Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Administrative data

Endpoint:
flash point of flammable liquids
Type of information:
experimental study
Adequacy of study:
key study
Study period:
29 January 2018 - 02 Feb 2018
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
2018
Report date:
2018

Materials and methods

Test guidelineopen allclose all
Qualifier:
according to guideline
Guideline:
ISO 2719 (Determination of flash point - Pensky-Martens closed cup method)
Deviations:
no
Qualifier:
according to guideline
Guideline:
EU Method A.9 (Flash-Point)
Deviations:
no
Qualifier:
according to guideline
Guideline:
ASTM D93 (Standard test methods for flash point by pensky-martens closed cup tester)
Deviations:
no
Qualifier:
according to guideline
Guideline:
other: ASTM D 7094
Deviations:
no
Qualifier:
according to guideline
Guideline:
other: UN paragr. 32.4.1
Deviations:
no
GLP compliance:
yes (incl. QA statement)
Type of method:
closed cup
Flash point apparatus:
other: Eraflash flash-point tester
Remarks:
Eralytics, Vienna, Austria

Test material

Constituent 1
Reference substance name:
Non-volatile extract of Ginger, obtained from the roots of Zingiber officinalis (Zingiberaceae) by supercritical CO2 extraction
IUPAC Name:
Non-volatile extract of Ginger, obtained from the roots of Zingiber officinalis (Zingiberaceae) by supercritical CO2 extraction
Test material form:
liquid: viscous

Results and discussion

Flash point
Key result
Atm. press.:
1 013.25 hPa
Remarks on result:
no flash point according to standard method
Remarks:
No flash-point was observed below the temperature at which reaction and/or degradation of the test item occurred

Applicant's summary and conclusion

Conclusions:
Ginger - hot flavor CO2-to extract has no flash-point below the temperature at which reaction and/or degradation of the test item occurred.
Executive summary:

The test item Ginger - hot flavor CO2 -to extract has no flash-point below the temperature at which reaction and/or degradation of the test item occurred according to the regulations EC A.9, ASTM D93, ASTM D7094 and ISO 2719.