First-aid measures

Protect yourself and any casualty from further exposure during decontamination.  Wear suitable protective clothing, gloves and eye/face protection.

Remove contaminated clothing.

Inhalation: Remove persons affected by vapour to fresh air.  Keep patient at rest and give oxygen if breathing difficult.  Apply artificial respiration if necessary (do not employ mouth-to-mouth method).  Appropriate mechanical means should be used (Pneupac or bag and mask).  Seek medical treatment.

Skin Contact: Wash affected skin with plenty of water.  Seek medical treatment.

Eye Contact: Irrigate with eyewash solution or clean water, holding the eyelids apart, for at least 15 minutes.  Seek medical treatment.

Ingestion: If swallowed, rinse mouth with water (only if the person is conscious).   Do not induce vomiting.  Keep patient at rest.  Seek medical treatment.

Other: May cause irritation to skin, eyes and respiratory system.  Seek medical treatment when anyone has symptoms apparently due to swallowing, inhalation or contact with skin or eyes.

Fire-fighting measures

Extinguishing media: Water spray, foam, dry powder or CO2.  Water spray should be used to cool containers.

Advice for Firfighters: A self contained breathing apparatus and suitable protective clothing should be worn in fire conditions.  Prevent substance entering sewers.

Accidental release measures

Ensure suitable personal protection (including respiratory protection) during removal of spillages.

Avoid release to the environment.  Prevent liquid entering watercourses and sewers.

Eliminate sources of ignition.  Evacuate area.  Use only non-sparking tools.  Provided it is safe to do so, isolate the source of the leak.  Contain and adsorb large spillages onto an inert, non flammable adsorbent carrier.  Transfer to a container for disposal.

Handling and storage

Use only in well-ventilated areas.  Avoid contact with skin, eyes or clothing.   Use non-sparking hand tools and explosion proof electrical equipment.Keep away from sources of ignition.  Take precautionary measures against static discharge.   Wear suitable protective clothing.

Keep container tightly closed, in a cool, well ventilated place.  Keep container dry.   Keep containers properly sealed when not in use.  

Keep in a cool place.

Keep only in original container.

Transport information

Land transport (UN RTDG/ADR/RID)

UN number:
UN2920
Shipping information
Proper shipping name and description:
CORROSIVE LIQUID, FLAMMABLE N.O.S
Chemical name:
Ethyl 2- bromobutyrate
Language:
English
Labels:
8 + 3
SpecialProvisionsopen allclose all
Shippingopen allclose all
Remarksopen allclose all

Marine transport (UN RTDG/IMDG)

UN number:
UN2920
Shipping information
Proper shipping name and description:
CORROSIVE LIQUID, FLAMMABLE N.O.S (Ethyl 2- bromobutyrate)
Chemical name:
Ethyl 2- bromobutyrate
Labels:
8 + 3
Remarksopen allclose all

Air transport (UN RTDG/ICAO/IATA)

UN number:
UN2920
Shipping information
Proper shipping name and description:
CORROSIVE LIQUID, FLAMMABLE N.O.S (Ethyl 2- bromobutyrate)
Chemical name:
Ethyl 2- bromobutyrate
Labels:
8 + 3
Remarksopen allclose all
SpecialProvisionsopen allclose all

Exposure controls / personal protection

1. Technical protection measures

2. Organisational protection measures: Stated in company Quality, Environment and safety Management System

3. Hand protection : Neoprene gloves.

4. Feet protection: Safety boots.

5. Body protection: Chemical protection suit.

6. Eye protection: Goggles

7. Respiratory protection: Where engineering controls are not fitted or inadequate wear suitable respiratory protective equipment.

Stability and reactivity

Stable under normal conditions.

Protect from light.  

Keep away from heat and sources of ignition.

Do not mix with acids, bases, oxidizing and reducing agents.

Disposal considerations

Dispose of this material and its container to hazardous or special waste collection point.  Disposal may be carried out by diluting the waste with a suitable solvent and burning under controlled conditions at a licensed waste material processor; stack gases will need to be scrubbed (See Section 5 above).