Administrative data

Endpoint:
flash point of flammable liquids
Type of information:
experimental study
Adequacy of study:
key study
Study period:
From February 28, 2019 to April 18, 2019
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
2019
Report date:
2019

Materials and methods

Test guideline
Qualifier:
according to guideline
Guideline:
other: HJ/T 153-2004 "EU Regulation on the Testing Methods for REACH". A.9
GLP compliance:
yes (incl. QA statement)
Type of method:
equilibrium method closed cup

Test material

Constituent 1
Reference substance name:
Sulfonic Acids, C18-alkane hydroxyl and C18-alkene, potassium salts
Cas Number:
2210238-56-3
IUPAC Name:
Sulfonic Acids, C18-alkane hydroxyl and C18-alkene, potassium salts
Test material form:
solid
Remarks:
Color: White to pale yellow This sample was obtained from the original liquid form by removing water.
Specific details on test material used for the study:
-Storage conditions
Store container tightly closed in well-ventilated place. Store in corrosive resistant container with a resistant inliner. Store locked up. Don't store with acids.

-Test item stability under storage conditions
Stable in container after opening. Stable in water and in light. Stability in soil is not applicable.

Results and discussion

Flash point
Key result
Flash point:
> 200 °C
Remarks on result:
other: The test failed to conduct by flash point in liquid sample, measuring range for flash point instrument with automatic closing function in lab between room temperature to 200℃ , it was unable to melt test substance of 231.3℃ melting point.

Applicant's summary and conclusion

Interpretation of results:
GHS criteria not met
Conclusions:
The test failed to conduct by flash point in liquid sample, measuring range for flash point instrument with automatic closing function in lab between room temperature to 200℃ , it was unable to melt test substance of 231.3℃ melting point.
Executive summary:

-Objective
Determining the Flash point of C18K to provide data for environmental assessment.


 


-Test guideline


HJ/T 153-2004 "EU Regulation on the Testing Methods for REACH". A.9


 


-Flash point testing explanation


The test failed to conduct by flash point in liquid sample, measuring range for flash point instrument with automatic closing function in lab between room temperature to 200℃ , it was unable to melt test substance of 231.3℃ melting point.