Registration Dossier

Diss Factsheets

Administrative data

First-aid measures

Emergency measure - Inhalation: Remove exposed person to fresh air if adverse effects are

observed.

Emergency measure - Eyes: Rinse with water for at least 15 minutes. Seek medical

attention if irritation develops or persists.

Emergency measure - Skin: Wash with soap and water. Seek medical attention if

irritation develops.

Launder contaminated clothing before use.

Emergency measure - Ingestion: Do not induce vomiting. Give two glasses of water if the

person is conscious. Seek immediate medical attention,

symptomatic treatment.

Fire-fighting measures

Recommended extinguishing agent: Carbon dioxide, dry chemical, alcohol foam or water spray

are suitable extinguishing agents. Do not use water-jet,

splattering may occur.

Product arising from burning: Combustion products may contain carbon and nitrogen oxides,

together with some soot, oxides of copper and aldehydes.

Product determined by test: N

Protective equipment: A self-contained breathing apparatus should be worn.

Accidental release measures

Emergency measures in case of spillage: Wear personal protective equipment when cleaning spillages

(cf 2.3.1). Ventilate the area if spillage is in a confined

space.

Prevent entry of spilt material into sewers and water-

courses. Dispose of waste by incineration.

Handling and storage

Handling: Observe the usual procedures in handling organic chemicals.

Wear nitrile or neoprene gloves and chemical goggles.

Storage: Use local exhaust ventilation in store-rooms.

Transport information

Shippingopen allclose all
SpecialProvisionsopen allclose all
Shippingopen allclose all
Remarksopen allclose all

Marine transport (UN RTDG/IMDG)

Shippingopen allclose all
Remarksopen allclose all

Air transport (UN RTDG/ICAO/IATA)

Shippingopen allclose all
Special provisions / remarks
Remarks:
Transport: No special precautions.
SpecialProvisionsopen allclose all

Exposure controls / personal protection

Stability and reactivity

Danger other than fire: None reported.

Chemical reaction with water: None reported.

Disposal considerations

Industry - Possibility of recovery/recycling: Recovery for reuse is not feasible.

Industry - Possibility of neutralisation: No method of neutralisation is known.

Industry - Possibility of destruction: controlled discharge: Not recommended.

Industry - Possibility of destruction - incineration: Recommended method of disposal. Ensure that waste gas

treatment to remove oxides of nitrogen and copper oxides is

used. (A661)

Industry - Possibility of destruction - water purification: Not recommended.

Public at large - Possibility of recovery/recycling: Recovery fron fuel is not possible in view of the low

concentrations of substance.

Public at large - Possibility of neutralisation: Hazardous effects will be due to the fuel, the substance

will be present at such a low level that its hazardous

properties will not be observable.

Public at large - Possibility of destruction: controlled discharge: Dispose of as for waste fuel.