Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Administrative data

Endpoint:
flammable solids
Type of information:
experimental study
Adequacy of study:
key study
Study period:
Start of experiment: 01 December 2016 End of experiment: 01 December 2016, The final report issued 27 January 2017.
Reliability:
1 (reliable without restriction)

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
2017
Report date:
2017

Materials and methods

Test guideline
Qualifier:
according to guideline
Guideline:
EU Method A.10 (Flammability (Solids))
Deviations:
no
GLP compliance:
yes (incl. QA statement)

Test material

Constituent 1
Chemical structure
Reference substance name:
hexasodium 5,5'-{[2,7-disulfonato-9-(2-sulfonatophenyl)-9H-xanthene-9-ylium-3,6-diyl]bis(azanediyl)bis[(2,4,6-trimethyl-3,1-phenylene)aminosulfonyl]}diisophthalate
EC Number:
854-560-3
Cas Number:
1891094-25-9
Molecular formula:
C53H38N4Na6O22S5
IUPAC Name:
hexasodium 5,5'-{[2,7-disulfonato-9-(2-sulfonatophenyl)-9H-xanthene-9-ylium-3,6-diyl]bis(azanediyl)bis[(2,4,6-trimethyl-3,1-phenylene)aminosulfonyl]}diisophthalate
Test material form:
solid: particulate/powder

Results and discussion

Flammable solids
Key result
Test procedure:
burning rate test: preliminary screening test
Remarks on result:
substance does not ignite and propagate combustion either by burning with flame or smouldering along 200 mm of the powder train within the 2 minutes test period

Any other information on results incl. tables

The test item would be considered flammable if the main test take less than 45 seconds.

In all other cases the test item is not considered flammable.

In this study the test item could not ignited. Therefore, the substance is considered not to be highly flammable

Applicant's summary and conclusion

Interpretation of results:
not classified based on GHS criteria
Conclusions:
.The test item is not highly flammable in the conditions of this test.
Executive summary:

Introduction

The purpose of the study is to evaluate the flammability of the test item.The test item is formed into a powder train. It is ignited by a gas flame and the burning rate is determined.

Results

Two parallel flammability tests were performed. The tests were negative.

Conclusion

The test item is not highly flammable in the conditions of this test.