Registration Dossier
Registration Dossier
Data platform availability banner - registered substances factsheets
Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.
The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.
Diss Factsheets
Use of this information is subject to copyright laws and may require the permission of the owner of the information, as described in the ECHA Legal Notice.
EC number: 428-100-3 | CAS number: 94239-04-0
- Life Cycle description
- Uses advised against
- Endpoint summary
- Appearance / physical state / colour
- Melting point / freezing point
- Boiling point
- Density
- Particle size distribution (Granulometry)
- Vapour pressure
- Partition coefficient
- Water solubility
- Solubility in organic solvents / fat solubility
- Surface tension
- Flash point
- Auto flammability
- Flammability
- Explosiveness
- Oxidising properties
- Oxidation reduction potential
- Stability in organic solvents and identity of relevant degradation products
- Storage stability and reactivity towards container material
- Stability: thermal, sunlight, metals
- pH
- Dissociation constant
- Viscosity
- Additional physico-chemical information
- Additional physico-chemical properties of nanomaterials
- Nanomaterial agglomeration / aggregation
- Nanomaterial crystalline phase
- Nanomaterial crystallite and grain size
- Nanomaterial aspect ratio / shape
- Nanomaterial specific surface area
- Nanomaterial Zeta potential
- Nanomaterial surface chemistry
- Nanomaterial dustiness
- Nanomaterial porosity
- Nanomaterial pour density
- Nanomaterial photocatalytic activity
- Nanomaterial radical formation potential
- Nanomaterial catalytic activity
- Endpoint summary
- Stability
- Biodegradation
- Bioaccumulation
- Transport and distribution
- Environmental data
- Additional information on environmental fate and behaviour
- Ecotoxicological Summary
- Aquatic toxicity
- Endpoint summary
- Short-term toxicity to fish
- Long-term toxicity to fish
- Short-term toxicity to aquatic invertebrates
- Long-term toxicity to aquatic invertebrates
- Toxicity to aquatic algae and cyanobacteria
- Toxicity to aquatic plants other than algae
- Toxicity to microorganisms
- Endocrine disrupter testing in aquatic vertebrates – in vivo
- Toxicity to other aquatic organisms
- Sediment toxicity
- Terrestrial toxicity
- Biological effects monitoring
- Biotransformation and kinetics
- Additional ecotoxological information
- Toxicological Summary
- Toxicokinetics, metabolism and distribution
- Acute Toxicity
- Irritation / corrosion
- Sensitisation
- Repeated dose toxicity
- Genetic toxicity
- Carcinogenicity
- Toxicity to reproduction
- Specific investigations
- Exposure related observations in humans
- Toxic effects on livestock and pets
- Additional toxicological data
Administrative data
First-aid measures
Emergency measure - Inhalation: Remove patient from exposure.
Obtain medical attention if ill effects occur.
Emergency measure - Eyes: Irrigate with eyewash solution or clean water, holding the
eyelids apart for at least 15 minutes.
Obtain medical attention.
Emergency measure - Skin: Remove contaminated clothing. Wash skin with water.
If symptoms develop, obtain medical attention.
Emergency measure - Ingestion: Seek immediate medical attention.
Fire-fighting measures
Recommended extinguishing agent: Dry powder, foam or carbon dioxide.
Water spray should be used to cool containers.
Product arising from burning: Oxides of carbon and nitrogen together with hydrogen
fluoride and soot.
Product determined by test: N
Protective equipment: A self contained breathing apparatus and suitable protective
clothing should be worn.
Accidental release measures
Emergency measures in case of spillage: Ensure suitable personal protection (including respiratory
protection) during removal of spillages.
Eliminate sources of ignition.
Adsorb spillages onto sand, earth or any suitable adsorbent
material. Do not adsorb onto sawdust or other combustible
materials. Transfer to a container for disposal. Wash the
spillage area clean.
Do not allow to enter drains, sewers or watercourses.
Handling and storage
Handling: Use only in well ventilated areas.
Avoid contact with skin and eyes.
Do not breathe fumes/vapour.
Take precautionary measures against static discharges.
Keep away from heat, sources of ignition and direct
sunlight.
Storage: Keep container tightly closed, in a cool, well ventilated
place.
Keep away from heat, sources of ignition and direct
sunlight.
Packaging of the substance and or preparation: 316 stainless steel drums for semi-technical production in
2000.
316 stainless steel isotanks for full scale production on
2001 onwards.
Transport information
Shippingopen allclose all
SpecialProvisionsopen allclose all
Shippingopen allclose all
Remarksopen allclose all
Marine transport (UN RTDG/IMDG)
Shippingopen allclose all
Remarksopen allclose all
Air transport (UN RTDG/ICAO/IATA)
Shippingopen allclose all
Special provisions / remarks
- Remarks:
- Transport code: UN1993
Transport: Class 3, Packing Group III
Proper Shipping Name: Flammable Liquid, Toxic, N.O.S.
(2-fluoro-6-trifluoromethylpyridine)
SpecialProvisionsopen allclose all
Exposure controls / personal protection
Stability and reactivity
Danger other than fire: None reported.
Chemical reaction with water: None reported.
Dust explosion: Not applicable, the substance is a liquid.
Dust explosion determined by test: N
Disposal considerations
Industry - Possibility of recovery/recycling: Recovery is not possible.
Industry - Possibility of neutralisation: Not reported.
Industry - Possibility of destruction: controlled discharge: Not recommended.
Industry - Possibility of destruction - incineration: Incinerate above 1100 deg C with waste gas treatment to
remove nitrogen oxides and hydrogen fluoride.
Industry - Possibility of destruction - water purification: Not recommended in view of the low biodegradability of the
substance.
Public at large - Possibility of recovery/recycling: Substance will not enter the public domain.
Public at large - Possibility of neutralisation: Substance will not enter the public domain.
Public at large - Possibility of destruction: controlled discharge: Not applicable.
Public at large - Possibility of destruction - incineration: Not applicable.
Public at large - Possibility of destruction - water purification: Not applicable.
Public at large - Possibility of destruction - others: Not applicable.
Information on Registered Substances comes from registration dossiers which have been assigned a registration number. The assignment of a registration number does however not guarantee that the information in the dossier is correct or that the dossier is compliant with Regulation (EC) No 1907/2006 (the REACH Regulation). This information has not been reviewed or verified by the Agency or any other authority. The content is subject to change without prior notice.
Reproduction or further distribution of this information may be subject to copyright protection. Use of the information without obtaining the permission from the owner(s) of the respective information might violate the rights of the owner.