Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Ecotoxicological information

Toxicity to microorganisms

Currently viewing:

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
activated sludge respiration inhibition testing
Type of information:
experimental study
Adequacy of study:
key study
Study period:
from 1981-11-13 to 1981-11-25
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study
Qualifier:
according to guideline
Guideline:
OECD Guideline 209 (Activated Sludge, Respiration Inhibition Test
Qualifier:
according to guideline
Guideline:
EU Method C.11 (Biodegradation: Activated Sludge Respiration Inhibition Test)
Version / remarks:
RICHTLINIE 88/302/EWG (TEIL C), EG AMTSBLATT L 133/118 "BELEBTSCHLAMM: PRÜFUNG DER ATMUNGSHEMMUNG"
Deviations:
yes
Remarks:
Test volume 200 mL instead of 500 mL
GLP compliance:
yes
Analytical monitoring:
no
Vehicle:
no
Details on test solutions:
- Concentrations: Stock solution 2 g/L
- Method: The test solution concentrations were performed dy dilution of the stock solution (Test concentrations: 500 and 1000 ppm (mg/L))
- Controls: blank control perfomed with the test solution without test substance and positive control performed with the reference substance 3,5 dichlorophenol.
- Evidence of undissolved material: no
Test organisms (species):
activated sludge
Details on inoculum:
- Laboratory culture: Municipal wastewater treatment plant in Frankfurt-Sindlingen
- Initial biomass concentration: Sludge Dry weight: 100 g of wet sludge in a 4.47 L (22.37 g/L)
Test type:
static
Water media type:
freshwater
Limit test:
no
Total exposure duration:
3 h
Test temperature:
20 ± 1 °C
pH:
7
Salinity:
-
Nominal and measured concentrations:
Nominal concentrations: 0 (control) 500 and 1000 mg/L
Measured concentrations: No concentrations were measured.

Positive control: Nominal concentrations:
5, 20 , 30 mg/L
Details on test conditions:
TEST SYSTEM
- Type: closed
- Aeration: no
- No. of vessels per concentration (replicates): 2
- No. of vessels per control (replicates): 1
- No. of vessels per vehicle control (replicates): 1

TEST MEDIUM / WATER PARAMETERS
- Source/preparation of dilution water: performed as follows:
90 mL of standard mud
+ 6.5 mL of synthetic wastewater
+ 3.5 mL of distilled water.
+ 100 mL of diluted test

Reference substance (positive control):
yes
Remarks:
3,5 dichlorophenol
Duration:
3 h
Dose descriptor:
NOEC
Effect conc.:
> 1 000 mg/L
Nominal / measured:
nominal
Conc. based on:
test mat.
Basis for effect:
inhibition of total respiration
Remarks:
respiration rate
Key result
Duration:
3 h
Dose descriptor:
EC50
Effect conc.:
> 1 000 mg/L
Nominal / measured:
nominal
Conc. based on:
test mat.
Basis for effect:
inhibition of total respiration
Remarks:
respiration rate
Remarks on result:
other: >> 1000
Duration:
3 h
Dose descriptor:
other: EC80
Effect conc.:
> 1 000 mg/L
Nominal / measured:
nominal
Conc. based on:
test mat.
Basis for effect:
inhibition of total respiration
Remarks:
respiration rate
Remarks on result:
other: >> 1000
Details on results:
The toxicity of Reactive Orange 72/78 on bacteria ("bacterial toxicity") was investigated in the oxygen-consumption inhibition test ("Robra test") with activated sludge as inoculum. After 3 hours the NOEC and the EC50 were determined to be greater than 1000 mg/L.
Results with reference substance (positive control):
The EC50 - value of the reference substance was determined to be < 20 mg/L.

Table 1: Inhibition of the respiration rate

mg/L Activity (mg O2/L x h) respiration/inhibition mean
control 1 39  - 40.5
control 2 42  - 40.5
control 3 40.5  - 40.5
positive control (5) 24 40.7  -
positive control (20) 15 63  -
positive control (30) 13.5 66.7  -
1000 (A) 43.5 -7.4 -9.3
1000 (B) 45 -11.1 -9.3
500 (A) 42 -3.7 -1.9
500 (B) 40.5 0 -1.9

Validity criteria:

The audit was completed without problems, the EC50 - value of the reference substance was 5 to 30 mg / L. The deviation of the controls remained below the limit of 15%.

Validity criteria fulfilled:
yes
Conclusions:
The inhibition rate of oxygen consumption after 3 hours of exposure of bacteria to the test item gave the following results:
EC50: >> 1000 mg/L , NOEC (EC20): >1000 mg/L , EC 80: >> 1000 mg/L
Executive summary:

The toxicity of Reactive Orange 72/78 on bacteria ("bacterial toxicity") was investigated in the oxygen-consumption inhibition test ("Robra test") with activated sludge from municipal wastewater biological treatment Frankfurt / M - Sindlingen as inoculum. The provision of the inhibition rate of oxygen consumption after 3 hours of exposure to the test item on bacteria test gave the following results:  

Median inhibitory concentration, EC50: >> 1000 mg/L

NOEC, EC20 : >1000 mg/L

EC 80: >> 1000 mg/L

Description of key information

After 3 hours the EC 50 was determined to be greater than 1000 mg/L.

Key value for chemical safety assessment

EC10 or NOEC for microorganisms:
1 000 mg/L

Additional information

The toxicity of Reactive Orange 72/78 on bacteria ("bacterial toxicity") was investigated in the oxygen-consumption inhibition test ("Robra test") with activated sludge from municipal wastewater biological treatment Frankfurt / M - Sindlingen as inoculum. The provision of the inhibition rate of oxygen consumption after 3 hours of exposure to the test item on bacteria test gave the following results: 

Median inhibitory concentration, EC50: >> 1000 mg/L

NOEC, EC20 : >1000 mg/L

EC80: >> 1000 mg/L