Diss Factsheets

Administrative data

Endpoint:
flash point of flammable liquids
Data waiving:
study technically not feasible
Justification for data waiving:
the study does not need to be conducted because the flash point is only relevant to liquids and low melting point solids
Justification for type of information:
JUSTIFICATION FOR DATA WAIVING
In accordance with section 2 of REACh Annex XI, flash point measurement does not apply to solids, and melting point is above the highest CLP classification threshold. Please refer to Flammable solids under IUCLID section 4.13.
Cross-reference
Reason / purpose for cross-reference:
data waiving: supporting information
Reference
Endpoint:
flammable solids
Type of information:
experimental study
Adequacy of study:
key study
Study period:
From 2008-07-07 to 2008-10-07
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study
Remarks:
The study was conducted according to an internationally recognised method, and under GLP. No deviation affected the quality of the study. The substance is considered to be adequately characterised with its purity. Therefore full validation applies.
Qualifier:
according to guideline
Guideline:
EU Method A.10 (Flammability (Solids))
GLP compliance:
yes (incl. QA statement)
Remarks:
Inspected on 05th to 06th and 26th to 30th November 2007 / Decision 30 April 2008 / Signed on 12th November 2008
Key result
Test procedure:
burning rate test: preliminary screening test
Remarks on result:
substance does not ignite and propagate combustion either by burning with flame or smouldering along 200 mm of the powder train within the 2 minutes test period

During the preliminary test (contact time of about 2 minutes), the substance melted immediately in contact with the ignition source, and could not be ignited.

Therefore, no main test was performed.

Interpretation of results:
not classified based on GHS criteria
Remarks:
GHS and EU-CLP criteria not met
Conclusions:
The test item is NOT classified as a flammable solid according to Regulation (EC) N°1272/2008 (CLP) criteria.
Executive summary:

The substance was tested for its flammable properties, according to EC A10 guideline, and under GLP.

During the preliminary assay, the item could not be ignited within the 2-min duration of application of the burner flame. Therefore no main test was performed.

Data source

Materials and methods

Results and discussion

Applicant's summary and conclusion