Registration Dossier

Diss Factsheets

Physical & Chemical properties

Flash point

Currently viewing:

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
flash point of flammable liquids
Type of information:
experimental study
Adequacy of study:
key study
Study period:
2007-10-12
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study
Qualifier:
according to guideline
Guideline:
EU Method A.9 (Flash-Point)
Version / remarks:
year of the guideline: 1996
Deviations:
no
GLP compliance:
yes (incl. QA statement)
Type of method:
equilibrium method closed cup
Flash point apparatus:
Setaflash apparatus
Key result
Flash point:
66.75 °C
Atm. press.:
102.41 kPa
Interpretation of results:
GHS criteria not met
Conclusions:
The flash point of Incozol 3 was determined to be 67 ± 2 °C.
Executive summary:

The flash point of Incozol 3 was determined according to Commission Directive 92/69/EEC method A.9 using the equilibrium method closed cup. The flash point of Incozol 3 was determined to be 66.75 °C at 102.41 kPa.

Description of key information

The flash point of Incozol 3 has been determined to be 67 ± 2 °C.

Key value for chemical safety assessment

Flash point at 101 325 Pa:
67 °C

Additional information

A study was conducted according to Commission Directive 92/69/EEC method A.9 using the equilibrium method closed cup. The flash point of Incozol 3 was determined to be 66.75 °C at 102.41 kPa.