Administrative data

Endpoint:
adsorption / desorption: screening
Type of information:
experimental study
Adequacy of study:
key study
Reliability:
2 (reliable with restrictions)
Rationale for reliability incl. deficiencies:
guideline study with acceptable restrictions

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
2018
Report date:
2018

Materials and methods

Test guideline
Qualifier:
according to guideline
Guideline:
OECD Guideline 121 (Estimation of the Adsorption Coefficient (Koc) on Soil and on Sewage Sludge using High Performance Liquid Chromatography (HPLC))
GLP compliance:
no
Type of method:
HPLC estimation method
Media:
soil

Test material

Constituent 1
Reference substance name:
Caramel (color)
EC Number:
232-435-9
EC Name:
Caramel (color)
Cas Number:
8028-89-5
Molecular formula:
C6H12OH
IUPAC Name:
Caramel
Radiolabelling:
not specified

Study design

Test temperature:
40°C +/- 1°C (oven temperature)

HPLC method

Details on study design: HPLC method:
-Reference substances: sodium nitrate, acetanilide, atrazine, linuron, fenthion, trifluralin, 4,4'-DDT
-Preparation of working solutions: see the tables below
-System: 1260 Infinity II LC : (Agilent)
-Columns: HYPERSIL CN-CPS 5μm (4.6 x 150 mm)
-Sample injection: 5 μL
-Oven temperature: column = 40°C +/- 1°C
-Mobil phase and program:
Isocratic mode
Flow : 1.25mL/min
A : 45% Ultrapure water (18.2 megaohms/cm)
B : 55% Methanol (HPLC-MS grade)
Detector: UV (190-800nm), Chromatogram analysis at 210 nm.

Results and discussion

Adsorption coefficient
Key result
Type:
log Koc
Value:
ca. 0.432 dimensionless

Results: HPLC method

Details on results (HPLC method):
More details in the table below.

Repeatability:
The values of log Koc derived from individual measurements are within a range of 0.25 log unit, so within the criteria of the OECD 121 guideline.

Any other information on results incl. tables

Test item Quantity introduced in the column (ng) Retention times Log k' Log Koc
Caramel Colour E150c 570 3,86 -0,0890 0,422*
Caramel Colour E150c 570 3,868 -0,0870 0,441*

0,432

*It is important to note that there is no reference substance with a retention time below the test item retention time. The Log Pow was measured with an extrapolation of the regression.

Applicant's summary and conclusion

Validity criteria fulfilled:
not specified
Conclusions:
The estimated Adsorption Coefficient (Koc) logarithm of the test item on Soil is <1.25 (about 0.432 using extrapolation of the regression).