Registration Dossier

Guidance on Safe Use

Guidance on Safe Use

Currently viewing:

Administrative data

First-aid measures

Emergency measure - Inhalation: Supply fresh air.

Consult a doctor in case of symptoms.
Emergency measure - Eyes: Rinse opened eye for several minutes under running water.
Emergency measure - Skin: Irritant.

Rinse with plenty of water and soap.

Take away contaminated clothes.

Call for a doctor.
Emergency measure - Ingestion: Avoid vomiting. Call for a doctor.

Fire-fighting measures

Recommended extinguishing agent: Water haze; foam; carbon dioxide; chemical powder.

Product arising from burning: Water, carbon dioxide and monoxide.

Product determined by test: N

Protective equipment: Put on rubber gloves and dust mask. Safety shoes and eye
protection is adviceable.

Accidental release measures

Emergency measures in case of spillage: Do not allow to enter dreinage system, surface or ground
water.

Collect spill with a proper absorbent.

Handling and storage

Handling: Use protective clothing.

Do not let the product enter the sewers.

Storage: No smoking.

Safe electrical equipment.

Ground all equipment.

No free flames.

Packaging of the substance and or preparation: Metallic drums (170 liter).

Transport information

Shippingopen allclose all
SpecialProvisionsopen allclose all
Shippingopen allclose all
Remarksopen allclose all

Marine transport (IMDG)

Remarksopen allclose all

Air transport ICAO/IATA

Remarks
Transport code: Class 9 - UN 3082
Transport: Designation of goods: Environmentally hazardous substance,
liquid, n.o.s. (2-isopropyl-2-isobutyl-1,3-dimethoxypropane)
SpecialProvisionsopen allclose all

Exposure controls / personal protection

Stability and reactivity

Danger other than fire: None.

Chemical reaction with water: None.

Dust explosion: Not applicable.

Dust explosion determined by test: N

Disposal considerations

Industry - Possibility of recovery/recycling: The product is an intermediate of a catalytic system. There
is no recovery or recycling for the catalyst.

Industry - Possibility of neutralisation: Not required.

Industry - Possibility of destruction: controlled discharge: Yes.

Do not dispose with domestic waste.

Industry - Possibility of destruction - incineration: Yes.

Industry - Possibility of destruction - water purification: Yes.

Public at large - Possibility of recovery/recycling: It will not be put on contact with public as such, therefore
no recovery or recycling is foreseen.

Public at large - Possibility of neutralisation: Not applicable.

Public at large - Possibility of destruction: controlled discharge: Not applicable.

Public at large - Possibility of destruction - incineration: Not applicable.

Public at large - Possibility of destruction - water purification: Not applcable.