Administrative data

Endpoint:
melting point/freezing point
Type of information:
experimental study
Adequacy of study:
key study
Study period:
Study experimental phase 2012-11-13 to 2013-01-22
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
other: Meets the criteria for classification as reliable without restriction according to Klimisch et al (1997).

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
2013
Report date:
2013

Materials and methods

Test guideline
Qualifier:
according to guideline
Guideline:
OECD Guideline 102 (Melting point / Melting Range)
Deviations:
no
GLP compliance:
yes
Type of method:
other: Buchi Melting Point B545 apparatus

Test material

Constituent 1
Chemical structure
Reference substance name:
tetrasodium 1,8,15,22-tetra-(3-sulfoxypropylsulfonyl)copper phthalocyanine
EC Number:
696-145-8
Cas Number:
944730-39-6
Molecular formula:
C44H36CuN8O20S8 .4Na
IUPAC Name:
tetrasodium 1,8,15,22-tetra-(3-sulfoxypropylsulfonyl)copper phthalocyanine
Test material form:
solid: particulate/powder
Remarks:
migrated information: powder

Results and discussion

Melting / freezing point
Melting / freezing pt.:
> 300 °C
Remarks on result:
other: Examination by capillary method resulted in no obvious melt being observed.

Applicant's summary and conclusion

Conclusions:
Examination by capillary method resulted in no melt being observed. Therefore the melting point was recorded as >300ºC.
Executive summary:

Introduction

This study was undertaken to determine the melting point of the test material. The melting point was determined according to OECD Guideline 102.

Results & Conclusions

Examination by capillary method resulted in no melt being observed. Therefore the melting point was recorded as >300ºC.