Registration Dossier

Physical & Chemical properties

Flash point

Currently viewing:

Administrative data

Link to relevant study record(s)

Description of key information

The Pensky-Martens closed cup method was applied for the determination of the flash-point of R-2F-Pr-Me.
The flash-point of the test substance was 25°C.
The atmospheric pressure was 1020 hPa.

Key value for chemical safety assessment

Flash point at 101 325 Pa:
25 °C

Additional information

The Pensky-Martens closed cup method was applied for the determination of the flash-point of R-2F-Pr-Me. The flash-point of the test substance was 25°C. The atmospheric pressure was 1020 hPa. With accofdance with annex I, 2.6. in the regulation (EC) No. 1272/2008 (CLP regulation), R-2F-Pr-Me is classified as Flammable liquids class 3.