Registration Dossier

Diss Factsheets

Administrative data

First-aid measures

Emergency measure - Inhalation: Remove promptly to fresh air. If not breathing, administer
artificial respiration. Administer oxygen if breathing is
difficult. Seek medical advice if adverse reaction occurs
and persists.
Emergency measure - Eyes: Flush immediately with copious amounts of water or saline,
including under eyelids.
Emergency measure - Skin: Wash affected area with soap and water.
Emergency measure - Ingestion: Do not induce vomiting. Seek medical advice if adverse
reaction occurs and persists.

Fire-fighting measures

Recommended extinguishing agent: Water spray, dry powder, carbon-dioxide, foam.

Product arising from burning: None known, but may produce toxic fumes including oxides of
carbon and nitrogen.

Product determined by test: N

Protective equipment: Full protection by suitable clothing and positive pressure,
self-contained breathing apparatus.

Accidental release measures

Emergency measures in case of spillage: Wear personal protection. Collect spillage. Avoid wet
waste discharge to drains/surface water.

Handling and storage

Handling: The substance should be used only in well ventilated work
areas, by process operators wearing protective clothing,
gloves and dust masks.

Storage: In a cool place, avoiding direct sunlight.

Packaging of the substance and or preparation: To be packaged in sealed containers.

Transport information

Shippingopen allclose all
SpecialProvisionsopen allclose all
Shippingopen allclose all
Remarksopen allclose all

Marine transport (UN RTDG/IMDG)

Shippingopen allclose all
Remarksopen allclose all

Air transport (UN RTDG/ICAO/IATA)

Shippingopen allclose all
Special provisions / remarks
Remarks:
Transport code: None known
Transport: Should be transported in sealed containers, secured against
the risk of falling or other damage.
SpecialProvisionsopen allclose all

Exposure controls / personal protection

Stability and reactivity

Danger other than fire: None known.

Chemical reaction with water: None known.

Dust explosion: None known.

Dust explosion determined by test: N

Disposal considerations

Industry - Possibility of recovery/recycling: Not applicable: there should be no unreacted substance
remaining at the end of the process.

Industry - Possibility of neutralisation: No methods known.

Industry - Possibility of destruction: controlled discharge: All process waste directed to incinerator. Only floor
washings will go to waste water treatment plant; this water
is normally discharged to municipal foul sewer. If
significant contamination of floor washings is suspected,
these too are directed to the incinerator.

Industry - Possibility of destruction - incineration: 661 - Incinerator with flue gas scrubbing.

Public at large - Possibility of recovery/recycling: N/A

Public at large - Possibility of neutralisation: N/A

Public at large - Possibility of destruction: controlled discharge: N/A

Public at large - Possibility of destruction - incineration: N/A

Public at large - Possibility of destruction - water purification: N/A

Public at large - Possibility of destruction - others: Substance will not be available to the public.