Administrative data

Endpoint:
pH
Type of information:
experimental study
Adequacy of study:
key study
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study
Justification for type of information:
Experimental test result performed using standard test guidelines

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
2022
Report date:
2021

Materials and methods

Test guideline
Qualifier:
according to guideline
Guideline:
OECD Guideline 122 (Determination of pH, Acidity and Alkalinity)
GLP compliance:
no

Test material

Constituent 1
Chemical structure
Reference substance name:
2-Butanamine, 1,1'-[(1-methylethylidene)bis(oxy)]bis-
Molecular formula:
C11H26N2O2
IUPAC Name:
2-Butanamine, 1,1'-[(1-methylethylidene)bis(oxy)]bis-
Test material form:
liquid
Details on test material:
- Name of the test material: 2-Butanamine, 1,1'-[(1-methylethylidene)bis(oxy)]bis-
- Common name: Recyclamine R 401
- Molecular formula: C11H26N2O2
- Molecular weight: 218.34 g/mol
- SMILES: CCC(N)COC(C)(C)OCC(N)CC
- InChI: 1/C11H26N2O2/c1-5-9(12)7-14-11(3,4)15-8-10(13)6-2/h9-10H,5-8,12-13H2,1-4H3
- Substance type: Organic
- Physical state: Liquid

Reagents

Reagent:
water

Results and discussion

pH value
Key result
pH value:
10.48
Temp.:
22.5 °C
Concentration:
1 vol%
Remarks on result:
other: No other detail available

Any other information on results incl. tables

Observation Table & Result :

The pH value of 1% aqueous Solution are recorded after one minute and two minutes, (and 10 minutes if required) at 22.2 °C .

 Method Details     Observations  Remarks if, any
 Guideline  OECD 122                   
 Method  Digital pH meter  
 Principle of Method  

The mean pH of an aqueous

solution or dispersion in water was

determined with a pH

measurement interface equipped

with an appropriate electrode

system.

 

 Temperature of 1% w/v

test dispersion

 

 22.2°C

 Mean pH (RESULT)

 

 10.48

 Inference

1. Acidic

2. Basic

3. Neutral

 basic

Applicant's summary and conclusion

Conclusions:
The pH of test substance is 10.48 at 22.5 deg C .
Executive summary:

The result of three observations was averaged to determine pH value for 1% aqueous solution/dispersion/emulsion depending on the solubility of test chemical.

Based on available data, experimental pH value for 1% aqueous solution of test substance was observed to be 10.48 at 22.2 °C ,inferring its  basic nature.