Registration Dossier

Diss Factsheets

Physical & Chemical properties

Vapour pressure

Currently viewing:

Administrative data

Link to relevant study record(s)

Description of key information

Waiving

Key value for chemical safety assessment

Additional information

According to the REACH Regulation (EC n. 1907/2006), Annex VII, Column 2, the study does not need to be conducted if the melting point is above 300 °C.


The DSC analysis did not showed the presence of any oxothermic event up to 250°C. The broad endothermic event starting from room temperature to about 140°C could be attributed to water or solvent desorption, therefore, the study does not have to be performed