Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Administrative data

Endpoint:
vapour pressure
Type of information:
experimental study
Adequacy of study:
key study
Study period:
4 Aug - 12 Aug 2020
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
2020
Report date:
2020

Materials and methods

Test guideline
Qualifier:
according to guideline
Guideline:
OECD Guideline 104 (Vapour Pressure Curve)
Deviations:
no
GLP compliance:
yes (incl. QA statement)
Remarks:
Hessisches Ministerium für Umwelt, Klimaschutz, Landwirtschaft und Verbraucherschutz, Wiesbaden, Germany
Type of method:
effusion method: Knudsen cell

Test material

Constituent 1
Chemical structure
Reference substance name:
1-(2,2,4-trimethyl-1,2-dihydroquinolin-1-yl)ethan-1-one
EC Number:
665-911-3
Cas Number:
5855-23-2
Molecular formula:
C14 H17 N O
IUPAC Name:
1-(2,2,4-trimethyl-1,2-dihydroquinolin-1-yl)ethan-1-one

Results and discussion

Vapour pressureopen allclose all
Temp.:
20 °C
Vapour pressure:
0.001 hPa
Remarks on result:
other: interpolated from the experimental data (vapour pressure: effusion method)
Temp.:
25 °C
Vapour pressure:
0.001 hPa
Remarks on result:
other: interpolated from the experimental data (vapour pressure: effusion method)
Vapour pressure at 50°C (if relevant for classification of gas under pressure)
Vapour pressure:
0.017 hPa
Remarks on result:
other: interpolated from the experimental data (vapour pressure: effusion method)

Any other information on results incl. tables

Individual results
The vapour pressure was measured in the temperature range of 20 °C to 50 °C. The measured vapour pressures at the corresponding temperatures are listed in the Table below. After the measurement a mass loss of approx. 83 % (w/w) was determined.

Temperature / °C Vapour Pressure /hPa
20 8.1 x 10-4
25 1.3 x 10-3
30 2.2 x 10-3
35 3.8 x 10-3
40 6.4 x 10-3
45 1.1 x 10-2
50 1.7 x 10-2
40 6.0 x 10-3

From the measured data the parameters A, B and C of the Antoine equation can be derived by regression.

log(p/ hPa) = A + (B/ (C + T [°C]))

 

The evaluated Antoine parameters are listed in the Table below.

A 11.37458
B -4249.00
C 273.15

The vapour pressure values for 20, 25 and 50 °C (see Table below) were interpolated, using these Antoine constants A, B and C.

T /°C p /hPa p /Pa
20 7.6 x 10-4 7.6 x 10-2
25 1.3 x 10-3 1.3 x 10-1
50 1.7 x 10-2 1.7

 

Applicant's summary and conclusion