Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Physical & Chemical properties

Partition coefficient

Currently viewing:

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
partition coefficient
Type of information:
experimental study
Adequacy of study:
key study
Study period:
Experimental Starting Date: 03 December 2013; Experimental Completion Date: 10 March 2014
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study
Remarks:
Study conducted in compliance with agreed protocols, with no or minor deviations from standard test guidelines and/or minor methodological deficiencies, which do not affect the quality of the relevant results. The study report was conclusive, done to a valid guideline and the study was conducted under GLP conditions.
Qualifier:
according to guideline
Guideline:
EU Method A.8 (Partition Coefficient)
Deviations:
no
Qualifier:
according to guideline
Guideline:
OECD Guideline 117 (Partition Coefficient (n-octanol / water), HPLC Method)
Deviations:
no
GLP compliance:
yes
Type of method:
HPLC method
Partition coefficient type:
octanol-water
Analytical method:
high-performance liquid chromatography
Key result
Type:
log Pow
Partition coefficient:
>= 5.57 - <= 6.62
Temp.:
35 °C
pH:
7.33

Results

Preliminary estimate

Approximate solubility in n-octanol: greater than 1.00 x 105 mg/L

Approximate solubility in water:       less than 10.6 mg/L

Approximate partition coefficient:    greater than 9.47 x 103(log Pow> 3.98)

Definitive test

Please see Attachment 2 for the Typical Chromatography.

Calibration

 

The dead time and the retention times, capacity factors (k) and log10Pow values for the reference standards are shown in the following tables:

Table 3.10

 

Dead Time

Retention Time (min)

Mean Retention Time (min)

Injection 1

Injection 2

Formamide

1.686

1.688

1.687

 

Table 3.11

 

Standard

Retention Time (min)

Mean Retention Time (min)

Capacity Factor (k)

log10k

log10Pow

Injection 1

Injection 2

Hexane

4.655

4.652

4.654

1.76

0.245

3.90

Heptane

5.324

5.320

5.322

2.15

0.333

4.66

Octane

6.129

6.128

6.129

2.63

0.420

5.18

Nonane

7.124

7.121

7.123

3.22

0.508

5.65

Dodecane

11.575

11.568

11.572

5.86

0.768

6.10

Tetradecane

16.319

16.319

16.319

8.67

0.938

7.20

Partition coefficient of sample

 

The retention times, capacity factors and log10Pow values determined for the sample are shown in the following table:

 

Table 3.12

 

Peak

Injection

Retention Time (mins)

Capacity Factor (k′)

log10k′

log10Pow

Mean log10Pow

Pow

Mean Area%

1

1

7.842

3.65

0.562

5.57

5.57

3.69 x 105

2.25

2

7.843

3.65

0.562

5.57

2

1

8.322

3.93

0.595

5.71

5.71

5.15 x 105

9.41

2

8.324

3.93

0.595

5.71

3

1

9.040

4.36

0.639

5.91

5.91

8.10 x 105

16.8

2

9.032

4.35

0.639

5.91

4

1

9.779

4.80

0.681

6.09

6.09

1.24 x 106

25.1

2

9.779

4.80

0.681

6.09

5

1

10.521

5.24

0.719

6.26

6.27

1.85 x 106

25.4

2

10.548

5.25

0.720

6.27

6

1

11.535

5.84

0.766

6.47

6.47

2.98 x 106

15.7

2

11.537

5.84

0.766

6.47

7

1

12.289

6.28

0.798

6.62

6.62

4.1 x 106

5.28

2

12.297

6.29

0.799

6.62

 

Overall log10Pow:      5.57 to 6.62

Partition coefficient:  3.69 x 105 to 4.13 x 106  

Conclusions:
Please see the Executive Summary for the Conclusion.
Executive summary:

The determination was carried out using the HPLC Method designed to be compatible with Method A8 Partition Coefficient of Commission Regulation (EC) No 440/2008 of 30 May 2008 and Method 117 of the OECD Guidelines for Testing of Chemicals, 13 April 2004.

 

The test system consisted of a high performance liquid chromatograph with a suitable detector. A reverse phase HPLC column with a very low percentage of polar groups was used (e.g. C8, C18). The mobile phase contained at least 25% aqueous phase.

 

Conclusion

The partition coefficient of the test item has been determined to be in the range 3.69 x 105 to 4.13 x 106 (log10 Pow 5.57 to 6.62).

Description of key information

Log Kow (constituents of the substance): ≥5.57 to ≤6.62 at 35°C and pH 7.3 (measured)

Log Kow (constituents): 5.11 - 7.22 at 20°C (QSAR)

Key value for chemical safety assessment

Additional information

The substance is a hydrocarbon UVCB. Standard tests for this endpoint are intended for single substances and are not appropriate for this complex substance. However, this endpoint is characterised using quantitative structure property relationships for representative hydrocarbon structures that comprise the hydrocarbon blocks used to assess the environmental risk of this substance with QSAR software (see IUCLID Section 13).

The log Kow of the constituents of the substance have been determined using the HPLC method in accordance with OECD 117 Test Method and in compliance with GLP. The partition coefficient of the substance was determined to be in the range ≥3.69 x 105 to ≤4.13 x 106 (log10 Pow  ≥5.57 to ≤6.62) at 35°C and pH 7.3. The result was considered to be reliable but the results are not useful for chemical safety assessment.

As supporting information, the log Kow for individual constituents of Hydrocarbons, C10-C13, n-alkanes, isoalkanes, <2% aromatics have been predicted using a validated QSAR estimation method. The prediction method uses a fragment method and log Kow increases with increasing carbon number. The individual constituents of the substance have predicted log Kow values in the range 5.11 - 7.22 at 20°C.