Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Physical & Chemical properties

Flash point

Currently viewing:

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
flash point, other
Type of information:
experimental study
Adequacy of study:
key study
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study
Qualifier:
according to guideline
Guideline:
ISO 2719 (Determination of flash point - Pensky-Martens closed cup method)
Version / remarks:
2002
Type of method:
closed cup
Key result
Remarks on result:
no flash point according to standard method

Preliminary Test

No flammable vapour/air mixture was produced at temperatures up to 370°C. At this temperature the instrument stops automatically, since this is the maximum temperature. Inthevisual observationafter the test,thetestitem remained as a black liquid residue(original colour: brown)outside and inside the sample cup. The change of colour indicated reaction and/ordecomposition of the test item. In order to avoidfurther damage to theinstrument, it was decidednottorepeatthe initial test. From this, it was concluded that the test item has no flash point up to 370°C.

Conclusions:
no flash-point up to 370°C

Description of key information

Key value for chemical safety assessment

Additional information

no flash-point up to 370°C