Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Physical & Chemical properties

Partition coefficient

Currently viewing:

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
partition coefficient
Type of information:
experimental study
Adequacy of study:
key study
Study period:
Experimental Phase: 14 June 2020 to 05 September 2020
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study
Qualifier:
according to guideline
Guideline:
OECD Guideline 117 (Partition Coefficient (n-octanol / water), HPLC Method)
Deviations:
no
Qualifier:
according to guideline
Guideline:
EU Method A.8 (Partition Coefficient - HPLC Method)
Deviations:
no
GLP compliance:
yes
Type of method:
HPLC method
Analytical method:
high-performance liquid chromatography
Key result
Type:
log Pow
Partition coefficient:
ca. 2.45
Remarks on result:
other: The test was performed at approximately neutral pH. The HPLC column temperature was 30 °C.
Type:
Pow
Partition coefficient:
ca. 281
Remarks on result:
other: The test was performed at approximately neutral pH. The HPLC column temperature was 30 °C.

The retention times, capacity factor and log10 Pow value determined for the sample are shown in the following table:

 Injection

 Retention Time

(mins)

Capacity Factor

(k')

 Log10 k'  Log10 Pow
 1  6.618  3.625  0.5593  2.45
 2  6.613  3.621  0.5589  2.45

Mean log10 Pow: 2.45

Partition coefficient: 281

Conclusions:
The partition coefficient (n-octanol:water) of the test item has been determined to be 281, log10 Pow 2.45.
Executive summary:

Introduction


The partition coefficient of the test item was determined using a method designed to be meet the requirements of the following guidelines:


 



  • Method A.8 Partition Coefficient of Commission Regulation (EC) No. 440/2008 of 30 May 2008

  • Method 117 of the OECD Guidelines for Testing of Chemicals, 13 April 2004


 


 


Method


The test system consisted of a high-performance liquid chromatograph with an appropriate detector. A reverse phase HPLC column with a very low percentage of polar groups was used and the mobile phase contained at least 25% aqueous phase.


 


The partition coefficent was determined by reference to a calibration curve plotted against reference standards.


 


Result and Conclusion


The partition coefficient (n-octanol:water) of the test item has been determined to be 281, log10 Pow 2.45.

Description of key information

Partition coefficient data summary.

Key value for chemical safety assessment

Log Kow (Log Pow):
2.45

Additional information

The partition coefficient (n-octanol:water) of the test item has been determined to be 281, log10 Pow 2.45.