Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Administrative data

Endpoint:
viscosity
Type of information:
experimental study
Adequacy of study:
key study
Study period:
11.12.2003
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study
Justification for type of information:
Purified K-HDO is a powder. Therefore no viscosity can be determined for the purified active substance. However because K-HDO is only manufactured as a 30 % aqueous formulation - Xyligen 30F - the viscosity has been determined for Xyligen 30F.

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
2004
Report date:
2004

Materials and methods

Test guideline
Qualifier:
according to guideline
Guideline:
OECD Test Guideline 114 (Viscosity of Liquids)
Deviations:
not specified
GLP compliance:
no
Type of method:
rotational viscometer (dynamic)
Standard covering the apparatus used:
Standard fluid, Newtonian test fluid Haake E 200 (serial-No: 12003/00032)

Test material

Constituent 1
Chemical structure
Reference substance name:
Cyclohexylhydroxydiazene 1-oxide, potassium salt
EC Number:
613-953-8
Cas Number:
66603-10-9
Molecular formula:
C6H11KN2O2
IUPAC Name:
Cyclohexylhydroxydiazene 1-oxide, potassium salt
Test material form:
liquid
Details on test material:
Xyligen 30F is a 30% aqueous solution of K-HDO.
Specific details on test material used for the study:
Xyligen 30F (= 30 % K-HDO in water) represents K-HDO as manufactured.

Results and discussion

Viscosityopen allclose all
Key result
Temp.:
20°C
Parameter:
dynamic viscosity (in mPa s)
Value:
4.6
Key result
Temp.:
40°C
Parameter:
dynamic viscosity (in mPa s)
Value:
3.4

Any other information on results incl. tables

Calibration of the viscosimeter:

Set point

115 ± 3 mPa s (with falling ball viscometer)

Result of the calibration

130 mPa s (VT 550 with NV-cup)

Xyligen 30 F

 

Dynamic viscosity (at 20 °C; 800 R/s; NV-testing cup)

 

1

5.2 mPas

2

4.0 mPas

mean at 20 °C:

4.6 mPas

Dynamic viscosity (at 40 °C; 800 R/s; NV-testing cup)

 

1

3.4 mPa s

2

3.5 mPa s

mean at 40 °C

3.4 mPa s

Applicant's summary and conclusion

Executive summary:

The dynamic viscosity of K-HDO as manufactured (Charge 02 - 0511) determined at 20 °C amounts to 4.6 mPa s and at 40 °C to 3.4 mPa s.