Physical & Chemical properties

Flash point

Currently viewing:

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
flash point
Type of information:
experimental study
Adequacy of study:
key study
Reliability:
1 (reliable without restriction)
Qualifier:
according to guideline
Guideline:
ISO No., other: as mentioned below
Principles of method if other than guideline:
The flash point of a flammable liquid is the lowest temperature at which there will be enough flammable vapor to ignite when an ignition source is applied by Closed cup method using Pensky-Martens Flash Point Apparatus.
GLP compliance:
not specified
Type of method:
closed cup
Flash point:
> 250 °C
Atm. press.:
977.9 hPa
Interpretation of results:
other: Not classified
Conclusions:
The flash point of test chemical is greater than 250°C at 977.9hPa.
Executive summary:

The flash point determination of test chemical was done following closed cup method using Pensky-Martens flash point apparatus. The test was conducted and flash point was found to be greater than 250°C at 977.9hPa.

Description of key information

The flash point determination of test chemical was done following closed cup method using Pensky-Martens flash point apparatus. The test was conducted and flash point was observed to be greater than 250°C at 977.9hPa.

Key value for chemical safety assessment

Flash point at 101 325 Pa:
250 °C

Additional information

The flash point determination of test chemical was done following closed cup method using Pensky-Martens flash point apparatus. The test was conducted and flash point was found to be greater than 250°C at 977.9hPa.