Registration Dossier

Diss Factsheets

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
explosive properties of explosives
Type of information:
experimental study
Adequacy of study:
key study
Study period:
2017-03-02
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study
Qualifier:
according to guideline
Guideline:
EU Method A.14 (Explosive properties)
GLP compliance:
yes
Specific details on test material used for the study:
Batch No. 7705878
Parameter:
thermal sensitivity - Koenen test: diameter of the orifice plate
Remarks on result:
not thermal sensitive if heated under defined confinement
Parameter:
sensitiveness to impact: impact energy (J)
Remarks on result:
not sensitive to impact using an impact energy of 40 J
Interpretation of results:
GHS criteria not met
Conclusions:
The test item has no explosive properties when tested according to EU Method A.14
Executive summary:

The test item has no explosive properties when tested according to EU Method A.14.

Description of key information

The test item has no explosive properties when tested according to EU Method A.14

Key value for chemical safety assessment

Explosiveness:
non explosive

Additional information

The test item has no explosive properties when tested according to EU Method A.14

Justification for classification or non-classification

The test item has no explosive properties when tested according to EU Method A.14. Classification is not required.