Registration Dossier

Diss Factsheets

Administrative data

First-aid measures

Emergency measure - Inhalation: Move patient to fresh air. Symptomatic treatment.

Emergency measure - Eyes: Rinse immediately with plenty of water, also under the

eyelids, for at least 15 minutes. If symptoms persist, seek

medical attention.

Emergency measure - Skin: Wash off with soap and plenty of water. If skin irritation

persists, seek medical attention.

Emergency measure - Ingestion: Seek medical attention.

Fire-fighting measures

Recommended extinguishing agent: Water, water spray, dry chemical, dry powder, carbon dioxide

may be used

Product arising from burning: Products of combustion may contain oxides of carbon,

nitrogen, sulfur and hydrogen fluoride gas

Product determined by test: N

Protective equipment: Wear a self-contained breathing apparatus.

Accidental release measures

Emergency measures in case of spillage: Wear suitable protective clothing (see 2.1.1)

Sweep up spill and transfer to labelled containers. Dispose

of by incineration in accordance with local regulations.

Handling and storage

Handling: Provide appropriate exhaust ventilation at places where dust

is formed. Keep away from heat and sources of ignition. Use

personal protective equipment, dust mask, gloves, safety

goggles.

Storage: Store in tightly closed containers in a cool place.

Packaging of the substance and or preparation: 15.5" x 21" (40 x 54 cm), 200 weight construction

UN-approved fibre keg, externally painted mid-reen. It is

filled with a polyliner to 35 kg.

Transport information

Shippingopen allclose all
SpecialProvisionsopen allclose all
Shippingopen allclose all
Remarksopen allclose all

Marine transport (UN RTDG/IMDG)

Shippingopen allclose all
Remarksopen allclose all

Air transport (UN RTDG/ICAO/IATA)

Shippingopen allclose all
Special provisions / remarks
Remarks:
Transport code: UN 3077
Transport: ADR/RID class 9.

TREM-CARD 90 G 02 B packaging group III.

IMO, ICAO : not regulated.
SpecialProvisionsopen allclose all

Exposure controls / personal protection

Stability and reactivity

Danger other than fire: None reported.

Chemical reaction with water: None reported.

Dust explosion determined by test: N

Disposal considerations

Industry - Possibility of recovery/recycling: Recovery for recycling is not feasible

Industry - Possibility of neutralisation: None human

Industry - Possibility of destruction: controlled discharge: Not permitted.

Industry - Possibility of destruction - incineration: Recommended method at a suitable facility. Waste gas

treatment to remove oxides of nitrogen and sulfur and

hydrogen fluoride should be fitted. (A661)

Industry - Possibility of destruction - water purification: Not permitted.

Public at large - Possibility of recovery/recycling: The substance will not enter the public domain.