Administrative data

First-aid measures

Description of first aid measures:

Pay attention to self-protection.

Remove victims from hazardous area.

Immediately remove soiled or soaked clothing and remove it to a safe distance.

Keep victim warm, in a stabilized position and covered.

Do not leave victims unattended.

If the casualty is unconscious: Place the victim in the recovery position.

Inhalation:

Potential for exposure by inhalation if dusts or smoke are generated.

Move victims into fresh air.

With labored breathing: Provide with oxygen. Consult a doctor.

If the casualty is not breathing: Perform mouth-to-mouth resuscitation, notify emergency physician immediately.

Skin contact:

Wash off affected area immediately with plenty of water for at least 15 minutes.

If symptoms persist, consult a physician for treatment.

Eye contact:

With eye held open, thoroughly rinse immediately with plenty of water for at least 10 minutes.

Consult an ophthalmologist immediately if the symptoms persist.

Ingestion:

Rinse out mouth.

Immediately give large quantities of water to drink.

Consult a physician immediately.

Most important symptoms and effects, both acute and delayed:

Indication of any immediate medical attention and special treatment needed:

The initial focus is only on the local action, possibly characterized by a progressive tissue irritation.

In the eye, irritating solids cause, depending on the intensity of exposure, irritation of the conjunctiva and, in exceptional cases, damage to the cornea.

There is a danger of blindness if corneas are damaged!

Superficial irritations and only infrequent damage with ulcerations develop on the skin.

Fire-fighting measures

Extinguishing media:

Suitable extinguishing media:

All extinguishing substances suitable.

Unsuitable extinguishing media:

Do not use a solid water stream as it may scatter and spread fire.

Special hazards arising from the substance or mixture:

In the case of fire, the following hazardous smoke fumes may be produced: carbon dioxide nitric oxides.

Advice for firefighters:

Take precautionary measures against static discharges.

Use water spray to cool unopened containers.

Fire residues should be disposed of in accordance with the regulations.

Contaminated extinguishing water must be treated at a suitable disposal plant in accordance with waste management laws.

In case of fire, remove the endangered containers and bring to a safe place, if this can be done safely.

Keep out unprotected persons.

In the event of fire, wear self-contained breathing apparatus.

Full protective suit.

Accidental release measures

Personal precautions, protective equipment and emergency procedures:

Avoid dust formation.

Wear personal protective equipment.

Keep unauthorized persons away.

Environmental precautions:

Prevent substance from entering soil, natural bodies of water and sewer systems.

If the product contaminates rivers and lakes or drains inform respective authorities.

Methods and material for containment and cleaning up:

Pick up mechanically.

Collect in suitable containers.

Dispose of absorbed material in accordance with the regulations.

Pack and label wastes like the pure substance.

Do not detach label from the delivery containers prior to disposal.

To absorb spilled substance an approved industrial vacuum cleaner is recommended.

If necessary, the spilled substance should be moistened.

Handling and storage

Precautions for safe handling:

Use permissible in closed systems only.

Handle and transfer product in closed systems only (gas displacement device).

Ensure that apparatus and pipelines are free from leaks.

Do not ventilate into the open.

Dedicated loading/unloading stations required.

Empty, clean and dry system / system components completely before maintenance and repair work is done.

Written approval necessary in case of non-routine jobs, e.g. maintenance activities.

Wear personal protective equipment.

Conditions for safe storage, including any incompatibilities:

Advice on protection against fire and explosion:

Take precautionary measures against static discharges.

Avoid dust formation.

Further information: VDI 2263 "Dust fires and dust explosions; dangers, evaluation, preventive measures."

Normal measures for preventive fire protection.

Storage:

Store in the original receptacle, keeping this tightly sealed, under cool and dry conditions.

Further information:

Protect from sunlight, warmth and heat.

In order to ensure due transportation, make certain that stacks are of the correct height, containers are securely fastened so as not to fall off, and labelled according to the regulations.

Advice on common storage:

No special precautions required.

Transport information

Land transport (UN RTDG/ADR/RID)

Shippingopen allclose all
Special provisions / remarks
Remarks:
Not classified as dangerous in the meaning of transport regulations.

Inland waterway transport (UN RTDG/ADN(R))

Shippingopen allclose all
Special provisions / remarks
Remarks:
Not classified as dangerous in the meaning of transport regulations.

Marine transport (UN RTDG/IMDG)

Shippingopen allclose all
Special provisions / remarks
Remarks:
Not classified as dangerous in the meaning of transport regulations.

Air transport (UN RTDG/ICAO/IATA)

Shippingopen allclose all
Special provisions / remarks
Remarks:
Not classified as dangerous in the meaning of transport regulations.
SpecialProvisionsopen allclose all

Exposure controls / personal protection

Control parameters:

DNEL/DMEL values:

Remarks: No substance-related safety assessment is necessary / has been conducted for this product.

PNEC values:

Remarks: No substance-related safety assessment is necessary / has been conducted for this product.

Exposure controls:

Engineering measures:

Take precautionary measures against static discharges.

Refill and handle product only in closed system.

Wastewater can be added to a biological wastewater treatment plant.

Minimization of emissions by means of suitable technical measures such as flanges and valves with low leakage rates, recirculation of vapours.

All precautionary measures indicated have to be observed.

The substance must be handled under strictly controlled conditions in accordance with Article 17/18 of the REACH regulation.

Personal protective equipment:

Respiratory protection:

Accidental release measures:

Respiratory protective equipment independent of surrounding air or Local ventilation.

Hand protection:

Glove material: Nitrile, for example: Dermatril 740, Kächele-Cama Latex GmbH (KCL), Germany

Material thickness: 0.11 mm

Method: DIN EN 374.

Accidental release measures:

Glove material:       Nitrile/Chloroprene, for example, Nitopren 717, Kächele-Cama Latex GmbH (KCL), Germany

Material thickness: 0.65 mm

Method: DIN EN 374.

Eye protection:

Safety glasses with side-shields conforming to EN166.

Accidental release measures:

Goggles

Skin and body protection:

Select materials and equipment for physical protection depending on the concentration and volume of hazardous substances and the workplace involved.

Hygiene measures:

Do not eat, drink, smoke, or sniff while at work.

Wash your hands and/or face before breaks and before termination of work.

Avoid contact with skin and eyes.

Cleanse and apply cream to skin after work.

Take off clothing and shoes contaminated with product.

Clean before reuse.

Protective measures:

All precautionary measures indicated have to be observed.

Risk assessment and risk monitoring of all work places required.

Regular safety training is a must.

Health, Safety and Emergency Management System recommended.

Written approval necessary in case of non-routine jobs, e.g. maintenance activities.

The personal protective equipment used must meet the requirements of directive 89/686/EEC and amendments (CE certification).

Stability and reactivity

Reactivity:

No further information available.

Chemical stability:

No further information available.

Possibility of hazardous reactions:

No hazardous reactions are known if properly handled and stored.

Conditions to avoid:

No further information available.

Incompatible materials:

None.

Hazardous decomposition products:

None.

Disposal considerations

Waste treatment methods:

Product:

Strictly controlled conditions during disposal or treatment to air, wastewater and waste.

Wastewater can be added to a biological wastewater treatment plant.

Bring wastewater containing AOX for professional disposal.

Bring used exhaust air filter for incineration.

Disposal according to local authority regulations.

The waste key number must be determined as per the European Waste Types List (decision on EU Waste Types List 2000/532/EC) in cooperation with the disposal firm / producing firm / official authority.

Uncleaned packaging:

Do not reuse empty containers and dispose of in accordance with the regulations issued by the appropriate local authorities.