Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Administrative data

Endpoint:
relative self-ignition temperature (solids)
Data waiving:
study scientifically not necessary / other information available
Justification for data waiving:
other:
Cross-reference
Reason / purpose for cross-reference:
data waiving: supporting information
Reference
Endpoint:
flash point, other
Type of information:
experimental study
Adequacy of study:
key study
Study period:
august 2017
Reliability:
2 (reliable with restrictions)
Rationale for reliability incl. deficiencies:
comparable to guideline study
Qualifier:
equivalent or similar to guideline
Guideline:
other: ASTM D92
GLP compliance:
no
Type of method:
open cup
Flash point apparatus:
other: Anton Paar Model CLA 5 Automatic Cleveland Flash & Fire Point Tester
Key result
Flash point:
236 °C
Atm. press.:
1 013 hPa
Interpretation of results:
GHS criteria not met
Conclusions:
Flash point is 236C > 200C
Executive summary:

Flash point is 236C > 200C using equivalent method to ASTM D92