No burning or glowing over the length of the pile was observed the test item was classified as "not flammable".

Key value for chemical safety assessment

Flammability:
non flammable

Additional information

The flammability of the test item Slags, ferronickel-manufg./ Electric Furnace Slag/ Converter Slag was determined following EC method A.10.

A preliminary test was performed, but it showed no melting, burning or glowing spreaded over the length of the pile. After cooling the remaining residue the colour of the test item was unchanged. It was thus concluded that no main test will be performed and that the substance is considered "not flammable".

Justification for classification or non-classification

The flammability of the test item Slags, ferronickel-manufg./ Electric Furnace Slag/ Converter Slag was determined following EC method A.10.

It is concluded that Slags, ferronickel-manufg./Electric Furnace Slag/ Converter Slag are considered "not flammable" and do not have to be classified and have no obligatory labelling requirement for Flammability.