Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Physical & Chemical properties

Flammability

Currently viewing:

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
flammable solids
Type of information:
experimental study
Adequacy of study:
key study
Study period:
03.05. - 04.05.2000
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study
Qualifier:
according to guideline
Guideline:
EU Method A.10 (Flammability (Solids))
Version / remarks:
1992
Deviations:
no
GLP compliance:
yes
Key result
Test procedure:
burning rate test: preliminary screening test
Remarks on result:
substance does not ignite and propagate combustion either by burning with flame or smouldering along 200 mm of the powder train within the 2 minutes test period
Interpretation of results:
GHS criteria not met
Conclusions:
Since the test item could not be ignited with a flame in the preliminary test, the test item is not considered to be a highly flammable solid.
Executive summary:

The purpose of this study was the determination of the flammability (solids) of the test item according to the EU method A.10. The test item melted and could not be ignited with a flame in the preliminary test. Therefore, the performance of the main test was not necessary. Thus, the test item is not considered to be a highly flammable solid.

Description of key information

Since the test item could not be ignited with a flame in the preliminary test, the test item is not considered to be a highly flammable solid.

Key value for chemical safety assessment

Flammability:
not classified

Additional information

Justification for classification or non-classification

The test item has not to be classified as flammable solid, flammable gas, flammable liquid, flammable in contact with water, pyrophoric solid, pyrophoric liquid or self-heating substance according to Regulation (EC) No 1272/2008.