Registration Dossier
Registration Dossier
Data platform availability banner - registered substances factsheets
Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.
The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.
Diss Factsheets
Use of this information is subject to copyright laws and may require the permission of the owner of the information, as described in the ECHA Legal Notice.
EC number: 202-114-8 | CAS number: 91-99-6
- Life Cycle description
- Uses advised against
- Endpoint summary
- Appearance / physical state / colour
- Melting point / freezing point
- Boiling point
- Density
- Particle size distribution (Granulometry)
- Vapour pressure
- Partition coefficient
- Water solubility
- Solubility in organic solvents / fat solubility
- Surface tension
- Flash point
- Auto flammability
- Flammability
- Explosiveness
- Oxidising properties
- Oxidation reduction potential
- Stability in organic solvents and identity of relevant degradation products
- Storage stability and reactivity towards container material
- Stability: thermal, sunlight, metals
- pH
- Dissociation constant
- Viscosity
- Additional physico-chemical information
- Additional physico-chemical properties of nanomaterials
- Nanomaterial agglomeration / aggregation
- Nanomaterial crystalline phase
- Nanomaterial crystallite and grain size
- Nanomaterial aspect ratio / shape
- Nanomaterial specific surface area
- Nanomaterial Zeta potential
- Nanomaterial surface chemistry
- Nanomaterial dustiness
- Nanomaterial porosity
- Nanomaterial pour density
- Nanomaterial photocatalytic activity
- Nanomaterial radical formation potential
- Nanomaterial catalytic activity
- Endpoint summary
- Stability
- Biodegradation
- Bioaccumulation
- Transport and distribution
- Environmental data
- Additional information on environmental fate and behaviour
- Ecotoxicological Summary
- Aquatic toxicity
- Endpoint summary
- Short-term toxicity to fish
- Long-term toxicity to fish
- Short-term toxicity to aquatic invertebrates
- Long-term toxicity to aquatic invertebrates
- Toxicity to aquatic algae and cyanobacteria
- Toxicity to aquatic plants other than algae
- Toxicity to microorganisms
- Endocrine disrupter testing in aquatic vertebrates – in vivo
- Toxicity to other aquatic organisms
- Sediment toxicity
- Terrestrial toxicity
- Biological effects monitoring
- Biotransformation and kinetics
- Additional ecotoxological information
- Toxicological Summary
- Toxicokinetics, metabolism and distribution
- Acute Toxicity
- Irritation / corrosion
- Sensitisation
- Repeated dose toxicity
- Genetic toxicity
- Carcinogenicity
- Toxicity to reproduction
- Specific investigations
- Exposure related observations in humans
- Toxic effects on livestock and pets
- Additional toxicological data
Toxicity to microorganisms
Administrative data
Link to relevant study record(s)
- Endpoint:
- activated sludge respiration inhibition testing
- Type of information:
- experimental study
- Adequacy of study:
- key study
- Study period:
- 6 Sep 1999 - 10 Sep 1999
- Reliability:
- 1 (reliable without restriction)
- Rationale for reliability incl. deficiencies:
- comparable to guideline study
- Qualifier:
- equivalent or similar to guideline
- Guideline:
- OECD Guideline 209 (Activated Sludge, Respiration Inhibition Test
- Version / remarks:
- 1984
- Deviations:
- yes
- Remarks:
- Less inoculum was used than as specified in OECD 209 (1984). However, as the validity criteria were met, this does not influence the results of the study.
- Qualifier:
- according to guideline
- Guideline:
- other:
- Version / remarks:
- Procedure 'Amtsblatt der EG L 133 Teil C: Biologische Abbaubarkeit: Prüfung der Atmungshemmung' was used, which corresponds largely to OECD 209.
- Deviations:
- no
- Principles of method if other than guideline:
- Procedure 'Amtsblatt der EG L 133 Teil C: Biologische Abbaubarkeit: Prüfung der Atmungshemmung' was used, which corresponds largely to OECD 209.
- GLP compliance:
- yes
- Specific details on test material used for the study:
- Purity 98.1%
- Analytical monitoring:
- no
- Vehicle:
- no
- Details on test solutions:
- PREPARATION AND APPLICATION OF TEST SOLUTION
- Method: Direct application of test substance to test vessel
- Differential loading: 560, 1000, 1800, 3200, 5600 mg/L
- Controls: Control without test item, abiotic control (no inoculum, 10 000 mg/L test item)
- The weighed test item was stirred overnight in ~130 ml deionized water.
- Composition of synthetic medium: not specified - Test organisms (species):
- activated sludge, domestic
- Details on inoculum:
- - Name and location of sewage treatment plant where inoculum was collected:
activated sludge of a sewage treatment plant which is operated with municipal sewage (Wupperverband)
- Pretreatment: no pre-treatment
- Initial biomass concentration: 320 mg/L, which is lower than what OECD209 (1984) prescribes (i.e. 1.6 g/L). Due to the strong oxygen depletion of the used activated sludge, a lower biomass concentration was used. - Test type:
- static
- Water media type:
- freshwater
- Limit test:
- no
- Total exposure duration:
- 3 h
- Test temperature:
- 20 ± 2 °C
- pH:
- 7.2-7.9
- Dissolved oxygen:
- Test solution start: 5.9-9.4 mg/L
Test solution end: 2.8-9.4 mg/L - Nominal and measured concentrations:
- Nominal: 560, 1000, 1800, 3200, 5600 mg/L (abiotic control: 10 000 mg/L). Nominal concentrations are not analytically confirmed, thus effect concentrations are based on nominal concentrations.
- Details on test conditions:
- TEST SYSTEM
- Test vessel: not specified
- Aeration: constant aeration
- No. of vessels per concentration (replicates): 1
- No. of vessels per control (replicates): 2
- No. of vessels per abiotic control (replicates): 1
- Sludge concentration (weight of dry solids per volume): 320 mg/L
TEST MEDIUM / WATER PARAMETERS
- Source/preparation of dilution water: deionized water
OTHER TEST CONDITIONS
- Adjustment of pH: not specified
- Photoperiod: not specified
- Light intensity: not specified - Reference substance (positive control):
- yes
- Remarks:
- 3,5-Dichlorphenol
- Key result
- Duration:
- 3 h
- Dose descriptor:
- EC50
- Effect conc.:
- 2 170 mg/L
- Nominal / measured:
- nominal
- Conc. based on:
- test mat.
- Basis for effect:
- inhibition of total respiration
- Key result
- Duration:
- 3 h
- Dose descriptor:
- EC10
- Effect conc.:
- 817 mg/L
- Nominal / measured:
- nominal
- Conc. based on:
- test mat.
- Basis for effect:
- inhibition of total respiration
- Details on results:
- - Blank controls oxygen uptake rate:
26.6-29.1 mg/L/h, average 27.9 mg/L/h
- Coefficient of variation of oxygen uptake rate in control replicates: not specified in report, calculated based on individual respiration rates of controls: 6.3%. This meets the validity criterium, the respiration rates of the two controls are within 15% of each other. - Results with reference substance (positive control):
- - Results with reference substance valid? Not specified. Inhibition lowest test concentration (2.5 mg/L): 0.0%, highest concentration (40 mg/L): 85.7%.
- Relevant effect levels: EC50: 13 mg/L, which is within the accepted range of 5-30 mg/L. - Reported statistics and error estimates:
- Effect level determined using Probit analysis
- Validity criteria fulfilled:
- yes
- Remarks:
- Control respiration rates are within 15% of each other (i.e. 6.3%) and the EC50 of the reference substance is between 5-30 mg/L (i.e. 13 mg/L).
- Conclusions:
- Based on the measurements, an EC50 of 2170 mg/L was found for N,N-Bis-(hydroxyethyl)-m-toluidin in an activated sludge respiration inhibition test.
- Executive summary:
N,N-Bis-(hydroxyethyl)-m-toluidin was tested in an activated sludge respiration inhibition test. The EC50 value for respiration inhibition was determined to be 2170 mg/L, the EC10 was 817 mg/L.
A method which corresponds closely to OECD 209 (1984) was used. A clear dose-response curve was found for the test item. The activated sludge showed good performance in the reference test and thus was acceptable for use. The test was performed under GLP and subject to a Quality Assurance check. Based on these reasons, the reliability of the study is evaluated as Klimisch Score 1, comparable to guideline study.
Reference
Test item concentration (mg/L) |
Respiration rate test item (mg/L/h) |
Abiotic O2 depletion (mg/L/h) |
Respiration rate abiotic O2 depletion (mg/L/h) |
Inhibition (%) |
560 |
26.6 |
0.0* |
26.6 |
4.7 |
1000 |
24.0 |
0.0* |
24.0 |
14.0 |
1800 |
16.8 |
0.0* |
16.8 |
39.8 |
3200 |
8.3 |
0.0* |
8.3 |
70.3 |
5600 |
3.0 |
0.0* |
3.0 |
89.2 |
Control average |
27.9 |
|
||
Control vessel 1 |
29.1 |
|||
Control vessel 2 |
26.6 |
*: The abiotic O2 depletion was tested at test item concentration of 10000 mg/L. Because there was no abiotic O2 depletion found in this study, also lower concentrations of test item will not lead to O2 depletion (derived values).
Description of key information
N,N-Bis-(hydroxyethyl)-m-toluidin was tested in an activated sludge respiration inhibition test. The EC50 value for respiration inhibition was determined to be 2170 mg/L, EC10 was 817 mg/L.
Key value for chemical safety assessment
- EC50 for microorganisms:
- 2 170 mg/L
- EC10 or NOEC for microorganisms:
- 817 mg/L
Additional information
A method which corresponds closely to OECD 209 (1984) was used. A clear dose-response curve was found for the test item. The activated sludge showed good performance in the reference test and thus was acceptable for use. The test was performed under GLP and subject to a Quality Assurance check. Based on these reasons, the reliability of the study is evaluated as Klimisch Score 1, comparable to guideline study.
Information on Registered Substances comes from registration dossiers which have been assigned a registration number. The assignment of a registration number does however not guarantee that the information in the dossier is correct or that the dossier is compliant with Regulation (EC) No 1907/2006 (the REACH Regulation). This information has not been reviewed or verified by the Agency or any other authority. The content is subject to change without prior notice.
Reproduction or further distribution of this information may be subject to copyright protection. Use of the information without obtaining the permission from the owner(s) of the respective information might violate the rights of the owner.