result
Percentile:
D10
Mean:
11.4 µm
Remarks on result:
other: SD not indicated
Key result
Percentile:
D90
Mean:
144.7 µm
Remarks on result:
other: SD not indicated
Executive summary:

The median particle size L50 of the test substance is 57 µm.

Description of key information

The median particle size L50 of the test substance is 57 µm.

Additional information