Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
flammable solids
Type of information:
experimental study
Adequacy of study:
key study
Study period:
15 December, 2016- 05 January, 2017
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study
Qualifier:
according to guideline
Guideline:
EU Method A.10 (Flammability (Solids))
Version / remarks:
2008 May 31
Deviations:
no
GLP compliance:
yes (incl. QA statement)
Specific details on test material used for the study:
Expiry date 28 July 2020
Storage room temperature
Key result
Test procedure:
burning rate test: preliminary screening test
Remarks on result:
other: In the preliminary test the test item could be ignited but the reaction zone did not propagate on the pile. Based on the results of the preliminary test, no main test was performed.
Remarks:
The test item is considered not highly flammable.
Interpretation of results:
GHS criteria not met
Remarks:
not highly flammable
Conclusions:
In the preliminary test the test item could be ignited but the reaction zone did not propagate on the pile. Based on the results of the preliminary test, no main test was performed.
The test item is considered not highly flammable.
Executive summary:

The purpose of the study was to evaluate the flammability of the test item.The test item was formed into a powder train. It was ignited by a gas flame and the burning rate was determined.

Two parallel flammability tests were performed. The tests were negative.The test item is not considered highly flammable under the conditions of this test.

Description of key information

The test item is considered not highly flammable.

Key value for chemical safety assessment

Flammability:
not classified

Additional information

In the preliminary test the test item could be ignited but the reaction zone did not propagate on the pile. Based on the results of the preliminary test, no main test was performed.

Justification for classification or non-classification