hazardous-waste-properties-ann-3-dir-2008-98

Waste Framework Directive, Annex III - Waste - Hazardous Properties

EU. Substances according to Hazardous Waste Properties: Annex III, Directive 2008/98/EC, 22 November 2008, amended by Directive 2018/851/EU, 14 June 2018

This list contains substances that have been assigned hazard property (HP) waste codes 1-15, as defined in terms of the hazard class and category, hazard (H) statement, and/or concentration limits provided in Annex III of the Waste Framework Directive 2008/98/EC. The classifications of the substances listed in the list are based on their harmonised classifications per Table 3 of Annex VI to the CLP Regulation 1272/2008/EC.

Last updated 26 April 2024. Database contains 4748 unique substances/entries.
Filter the list

A complex combination of hydrocarbons produced by the distillation of products from the catalytic cracking process. It consists of hydrocarbons having carbon numbers predominantly in the range of C3 through C5 and boiling in the range of approximately -48°C to 32°C (-54°F to 90°F).
270-071-2
68409-99-4
Flam. Gas 1
Carc. 1A
Muta. 1B
HP3 Flammable Waste (FW): (a)liq FW with flash pt <60°C or FW gas, diesel and light heating oils with flash pt >55°C and ≤75°C (b)pyrophoric liq/solid FW liable to ignite within 5 min after air contact (c)solid FW readily combustible or which may cause/contribute to fire by friction (d)gas FW which is F in air at 20°C and 101.3 kPa (e)water reactive FW which, in contact with water, emits F gases in dangerous quantities (f)other: aerosols, self-heating, organic peroxides and self-reactive FWs.
HP7 Carcinogenic: waste which induces cancer or increases its incidence.
HP11 Mutagenic: waste which may cause a mutation, that is a permanent change in the amount or structure of the genetic material in a cell.
649-191-00-8
A complex combination of hydrocarbons obtained from catalytic hydrodesulfurization of vacuum gas oil and from which hydrogen sulfide has been removed by amine treatment. It consists predominantly of hydrocarbons having carbon numbers predominantly in the range of C1 through C6.
269-632-4
68308-12-3
Flam. Gas 1
Carc. 1A
Muta. 1B
HP3 Flammable Waste (FW): (a)liq FW with flash pt <60°C or FW gas, diesel and light heating oils with flash pt >55°C and ≤75°C (b)pyrophoric liq/solid FW liable to ignite within 5 min after air contact (c)solid FW readily combustible or which may cause/contribute to fire by friction (d)gas FW which is F in air at 20°C and 101.3 kPa (e)water reactive FW which, in contact with water, emits F gases in dangerous quantities (f)other: aerosols, self-heating, organic peroxides and self-reactive FWs.
HP7 Carcinogenic: waste which induces cancer or increases its incidence.
HP11 Mutagenic: waste which may cause a mutation, that is a permanent change in the amount or structure of the genetic material in a cell.
649-190-00-2
A complex combination of hydrocarbons obtained from the distillation of the reaction products of propane with propylene. It consists of hydrocarbons having carbon numbers predominantly in the range of C1 through C4.
269-631-9
68308-11-2
Flam. Gas 1
Carc. 1A
Muta. 1B
HP3 Flammable Waste (FW): (a)liq FW with flash pt <60°C or FW gas, diesel and light heating oils with flash pt >55°C and ≤75°C (b)pyrophoric liq/solid FW liable to ignite within 5 min after air contact (c)solid FW readily combustible or which may cause/contribute to fire by friction (d)gas FW which is F in air at 20°C and 101.3 kPa (e)water reactive FW which, in contact with water, emits F gases in dangerous quantities (f)other: aerosols, self-heating, organic peroxides and self-reactive FWs.
HP7 Carcinogenic: waste which induces cancer or increases its incidence.
HP11 Mutagenic: waste which may cause a mutation, that is a permanent change in the amount or structure of the genetic material in a cell.
649-189-00-7
A complex combination of hydrocarbons obtained from fractionation stabilization of light straight run naphtha and from which hydrogen sulfide has been removed by amine treatment. It consists predominantly of hydrocarbons having carbon numbers predominantly in the range of C1 through C5.
269-629-8
68308-09-8
Flam. Gas 1
Carc. 1A
Muta. 1B
HP3 Flammable Waste (FW): (a)liq FW with flash pt <60°C or FW gas, diesel and light heating oils with flash pt >55°C and ≤75°C (b)pyrophoric liq/solid FW liable to ignite within 5 min after air contact (c)solid FW readily combustible or which may cause/contribute to fire by friction (d)gas FW which is F in air at 20°C and 101.3 kPa (e)water reactive FW which, in contact with water, emits F gases in dangerous quantities (f)other: aerosols, self-heating, organic peroxides and self-reactive FWs.
HP7 Carcinogenic: waste which induces cancer or increases its incidence.
HP11 Mutagenic: waste which may cause a mutation, that is a permanent change in the amount or structure of the genetic material in a cell.
649-188-00-1
A complex combination of hydrocarbons obtained from stripping stabilization of catalytic hydrodesulfurized vacuum gas oil and from which hydrogen sulfide has been removed by amine treatment. It consists predominantly of hydrocarbons having carbon numbers predominantly in the range of C1 through C6.
269-627-7
68308-07-6
Flam. Gas 1
Carc. 1A
Muta. 1B
HP3 Flammable Waste (FW): (a)liq FW with flash pt <60°C or FW gas, diesel and light heating oils with flash pt >55°C and ≤75°C (b)pyrophoric liq/solid FW liable to ignite within 5 min after air contact (c)solid FW readily combustible or which may cause/contribute to fire by friction (d)gas FW which is F in air at 20°C and 101.3 kPa (e)water reactive FW which, in contact with water, emits F gases in dangerous quantities (f)other: aerosols, self-heating, organic peroxides and self-reactive FWs.
HP7 Carcinogenic: waste which induces cancer or increases its incidence.
HP11 Mutagenic: waste which may cause a mutation, that is a permanent change in the amount or structure of the genetic material in a cell.
649-187-00-6
A complex combination of hydrocarbons obtained from fractionation of hydrodesulfurized naphtha and distillate hydrocarbon streams and treated to remove acidic impurities. It consists predominantly of hydrocarbons having carbon numbers predominantly in the range of C1 through C5.
269-626-1
68308-06-5
Flam. Gas 1
Carc. 1A
Muta. 1B
HP3 Flammable Waste (FW): (a)liq FW with flash pt <60°C or FW gas, diesel and light heating oils with flash pt >55°C and ≤75°C (b)pyrophoric liq/solid FW liable to ignite within 5 min after air contact (c)solid FW readily combustible or which may cause/contribute to fire by friction (d)gas FW which is F in air at 20°C and 101.3 kPa (e)water reactive FW which, in contact with water, emits F gases in dangerous quantities (f)other: aerosols, self-heating, organic peroxides and self-reactive FWs.
HP7 Carcinogenic: waste which induces cancer or increases its incidence.
HP11 Mutagenic: waste which may cause a mutation, that is a permanent change in the amount or structure of the genetic material in a cell.
649-186-00-0
A complex combination of hydrocarbons from the distillation of products from miscellaneous hydrocarbon streams. It consists of hydrocarbon having carbon numbers predominantly in the range of C1 through C4.
269-625-6
68308-05-4
Flam. Gas 1
Carc. 1A
Muta. 1B
HP3 Flammable Waste (FW): (a)liq FW with flash pt <60°C or FW gas, diesel and light heating oils with flash pt >55°C and ≤75°C (b)pyrophoric liq/solid FW liable to ignite within 5 min after air contact (c)solid FW readily combustible or which may cause/contribute to fire by friction (d)gas FW which is F in air at 20°C and 101.3 kPa (e)water reactive FW which, in contact with water, emits F gases in dangerous quantities (f)other: aerosols, self-heating, organic peroxides and self-reactive FWs.
HP7 Carcinogenic: waste which induces cancer or increases its incidence.
HP11 Mutagenic: waste which may cause a mutation, that is a permanent change in the amount or structure of the genetic material in a cell.
649-185-00-5
A complex combination of hydrocarbons from the distillation of products from miscellaneous hydrocarbon streams. It consists predominantly of hydrocarbons having carbon numbers predominantly in the range of C1 through C5.
269-624-0
68308-04-3
Flam. Gas 1
Carc. 1A
Muta. 1B
HP3 Flammable Waste (FW): (a)liq FW with flash pt <60°C or FW gas, diesel and light heating oils with flash pt >55°C and ≤75°C (b)pyrophoric liq/solid FW liable to ignite within 5 min after air contact (c)solid FW readily combustible or which may cause/contribute to fire by friction (d)gas FW which is F in air at 20°C and 101.3 kPa (e)water reactive FW which, in contact with water, emits F gases in dangerous quantities (f)other: aerosols, self-heating, organic peroxides and self-reactive FWs.
HP7 Carcinogenic: waste which induces cancer or increases its incidence.
HP11 Mutagenic: waste which may cause a mutation, that is a permanent change in the amount or structure of the genetic material in a cell.
649-184-00-X
A complex combination of hydrocarbons obtained from the distillation of products from the catalytic cracking of gas oil. It consists predominantly of hydrocarbons having carbon numbers predominantly in the range of C1 through C5.
269-623-5
68308-03-2
Flam. Gas 1
Carc. 1A
Muta. 1B
HP3 Flammable Waste (FW): (a)liq FW with flash pt <60°C or FW gas, diesel and light heating oils with flash pt >55°C and ≤75°C (b)pyrophoric liq/solid FW liable to ignite within 5 min after air contact (c)solid FW readily combustible or which may cause/contribute to fire by friction (d)gas FW which is F in air at 20°C and 101.3 kPa (e)water reactive FW which, in contact with water, emits F gases in dangerous quantities (f)other: aerosols, self-heating, organic peroxides and self-reactive FWs.
HP7 Carcinogenic: waste which induces cancer or increases its incidence.
HP11 Mutagenic: waste which may cause a mutation, that is a permanent change in the amount or structure of the genetic material in a cell.
649-183-00-4
A complex combination of hydrocarbons obtained from catalytic hydrodesulfurization of straight run distillates and from which hydrogen sulfide has been removed by amine treatment. It consists predominantly of hydrocarbons having carbon numbers predominantly in the range of C1 through C4.
269-630-3
68308-10-1
Flam. Gas 1
Carc. 1A
Muta. 1B
HP3 Flammable Waste (FW): (a)liq FW with flash pt <60°C or FW gas, diesel and light heating oils with flash pt >55°C and ≤75°C (b)pyrophoric liq/solid FW liable to ignite within 5 min after air contact (c)solid FW readily combustible or which may cause/contribute to fire by friction (d)gas FW which is F in air at 20°C and 101.3 kPa (e)water reactive FW which, in contact with water, emits F gases in dangerous quantities (f)other: aerosols, self-heating, organic peroxides and self-reactive FWs.
HP7 Carcinogenic: waste which induces cancer or increases its incidence.
HP11 Mutagenic: waste which may cause a mutation, that is a permanent change in the amount or structure of the genetic material in a cell.
649-182-00-9
A complex combination of hydrocarbons obtained by treating thermal cracked distillates with hydrogen in the presence of a catalyst. It consists predominantly of saturated hydrocarbons having carbon numbers predominantly in the range of C1 through C6.
269-620-9
68308-01-0
Flam. Gas 1
Carc. 1A
Muta. 1B
HP3 Flammable Waste (FW): (a)liq FW with flash pt <60°C or FW gas, diesel and light heating oils with flash pt >55°C and ≤75°C (b)pyrophoric liq/solid FW liable to ignite within 5 min after air contact (c)solid FW readily combustible or which may cause/contribute to fire by friction (d)gas FW which is F in air at 20°C and 101.3 kPa (e)water reactive FW which, in contact with water, emits F gases in dangerous quantities (f)other: aerosols, self-heating, organic peroxides and self-reactive FWs.
HP7 Carcinogenic: waste which induces cancer or increases its incidence.
HP11 Mutagenic: waste which may cause a mutation, that is a permanent change in the amount or structure of the genetic material in a cell.
649-181-00-3
A complex combination of hydrocarbons obtained from fractionation stabilization of catalytic reformed naphtha and from which hydrogen sulfide has been removed by amine treatment. It consists predominantly of hydrocarbons having carbon numbers predominantly in the range of C1 through C4.
269-619-3
68308-00-9
Flam. Gas 1
Carc. 1A
Muta. 1B
HP3 Flammable Waste (FW): (a)liq FW with flash pt <60°C or FW gas, diesel and light heating oils with flash pt >55°C and ≤75°C (b)pyrophoric liq/solid FW liable to ignite within 5 min after air contact (c)solid FW readily combustible or which may cause/contribute to fire by friction (d)gas FW which is F in air at 20°C and 101.3 kPa (e)water reactive FW which, in contact with water, emits F gases in dangerous quantities (f)other: aerosols, self-heating, organic peroxides and self-reactive FWs.
HP7 Carcinogenic: waste which induces cancer or increases its incidence.
HP11 Mutagenic: waste which may cause a mutation, that is a permanent change in the amount or structure of the genetic material in a cell.
649-180-00-8
A complex combination of hydrocarbons from the fractionation stabilization products from polymerization of naphtha. It consists predominantly of hydrocarbons having carbon numbers in the range of C1 through C4.
269-618-8
68307-99-3
Flam. Gas 1
Carc. 1A
Muta. 1B
HP3 Flammable Waste (FW): (a)liq FW with flash pt <60°C or FW gas, diesel and light heating oils with flash pt >55°C and ≤75°C (b)pyrophoric liq/solid FW liable to ignite within 5 min after air contact (c)solid FW readily combustible or which may cause/contribute to fire by friction (d)gas FW which is F in air at 20°C and 101.3 kPa (e)water reactive FW which, in contact with water, emits F gases in dangerous quantities (f)other: aerosols, self-heating, organic peroxides and self-reactive FWs.
HP7 Carcinogenic: waste which induces cancer or increases its incidence.
HP11 Mutagenic: waste which may cause a mutation, that is a permanent change in the amount or structure of the genetic material in a cell.
649-179-00-2
The complex combination of hydrocarbons from the distillation of the products from catalytic cracked distillates and catalytic cracked naphtha. It consists predominantly of hydrocarbons having carbon numbers in the range of C1 through C4.
269-617-2
68307-98-2
Flam. Gas 1
Carc. 1A
Muta. 1B
HP3 Flammable Waste (FW): (a)liq FW with flash pt <60°C or FW gas, diesel and light heating oils with flash pt >55°C and ≤75°C (b)pyrophoric liq/solid FW liable to ignite within 5 min after air contact (c)solid FW readily combustible or which may cause/contribute to fire by friction (d)gas FW which is F in air at 20°C and 101.3 kPa (e)water reactive FW which, in contact with water, emits F gases in dangerous quantities (f)other: aerosols, self-heating, organic peroxides and self-reactive FWs.
HP7 Carcinogenic: waste which induces cancer or increases its incidence.
HP11 Mutagenic: waste which may cause a mutation, that is a permanent change in the amount or structure of the genetic material in a cell.
649-178-00-7
A complex combination of hydrocarbons produced by distillation of products from the cracking of crude oil. It consists of hydrocarbons having carbon numbers in the range of C3 through C4, predominantly of propane and propylene, and boiling in the range of approximately -51°C to -1°C (-60°F to 30°F.)
268-629-5
68131-75-9
Flam. Gas 1
Carc. 1A
Muta. 1B
HP3 Flammable Waste (FW): (a)liq FW with flash pt <60°C or FW gas, diesel and light heating oils with flash pt >55°C and ≤75°C (b)pyrophoric liq/solid FW liable to ignite within 5 min after air contact (c)solid FW readily combustible or which may cause/contribute to fire by friction (d)gas FW which is F in air at 20°C and 101.3 kPa (e)water reactive FW which, in contact with water, emits F gases in dangerous quantities (f)other: aerosols, self-heating, organic peroxides and self-reactive FWs.
HP7 Carcinogenic: waste which induces cancer or increases its incidence.
HP11 Mutagenic: waste which may cause a mutation, that is a permanent change in the amount or structure of the genetic material in a cell.
649-177-00-1
A complex combination of hydrocarbons obtained by treatment of Foot's oil with natural or modified clay in either a contacting or percolation process to remove the trace amounts of polar compounds and impurities present. It consists predominantly of branched chain hydrocarbons with carbon numbers predominantly in the range of C20 through C50.
300-226-2
93924-32-4
Flam. Gas 1
Carc. 1B
HP3 Flammable Waste (FW): (a)liq FW with flash pt <60°C or FW gas, diesel and light heating oils with flash pt >55°C and ≤75°C (b)pyrophoric liq/solid FW liable to ignite within 5 min after air contact (c)solid FW readily combustible or which may cause/contribute to fire by friction (d)gas FW which is F in air at 20°C and 101.3 kPa (e)water reactive FW which, in contact with water, emits F gases in dangerous quantities (f)other: aerosols, self-heating, organic peroxides and self-reactive FWs.
HP7 Carcinogenic: waste which induces cancer or increases its incidence.
649-176-00-6
A complex combination of hydrocarbons obtained by treatment of Foot's oil with sulfuric acid. It consists predominantly of branched-chain hydrocarbons with carbon numbers predominantly in the range of C20 through C50.
300-225-7
93924-31-3
Flam. Gas 1
Carc. 1B
HP3 Flammable Waste (FW): (a)liq FW with flash pt <60°C or FW gas, diesel and light heating oils with flash pt >55°C and ≤75°C (b)pyrophoric liq/solid FW liable to ignite within 5 min after air contact (c)solid FW readily combustible or which may cause/contribute to fire by friction (d)gas FW which is F in air at 20°C and 101.3 kPa (e)water reactive FW which, in contact with water, emits F gases in dangerous quantities (f)other: aerosols, self-heating, organic peroxides and self-reactive FWs.
HP7 Carcinogenic: waste which induces cancer or increases its incidence.
649-175-00-0
A complex combination obtained from viscosity reduction of residues in a furnace. It consists predominantly of hydrogen sulfide and paraffinic and olefinic hydrocarbons having carbon numbers predominantly in the range of C1 through C5.
295-402-8
92045-20-0
Flam. Gas 1
Carc. 1A
Muta. 1B
HP3 Flammable Waste (FW): (a)liq FW with flash pt <60°C or FW gas, diesel and light heating oils with flash pt >55°C and ≤75°C (b)pyrophoric liq/solid FW liable to ignite within 5 min after air contact (c)solid FW readily combustible or which may cause/contribute to fire by friction (d)gas FW which is F in air at 20°C and 101.3 kPa (e)water reactive FW which, in contact with water, emits F gases in dangerous quantities (f)other: aerosols, self-heating, organic peroxides and self-reactive FWs.
HP7 Carcinogenic: waste which induces cancer or increases its incidence.
HP11 Mutagenic: waste which may cause a mutation, that is a permanent change in the amount or structure of the genetic material in a cell.
649-174-00-5
A complex combination obtained as a mixture of the non-condensable portions from the product of a naphtha steam cracking process as well as residual gases obtained during the preparation of subsequent products. It consists predominantly of hydrogen and paraffinic and olefinic hydrocarbons having carbon numbers predominantly in the range of C1 through C5 with which natural gas may also be mixed.
295-401-2
92045-19-7
Flam. Gas 1
Carc. 1A
Muta. 1B
HP3 Flammable Waste (FW): (a)liq FW with flash pt <60°C or FW gas, diesel and light heating oils with flash pt >55°C and ≤75°C (b)pyrophoric liq/solid FW liable to ignite within 5 min after air contact (c)solid FW readily combustible or which may cause/contribute to fire by friction (d)gas FW which is F in air at 20°C and 101.3 kPa (e)water reactive FW which, in contact with water, emits F gases in dangerous quantities (f)other: aerosols, self-heating, organic peroxides and self-reactive FWs.
HP7 Carcinogenic: waste which induces cancer or increases its incidence.
HP11 Mutagenic: waste which may cause a mutation, that is a permanent change in the amount or structure of the genetic material in a cell.
649-173-00-X
A complex combination of gases obtained from flash of the effluents after the hydrogenation reaction. It consists predominantly of hydrogen and aliphatic hydrocarbons having carbon numbers predominantly in the range of C1 through C6.
295-400-7
92045-18-6
Flam. Gas 1
Carc. 1A
Muta. 1B
HP3 Flammable Waste (FW): (a)liq FW with flash pt <60°C or FW gas, diesel and light heating oils with flash pt >55°C and ≤75°C (b)pyrophoric liq/solid FW liable to ignite within 5 min after air contact (c)solid FW readily combustible or which may cause/contribute to fire by friction (d)gas FW which is F in air at 20°C and 101.3 kPa (e)water reactive FW which, in contact with water, emits F gases in dangerous quantities (f)other: aerosols, self-heating, organic peroxides and self-reactive FWs.
HP7 Carcinogenic: waste which induces cancer or increases its incidence.
HP11 Mutagenic: waste which may cause a mutation, that is a permanent change in the amount or structure of the genetic material in a cell.
649-172-00-4
A complex combination of gases obtained from the reformer and from the purges from the hydrogenation reactor. It consists predominantly of hydrogen and aliphatic hydrocarbons having carbon numbers predominantly in the range of C1 through C4.
295-399-3
92045-17-5
Flam. Gas 1
Carc. 1A
Muta. 1B
HP3 Flammable Waste (FW): (a)liq FW with flash pt <60°C or FW gas, diesel and light heating oils with flash pt >55°C and ≤75°C (b)pyrophoric liq/solid FW liable to ignite within 5 min after air contact (c)solid FW readily combustible or which may cause/contribute to fire by friction (d)gas FW which is F in air at 20°C and 101.3 kPa (e)water reactive FW which, in contact with water, emits F gases in dangerous quantities (f)other: aerosols, self-heating, organic peroxides and self-reactive FWs.
HP7 Carcinogenic: waste which induces cancer or increases its incidence.
HP11 Mutagenic: waste which may cause a mutation, that is a permanent change in the amount or structure of the genetic material in a cell.
649-171-00-9
A complex combination obtained by separation of the liquid phase from the effluent from the hydrogenation reaction. It consists predominantly of hydrogen, hydrogen sulfide and aliphatic hydrocarbons having carbon numbers predominantly in the range of C1 through C3.
295-398-8
92045-16-4
Flam. Gas 1
Carc. 1A
Muta. 1B
HP3 Flammable Waste (FW): (a)liq FW with flash pt <60°C or FW gas, diesel and light heating oils with flash pt >55°C and ≤75°C (b)pyrophoric liq/solid FW liable to ignite within 5 min after air contact (c)solid FW readily combustible or which may cause/contribute to fire by friction (d)gas FW which is F in air at 20°C and 101.3 kPa (e)water reactive FW which, in contact with water, emits F gases in dangerous quantities (f)other: aerosols, self-heating, organic peroxides and self-reactive FWs.
HP7 Carcinogenic: waste which induces cancer or increases its incidence.
HP11 Mutagenic: waste which may cause a mutation, that is a permanent change in the amount or structure of the genetic material in a cell.
649-170-00-3
A complex combination produced by desulfurization of gas oils with diethanolamine. It consists predominantly of hydrogen sulfide, hydrogen and aliphatic hydrocarbons having carbon numbers in the range of C1 through C5.
295-397-2
92045-15-3
Flam. Gas 1
Carc. 1A
Muta. 1B
HP3 Flammable Waste (FW): (a)liq FW with flash pt <60°C or FW gas, diesel and light heating oils with flash pt >55°C and ≤75°C (b)pyrophoric liq/solid FW liable to ignite within 5 min after air contact (c)solid FW readily combustible or which may cause/contribute to fire by friction (d)gas FW which is F in air at 20°C and 101.3 kPa (e)water reactive FW which, in contact with water, emits F gases in dangerous quantities (f)other: aerosols, self-heating, organic peroxides and self-reactive FWs.
HP7 Carcinogenic: waste which induces cancer or increases its incidence.
HP11 Mutagenic: waste which may cause a mutation, that is a permanent change in the amount or structure of the genetic material in a cell.
649-169-00-8
A complex combination produced by crude distillation and catalytic cracking processes. It consists of hydrogen, hydrogen sulfide, nitrogen, carbon monoxide and paraffinic and olefinic hydrocarbons having carbon numbers predominantly in the range of C1 through C6.
273-563-5
68989-88-8
Flam. Gas 1
Carc. 1A
Muta. 1B
HP3 Flammable Waste (FW): (a)liq FW with flash pt <60°C or FW gas, diesel and light heating oils with flash pt >55°C and ≤75°C (b)pyrophoric liq/solid FW liable to ignite within 5 min after air contact (c)solid FW readily combustible or which may cause/contribute to fire by friction (d)gas FW which is F in air at 20°C and 101.3 kPa (e)water reactive FW which, in contact with water, emits F gases in dangerous quantities (f)other: aerosols, self-heating, organic peroxides and self-reactive FWs.
HP7 Carcinogenic: waste which induces cancer or increases its incidence.
HP11 Mutagenic: waste which may cause a mutation, that is a permanent change in the amount or structure of the genetic material in a cell.
649-168-00-2
A complex combination obtained by the fractionation of products from the fluidized catalytic cracker and gas oil desulfurizer. It consists of hydrogen and hydrocarbons having carbon numbers predominantly in the range of C1 through C4.
273-269-7
68955-33-9
Flam. Gas 1
Carc. 1A
Muta. 1B
HP3 Flammable Waste (FW): (a)liq FW with flash pt <60°C or FW gas, diesel and light heating oils with flash pt >55°C and ≤75°C (b)pyrophoric liq/solid FW liable to ignite within 5 min after air contact (c)solid FW readily combustible or which may cause/contribute to fire by friction (d)gas FW which is F in air at 20°C and 101.3 kPa (e)water reactive FW which, in contact with water, emits F gases in dangerous quantities (f)other: aerosols, self-heating, organic peroxides and self-reactive FWs.
HP7 Carcinogenic: waste which induces cancer or increases its incidence.
HP11 Mutagenic: waste which may cause a mutation, that is a permanent change in the amount or structure of the genetic material in a cell.
649-167-00-7
A complex combination obtained from the hydrodesulfurization of straight-run naphtha. It consists of hydrogen and hydrocarbons having carbon numbers predominantly in the range of C1 through C5.
273-174-0
68952-80-7
Flam. Gas 1
Carc. 1A
Muta. 1B
HP3 Flammable Waste (FW): (a)liq FW with flash pt <60°C or FW gas, diesel and light heating oils with flash pt >55°C and ≤75°C (b)pyrophoric liq/solid FW liable to ignite within 5 min after air contact (c)solid FW readily combustible or which may cause/contribute to fire by friction (d)gas FW which is F in air at 20°C and 101.3 kPa (e)water reactive FW which, in contact with water, emits F gases in dangerous quantities (f)other: aerosols, self-heating, organic peroxides and self-reactive FWs.
HP7 Carcinogenic: waste which induces cancer or increases its incidence.
HP11 Mutagenic: waste which may cause a mutation, that is a permanent change in the amount or structure of the genetic material in a cell.
649-166-00-1
A complex combination of hydrocarbons obtained from the hydrodesulfurization of naphtha. It consists of hydrogen, methane, ethane, and propane.
273-173-5
68952-79-4
Flam. Gas 1
Carc. 1A
Muta. 1B
HP3 Flammable Waste (FW): (a)liq FW with flash pt <60°C or FW gas, diesel and light heating oils with flash pt >55°C and ≤75°C (b)pyrophoric liq/solid FW liable to ignite within 5 min after air contact (c)solid FW readily combustible or which may cause/contribute to fire by friction (d)gas FW which is F in air at 20°C and 101.3 kPa (e)water reactive FW which, in contact with water, emits F gases in dangerous quantities (f)other: aerosols, self-heating, organic peroxides and self-reactive FWs.
HP7 Carcinogenic: waste which induces cancer or increases its incidence.
HP11 Mutagenic: waste which may cause a mutation, that is a permanent change in the amount or structure of the genetic material in a cell.
649-165-00-6
A combination of hydrogen and methane obtained by fractionation of the products from the unifiner unit.
272-885-3
68919-12-0
Flam. Gas 1
Carc. 1A
Muta. 1B
HP3 Flammable Waste (FW): (a)liq FW with flash pt <60°C or FW gas, diesel and light heating oils with flash pt >55°C and ≤75°C (b)pyrophoric liq/solid FW liable to ignite within 5 min after air contact (c)solid FW readily combustible or which may cause/contribute to fire by friction (d)gas FW which is F in air at 20°C and 101.3 kPa (e)water reactive FW which, in contact with water, emits F gases in dangerous quantities (f)other: aerosols, self-heating, organic peroxides and self-reactive FWs.
HP7 Carcinogenic: waste which induces cancer or increases its incidence.
HP11 Mutagenic: waste which may cause a mutation, that is a permanent change in the amount or structure of the genetic material in a cell.
649-164-00-0
A complex combination obtained by the fractionation of reduced crude oil. It consists of hydrogen and hydrocarbons having carbon numbers predominantly in the range of C1 through C4.
272-884-8
68919-11-9
Flam. Gas 1
Carc. 1A
Muta. 1B
HP3 Flammable Waste (FW): (a)liq FW with flash pt <60°C or FW gas, diesel and light heating oils with flash pt >55°C and ≤75°C (b)pyrophoric liq/solid FW liable to ignite within 5 min after air contact (c)solid FW readily combustible or which may cause/contribute to fire by friction (d)gas FW which is F in air at 20°C and 101.3 kPa (e)water reactive FW which, in contact with water, emits F gases in dangerous quantities (f)other: aerosols, self-heating, organic peroxides and self-reactive FWs.
HP7 Carcinogenic: waste which induces cancer or increases its incidence.
HP11 Mutagenic: waste which may cause a mutation, that is a permanent change in the amount or structure of the genetic material in a cell.
649-163-00-5
A complex combination produced from the first tower used in the distillation of crude oil. It consists of nitrogen and saturated aliphatic hydrocarbons having carbon numbers predominantly in the range of C1 through C5.
272-881-1
68919-08-4
Flam. Gas 1
Carc. 1A
Muta. 1B
HP3 Flammable Waste (FW): (a)liq FW with flash pt <60°C or FW gas, diesel and light heating oils with flash pt >55°C and ≤75°C (b)pyrophoric liq/solid FW liable to ignite within 5 min after air contact (c)solid FW readily combustible or which may cause/contribute to fire by friction (d)gas FW which is F in air at 20°C and 101.3 kPa (e)water reactive FW which, in contact with water, emits F gases in dangerous quantities (f)other: aerosols, self-heating, organic peroxides and self-reactive FWs.
HP7 Carcinogenic: waste which induces cancer or increases its incidence.
HP11 Mutagenic: waste which may cause a mutation, that is a permanent change in the amount or structure of the genetic material in a cell.
649-162-00-X
A complex combination obtained by the fractionation of the light ends of the platinum reactors of the platformer unit. It consists of hydrogen, methane, ethane, and propane.
272-880-6
68919-07-3
Flam. Gas 1
Carc. 1A
Muta. 1B
HP3 Flammable Waste (FW): (a)liq FW with flash pt <60°C or FW gas, diesel and light heating oils with flash pt >55°C and ≤75°C (b)pyrophoric liq/solid FW liable to ignite within 5 min after air contact (c)solid FW readily combustible or which may cause/contribute to fire by friction (d)gas FW which is F in air at 20°C and 101.3 kPa (e)water reactive FW which, in contact with water, emits F gases in dangerous quantities (f)other: aerosols, self-heating, organic peroxides and self-reactive FWs.
HP7 Carcinogenic: waste which induces cancer or increases its incidence.
HP11 Mutagenic: waste which may cause a mutation, that is a permanent change in the amount or structure of the genetic material in a cell.
649-161-00-4
A complex combination stripped from the liquid product of the heavy distillate hydrotreater desulfurization process. It consists of hydrogen, hydrogen sulfide, and saturated aliphatic hydrocarbons having carbon numbers predominantly in the range of C1 through C5.
272-876-4
68919-04-0
Flam. Gas 1
Carc. 1A
Muta. 1B
HP3 Flammable Waste (FW): (a)liq FW with flash pt <60°C or FW gas, diesel and light heating oils with flash pt >55°C and ≤75°C (b)pyrophoric liq/solid FW liable to ignite within 5 min after air contact (c)solid FW readily combustible or which may cause/contribute to fire by friction (d)gas FW which is F in air at 20°C and 101.3 kPa (e)water reactive FW which, in contact with water, emits F gases in dangerous quantities (f)other: aerosols, self-heating, organic peroxides and self-reactive FWs.
HP7 Carcinogenic: waste which induces cancer or increases its incidence.
HP11 Mutagenic: waste which may cause a mutation, that is a permanent change in the amount or structure of the genetic material in a cell.
649-160-00-9
A complex combination produced by scrubbing the overhead gas from the fluidized catalytic cracker. It consists of hydrogen, nitrogen, methane, ethane and propane.
272-875-9
68919-03-9
Flam. Gas 1
Carc. 1A
Muta. 1B
HP3 Flammable Waste (FW): (a)liq FW with flash pt <60°C or FW gas, diesel and light heating oils with flash pt >55°C and ≤75°C (b)pyrophoric liq/solid FW liable to ignite within 5 min after air contact (c)solid FW readily combustible or which may cause/contribute to fire by friction (d)gas FW which is F in air at 20°C and 101.3 kPa (e)water reactive FW which, in contact with water, emits F gases in dangerous quantities (f)other: aerosols, self-heating, organic peroxides and self-reactive FWs.
HP7 Carcinogenic: waste which induces cancer or increases its incidence.
HP11 Mutagenic: waste which may cause a mutation, that is a permanent change in the amount or structure of the genetic material in a cell.
649-159-00-3
A complex combination produced by the fractionation of the overhead product of the fluidized catalytic cracking process. It consists of hydrogen, hydrogen sulfide, nitrogen, and hydrocarbons having carbon numbers predominantly in the range of C1 through C5.
272-874-3
68919-02-8
Flam. Gas 1
Carc. 1A
Muta. 1B
HP3 Flammable Waste (FW): (a)liq FW with flash pt <60°C or FW gas, diesel and light heating oils with flash pt >55°C and ≤75°C (b)pyrophoric liq/solid FW liable to ignite within 5 min after air contact (c)solid FW readily combustible or which may cause/contribute to fire by friction (d)gas FW which is F in air at 20°C and 101.3 kPa (e)water reactive FW which, in contact with water, emits F gases in dangerous quantities (f)other: aerosols, self-heating, organic peroxides and self-reactive FWs.
HP7 Carcinogenic: waste which induces cancer or increases its incidence.
HP11 Mutagenic: waste which may cause a mutation, that is a permanent change in the amount or structure of the genetic material in a cell.
649-158-00-8
A complex combination stripped from the liquid product of the unifiner desulfurization process. It consists of hydrogen sulfide, methane, ethane, and propane.
272-873-8
68919-01-7
Flam. Gas 1
Carc. 1A
Muta. 1B
HP3 Flammable Waste (FW): (a)liq FW with flash pt <60°C or FW gas, diesel and light heating oils with flash pt >55°C and ≤75°C (b)pyrophoric liq/solid FW liable to ignite within 5 min after air contact (c)solid FW readily combustible or which may cause/contribute to fire by friction (d)gas FW which is F in air at 20°C and 101.3 kPa (e)water reactive FW which, in contact with water, emits F gases in dangerous quantities (f)other: aerosols, self-heating, organic peroxides and self-reactive FWs.
HP7 Carcinogenic: waste which induces cancer or increases its incidence.
HP11 Mutagenic: waste which may cause a mutation, that is a permanent change in the amount or structure of the genetic material in a cell.
649-157-00-2
A complex combination obtained from the flash drum of the unit treating sour kerosine with hydrogen in the presence of a catalyst. It consists primarily of hydrogen and methane with various small amounts of nitrogen, carbon monoxide, and hydrocarbons having carbon numbers predominantly in the range of C2 through C5.
272-776-0
68911-59-1
Flam. Gas 1
Carc. 1A
Muta. 1B
HP3 Flammable Waste (FW): (a)liq FW with flash pt <60°C or FW gas, diesel and light heating oils with flash pt >55°C and ≤75°C (b)pyrophoric liq/solid FW liable to ignite within 5 min after air contact (c)solid FW readily combustible or which may cause/contribute to fire by friction (d)gas FW which is F in air at 20°C and 101.3 kPa (e)water reactive FW which, in contact with water, emits F gases in dangerous quantities (f)other: aerosols, self-heating, organic peroxides and self-reactive FWs.
HP7 Carcinogenic: waste which induces cancer or increases its incidence.
HP11 Mutagenic: waste which may cause a mutation, that is a permanent change in the amount or structure of the genetic material in a cell.
649-156-00-7
The complex combination obtained from the depentanizer stabilization of hydrotreated kerosine. It consists primarily of hydrogen, methane, ethane, and propane with various small amounts of nitrogen, hydrogen sulfide, carbon monoxide and hydrocarbons having carbon numbers predominantly in the range of C4 through C5.
272-775-5
68911-58-0
Flam. Gas 1
Carc. 1A
Muta. 1B
HP3 Flammable Waste (FW): (a)liq FW with flash pt <60°C or FW gas, diesel and light heating oils with flash pt >55°C and ≤75°C (b)pyrophoric liq/solid FW liable to ignite within 5 min after air contact (c)solid FW readily combustible or which may cause/contribute to fire by friction (d)gas FW which is F in air at 20°C and 101.3 kPa (e)water reactive FW which, in contact with water, emits F gases in dangerous quantities (f)other: aerosols, self-heating, organic peroxides and self-reactive FWs.
HP7 Carcinogenic: waste which induces cancer or increases its incidence.
HP11 Mutagenic: waste which may cause a mutation, that is a permanent change in the amount or structure of the genetic material in a cell.
649-155-00-1
A complex combination obtained from the chemical reforming of naphthenes to aromatics. It consists of hydrogen and saturated aliphatic hydrocarbons having carbon numbers predominantly in the range of C2 through C4.
272-343-6
68814-90-4
Flam. Gas 1
Carc. 1A
Muta. 1B
HP3 Flammable Waste (FW): (a)liq FW with flash pt <60°C or FW gas, diesel and light heating oils with flash pt >55°C and ≤75°C (b)pyrophoric liq/solid FW liable to ignite within 5 min after air contact (c)solid FW readily combustible or which may cause/contribute to fire by friction (d)gas FW which is F in air at 20°C and 101.3 kPa (e)water reactive FW which, in contact with water, emits F gases in dangerous quantities (f)other: aerosols, self-heating, organic peroxides and self-reactive FWs.
HP7 Carcinogenic: waste which induces cancer or increases its incidence.
HP11 Mutagenic: waste which may cause a mutation, that is a permanent change in the amount or structure of the genetic material in a cell.
649-154-00-6
A complex combination obtained from various petroleum refining operations. It consists of hydrogen and hydrocarbons having carbon numbers predominantly in the range of C1 through C3.
272-338-9
68814-67-5
Flam. Gas 1
Carc. 1A
Muta. 1B
HP3 Flammable Waste (FW): (a)liq FW with flash pt <60°C or FW gas, diesel and light heating oils with flash pt >55°C and ≤75°C (b)pyrophoric liq/solid FW liable to ignite within 5 min after air contact (c)solid FW readily combustible or which may cause/contribute to fire by friction (d)gas FW which is F in air at 20°C and 101.3 kPa (e)water reactive FW which, in contact with water, emits F gases in dangerous quantities (f)other: aerosols, self-heating, organic peroxides and self-reactive FWs.
HP7 Carcinogenic: waste which induces cancer or increases its incidence.
HP11 Mutagenic: waste which may cause a mutation, that is a permanent change in the amount or structure of the genetic material in a cell.
649-153-00-0
A complex combination obtained by the liquid-vapor separation of the hydrocracking process reactor effluent. It consists predominantly of hydrogen and saturated hydrocarbons having carbon numbers predominantly in the range of C1 through C3.
272-182-1
68783-06-2
Flam. Gas 1
Carc. 1A
Muta. 1B
HP3 Flammable Waste (FW): (a)liq FW with flash pt <60°C or FW gas, diesel and light heating oils with flash pt >55°C and ≤75°C (b)pyrophoric liq/solid FW liable to ignite within 5 min after air contact (c)solid FW readily combustible or which may cause/contribute to fire by friction (d)gas FW which is F in air at 20°C and 101.3 kPa (e)water reactive FW which, in contact with water, emits F gases in dangerous quantities (f)other: aerosols, self-heating, organic peroxides and self-reactive FWs.
HP7 Carcinogenic: waste which induces cancer or increases its incidence.
HP11 Mutagenic: waste which may cause a mutation, that is a permanent change in the amount or structure of the genetic material in a cell.
649-152-00-5
A complex combination which consists primarily of hydrogen with various small amounts of methane, ethane, and propane.
271-750-6
68607-11-4
Flam. Gas 1
Carc. 1A
Muta. 1B
HP3 Flammable Waste (FW): (a)liq FW with flash pt <60°C or FW gas, diesel and light heating oils with flash pt >55°C and ≤75°C (b)pyrophoric liq/solid FW liable to ignite within 5 min after air contact (c)solid FW readily combustible or which may cause/contribute to fire by friction (d)gas FW which is F in air at 20°C and 101.3 kPa (e)water reactive FW which, in contact with water, emits F gases in dangerous quantities (f)other: aerosols, self-heating, organic peroxides and self-reactive FWs.
HP7 Carcinogenic: waste which induces cancer or increases its incidence.
HP11 Mutagenic: waste which may cause a mutation, that is a permanent change in the amount or structure of the genetic material in a cell.
649-151-00-X
A complex combination produced by the fractionation of the overhead products from the catalytic cracking process in the fluidized catalytic cracker. It consists of hydrogen, nitrogen, and hydrocarbons having carbon numbers predominantly in the range of C1 through C3.
271-625-6
68602-84-6
Flam. Gas 1
Carc. 1A
Muta. 1B
HP3 Flammable Waste (FW): (a)liq FW with flash pt <60°C or FW gas, diesel and light heating oils with flash pt >55°C and ≤75°C (b)pyrophoric liq/solid FW liable to ignite within 5 min after air contact (c)solid FW readily combustible or which may cause/contribute to fire by friction (d)gas FW which is F in air at 20°C and 101.3 kPa (e)water reactive FW which, in contact with water, emits F gases in dangerous quantities (f)other: aerosols, self-heating, organic peroxides and self-reactive FWs.
HP7 Carcinogenic: waste which induces cancer or increases its incidence.
HP11 Mutagenic: waste which may cause a mutation, that is a permanent change in the amount or structure of the genetic material in a cell.
649-150-00-4
A complex combination produced by treating the feed from the benzene unit with hydrogen in the presence of a catalyst followed by depentanizing. It consists primarily of hydrogen, ethane and propane with various small amounts of nitrogen, carbon monoxide, carbon dioxide and hydrocarbons having carbon numbers predominantly in the range of C1 through C6. It may contain trace amounts of benzene.
271-623-5
68602-82-4
Flam. Gas 1
Carc. 1A
Muta. 1B
HP3 Flammable Waste (FW): (a)liq FW with flash pt <60°C or FW gas, diesel and light heating oils with flash pt >55°C and ≤75°C (b)pyrophoric liq/solid FW liable to ignite within 5 min after air contact (c)solid FW readily combustible or which may cause/contribute to fire by friction (d)gas FW which is F in air at 20°C and 101.3 kPa (e)water reactive FW which, in contact with water, emits F gases in dangerous quantities (f)other: aerosols, self-heating, organic peroxides and self-reactive FWs.
HP7 Carcinogenic: waste which induces cancer or increases its incidence.
HP11 Mutagenic: waste which may cause a mutation, that is a permanent change in the amount or structure of the genetic material in a cell.
649-149-00-9
A complex combination separated by distillation of a gas stream containing hydrogen, carbon monoxide, carbon dioxide and hydrocarbons having carbon numbers in the range of C1 through C6 or obtained by cracking ethane and propane. It consists of hydrocarbons having carbon numbers predominantly in the range of C1 through C2, hydrogen, nitrogen, and carbon monoxide.
271-258-1
68527-15-1
Flam. Gas 1
Carc. 1A
Muta. 1B
HP3 Flammable Waste (FW): (a)liq FW with flash pt <60°C or FW gas, diesel and light heating oils with flash pt >55°C and ≤75°C (b)pyrophoric liq/solid FW liable to ignite within 5 min after air contact (c)solid FW readily combustible or which may cause/contribute to fire by friction (d)gas FW which is F in air at 20°C and 101.3 kPa (e)water reactive FW which, in contact with water, emits F gases in dangerous quantities (f)other: aerosols, self-heating, organic peroxides and self-reactive FWs.
HP7 Carcinogenic: waste which induces cancer or increases its incidence.
HP11 Mutagenic: waste which may cause a mutation, that is a permanent change in the amount or structure of the genetic material in a cell.
649-148-00-3
A complex combination produced by low-pressure flashing of the effluent from the reforming reactor. It consists primarily of hydrogen with various small amounts of methane, ethane, and propane.
271-005-5
68513-19-9
Flam. Gas 1
Carc. 1A
Muta. 1B
HP3 Flammable Waste (FW): (a)liq FW with flash pt <60°C or FW gas, diesel and light heating oils with flash pt >55°C and ≤75°C (b)pyrophoric liq/solid FW liable to ignite within 5 min after air contact (c)solid FW readily combustible or which may cause/contribute to fire by friction (d)gas FW which is F in air at 20°C and 101.3 kPa (e)water reactive FW which, in contact with water, emits F gases in dangerous quantities (f)other: aerosols, self-heating, organic peroxides and self-reactive FWs.
HP7 Carcinogenic: waste which induces cancer or increases its incidence.
HP11 Mutagenic: waste which may cause a mutation, that is a permanent change in the amount or structure of the genetic material in a cell.
649-147-00-8
A complex combination produced by the high-pressure flashing of the effluent from the reforming reactor. It consists primarily of hydrogen with various small amounts of methane, ethane, and propane.
271-003-4
68513-18-8
Flam. Gas 1
Carc. 1A
Muta. 1B
HP3 Flammable Waste (FW): (a)liq FW with flash pt <60°C or FW gas, diesel and light heating oils with flash pt >55°C and ≤75°C (b)pyrophoric liq/solid FW liable to ignite within 5 min after air contact (c)solid FW readily combustible or which may cause/contribute to fire by friction (d)gas FW which is F in air at 20°C and 101.3 kPa (e)water reactive FW which, in contact with water, emits F gases in dangerous quantities (f)other: aerosols, self-heating, organic peroxides and self-reactive FWs.
HP7 Carcinogenic: waste which induces cancer or increases its incidence.
HP11 Mutagenic: waste which may cause a mutation, that is a permanent change in the amount or structure of the genetic material in a cell.
649-146-00-2
A complex combination of hydrocarbons obtained from the catalytic reforming of straight-run naphtha followed by fractionation of the total effluent. It consists of hydrogen, methane, ethane and propane.
270-999-8
68513-14-4
Flam. Gas 1
Carc. 1A
Muta. 1B
HP3 Flammable Waste (FW): (a)liq FW with flash pt <60°C or FW gas, diesel and light heating oils with flash pt >55°C and ≤75°C (b)pyrophoric liq/solid FW liable to ignite within 5 min after air contact (c)solid FW readily combustible or which may cause/contribute to fire by friction (d)gas FW which is F in air at 20°C and 101.3 kPa (e)water reactive FW which, in contact with water, emits F gases in dangerous quantities (f)other: aerosols, self-heating, organic peroxides and self-reactive FWs.
HP7 Carcinogenic: waste which induces cancer or increases its incidence.
HP11 Mutagenic: waste which may cause a mutation, that is a permanent change in the amount or structure of the genetic material in a cell.
649-145-00-7
A complex combination of hydrocarbons obtained from hydrodesulfurization of straight-run naphtha. It consists of hydrogen and saturated aliphatic hydrocarbons having carbon numbers predominantly in the range of C1 through C6.
270-810-9
68478-30-8
Flam. Gas 1
Carc. 1A
Muta. 1B
HP3 Flammable Waste (FW): (a)liq FW with flash pt <60°C or FW gas, diesel and light heating oils with flash pt >55°C and ≤75°C (b)pyrophoric liq/solid FW liable to ignite within 5 min after air contact (c)solid FW readily combustible or which may cause/contribute to fire by friction (d)gas FW which is F in air at 20°C and 101.3 kPa (e)water reactive FW which, in contact with water, emits F gases in dangerous quantities (f)other: aerosols, self-heating, organic peroxides and self-reactive FWs.
HP7 Carcinogenic: waste which induces cancer or increases its incidence.
HP11 Mutagenic: waste which may cause a mutation, that is a permanent change in the amount or structure of the genetic material in a cell.
649-144-00-1
A complex combination of hydrocarbons obtained by treating cracked distillates with hydrogen in the presence of a catalyst. It consists of hydrogen and saturated aliphatic hydrocarbons having carbon numbers predominantly in the range of C1 through C5.
270-809-3
68478-29-5
Flam. Gas 1
Carc. 1A
Muta. 1B
HP3 Flammable Waste (FW): (a)liq FW with flash pt <60°C or FW gas, diesel and light heating oils with flash pt >55°C and ≤75°C (b)pyrophoric liq/solid FW liable to ignite within 5 min after air contact (c)solid FW readily combustible or which may cause/contribute to fire by friction (d)gas FW which is F in air at 20°C and 101.3 kPa (e)water reactive FW which, in contact with water, emits F gases in dangerous quantities (f)other: aerosols, self-heating, organic peroxides and self-reactive FWs.
HP7 Carcinogenic: waste which induces cancer or increases its incidence.
HP11 Mutagenic: waste which may cause a mutation, that is a permanent change in the amount or structure of the genetic material in a cell.
649-143-00-6
A complex combination of hydrocarbons obtained from the stabilization of catalytic reformed naphtha. It consists of hydrogen and hydrocarbons having carbon numbers predominantly in the range of C1 through C6.
270-808-8
68478-28-4
Flam. Gas 1
Carc. 1A
Muta. 1B
HP3 Flammable Waste (FW): (a)liq FW with flash pt <60°C or FW gas, diesel and light heating oils with flash pt >55°C and ≤75°C (b)pyrophoric liq/solid FW liable to ignite within 5 min after air contact (c)solid FW readily combustible or which may cause/contribute to fire by friction (d)gas FW which is F in air at 20°C and 101.3 kPa (e)water reactive FW which, in contact with water, emits F gases in dangerous quantities (f)other: aerosols, self-heating, organic peroxides and self-reactive FWs.
HP7 Carcinogenic: waste which induces cancer or increases its incidence.
HP11 Mutagenic: waste which may cause a mutation, that is a permanent change in the amount or structure of the genetic material in a cell.
649-142-00-0
A complex combination of hydrocarbons obtained from the catalytic reforming of straight run naphtha. It consists of hydrogen and hydrocarbons having carbon numbers predominantly in the range of C1 through C6.
270-807-2
68478-27-3
Flam. Gas 1
Carc. 1A
Muta. 1B
HP3 Flammable Waste (FW): (a)liq FW with flash pt <60°C or FW gas, diesel and light heating oils with flash pt >55°C and ≤75°C (b)pyrophoric liq/solid FW liable to ignite within 5 min after air contact (c)solid FW readily combustible or which may cause/contribute to fire by friction (d)gas FW which is F in air at 20°C and 101.3 kPa (e)water reactive FW which, in contact with water, emits F gases in dangerous quantities (f)other: aerosols, self-heating, organic peroxides and self-reactive FWs.
HP7 Carcinogenic: waste which induces cancer or increases its incidence.
HP11 Mutagenic: waste which may cause a mutation, that is a permanent change in the amount or structure of the genetic material in a cell.
649-141-00-5
A complex combination of hydrocarbons obtained from refractionation of products from a catalytic cracking process. It consists of hydrogen and hydrocarbons having carbon numbers predominantly in the range of C1 through C3.
270-805-1
68478-25-1
Flam. Gas 1
Carc. 1A
Muta. 1B
HP3 Flammable Waste (FW): (a)liq FW with flash pt <60°C or FW gas, diesel and light heating oils with flash pt >55°C and ≤75°C (b)pyrophoric liq/solid FW liable to ignite within 5 min after air contact (c)solid FW readily combustible or which may cause/contribute to fire by friction (d)gas FW which is F in air at 20°C and 101.3 kPa (e)water reactive FW which, in contact with water, emits F gases in dangerous quantities (f)other: aerosols, self-heating, organic peroxides and self-reactive FWs.
HP7 Carcinogenic: waste which induces cancer or increases its incidence.
HP11 Mutagenic: waste which may cause a mutation, that is a permanent change in the amount or structure of the genetic material in a cell.
649-140-00-X
A complex combination produced by distillation of products from a thermal cracking process. It consists of hydrogen, hydrogen sulfide, carbon monoxide, carbon dioxide and hydrocarbons having carbon numbers predominantly in the range of C1 through C6.
270-789-6
68478-05-7
Flam. Gas 1
Carc. 1A
Muta. 1B
HP3 Flammable Waste (FW): (a)liq FW with flash pt <60°C or FW gas, diesel and light heating oils with flash pt >55°C and ≤75°C (b)pyrophoric liq/solid FW liable to ignite within 5 min after air contact (c)solid FW readily combustible or which may cause/contribute to fire by friction (d)gas FW which is F in air at 20°C and 101.3 kPa (e)water reactive FW which, in contact with water, emits F gases in dangerous quantities (f)other: aerosols, self-heating, organic peroxides and self-reactive FWs.
HP7 Carcinogenic: waste which induces cancer or increases its incidence.
HP11 Mutagenic: waste which may cause a mutation, that is a permanent change in the amount or structure of the genetic material in a cell.
649-139-00-4
A complex combination obtained from the reforming hydrotreating process. It consists primarily of hydrogen with various small amounts of carbon monoxide and aliphatic hydrocarbons having carbon numbers predominantly in the range of C1 through C5.
270-788-0
68478-04-6
Flam. Gas 1
Carc. 1A
Muta. 1B
HP3 Flammable Waste (FW): (a)liq FW with flash pt <60°C or FW gas, diesel and light heating oils with flash pt >55°C and ≤75°C (b)pyrophoric liq/solid FW liable to ignite within 5 min after air contact (c)solid FW readily combustible or which may cause/contribute to fire by friction (d)gas FW which is F in air at 20°C and 101.3 kPa (e)water reactive FW which, in contact with water, emits F gases in dangerous quantities (f)other: aerosols, self-heating, organic peroxides and self-reactive FWs.
HP7 Carcinogenic: waste which induces cancer or increases its incidence.
HP11 Mutagenic: waste which may cause a mutation, that is a permanent change in the amount or structure of the genetic material in a cell.
649-138-00-9
A complex combination obtained from the reforming hydrotreating process. It consists primarily of hydrogen and methane with various small amounts of carbon monoxide, carbon dioxide, nitrogen and saturated aliphatic hydrocarbons having carbon numbers predominantly in the range of C2 through C5.
270-787-5
68478-03-5
Flam. Gas 1
Carc. 1A
Muta. 1B
HP3 Flammable Waste (FW): (a)liq FW with flash pt <60°C or FW gas, diesel and light heating oils with flash pt >55°C and ≤75°C (b)pyrophoric liq/solid FW liable to ignite within 5 min after air contact (c)solid FW readily combustible or which may cause/contribute to fire by friction (d)gas FW which is F in air at 20°C and 101.3 kPa (e)water reactive FW which, in contact with water, emits F gases in dangerous quantities (f)other: aerosols, self-heating, organic peroxides and self-reactive FWs.
HP7 Carcinogenic: waste which induces cancer or increases its incidence.
HP11 Mutagenic: waste which may cause a mutation, that is a permanent change in the amount or structure of the genetic material in a cell.
649-137-00-3
A complex combination obtained from the reforming hydrotreating process. It consists primarily of hydrogen, methane, and ethane with various small amounts of hydrogen sulfide and aliphatic hydrocarbons having carbon numbers predominantly in the range of C3 through C5.
270-785-4
68478-02-4
Flam. Gas 1
Carc. 1A
Muta. 1B
HP3 Flammable Waste (FW): (a)liq FW with flash pt <60°C or FW gas, diesel and light heating oils with flash pt >55°C and ≤75°C (b)pyrophoric liq/solid FW liable to ignite within 5 min after air contact (c)solid FW readily combustible or which may cause/contribute to fire by friction (d)gas FW which is F in air at 20°C and 101.3 kPa (e)water reactive FW which, in contact with water, emits F gases in dangerous quantities (f)other: aerosols, self-heating, organic peroxides and self-reactive FWs.
HP7 Carcinogenic: waste which induces cancer or increases its incidence.
HP11 Mutagenic: waste which may cause a mutation, that is a permanent change in the amount or structure of the genetic material in a cell.
649-136-00-8
A complex combination obtained from the reformers. It consists primarily of hydrogen with various small amounts of carbon monoxide and aliphatic hydrocarbons having carbon numbers predominantly in the range of C1 through C5.
270-784-9
68478-01-3
Flam. Gas 1
Carc. 1A
Muta. 1B
HP3 Flammable Waste (FW): (a)liq FW with flash pt <60°C or FW gas, diesel and light heating oils with flash pt >55°C and ≤75°C (b)pyrophoric liq/solid FW liable to ignite within 5 min after air contact (c)solid FW readily combustible or which may cause/contribute to fire by friction (d)gas FW which is F in air at 20°C and 101.3 kPa (e)water reactive FW which, in contact with water, emits F gases in dangerous quantities (f)other: aerosols, self-heating, organic peroxides and self-reactive FWs.
HP7 Carcinogenic: waste which induces cancer or increases its incidence.
HP11 Mutagenic: waste which may cause a mutation, that is a permanent change in the amount or structure of the genetic material in a cell.
649-135-00-2
A complex combination obtained from recycled reactor gases. It consists primarily of hydrogen with various small amounts of carbon monoxide, carbon dioxide, nitrogen, hydrogen sulfide, and saturated aliphatic hydrocarbons having carbon numbers in the range of C1 through C5.
270-783-3
68478-00-2
Flam. Gas 1
Carc. 1A
Muta. 1B
HP3 Flammable Waste (FW): (a)liq FW with flash pt <60°C or FW gas, diesel and light heating oils with flash pt >55°C and ≤75°C (b)pyrophoric liq/solid FW liable to ignite within 5 min after air contact (c)solid FW readily combustible or which may cause/contribute to fire by friction (d)gas FW which is F in air at 20°C and 101.3 kPa (e)water reactive FW which, in contact with water, emits F gases in dangerous quantities (f)other: aerosols, self-heating, organic peroxides and self-reactive FWs.
HP7 Carcinogenic: waste which induces cancer or increases its incidence.
HP11 Mutagenic: waste which may cause a mutation, that is a permanent change in the amount or structure of the genetic material in a cell.
649-134-00-7
A complex combination obtained from recycled hydrotreated blend oil. It consists primarily of hydrogen and nitrogen with various small amounts of carbon monoxide, carbon dioxide and hydrocarbons having carbon numbers predominantly in the range of C1 through C5.
270-781-2
68477-98-5
Flam. Gas 1
Carc. 1A
Muta. 1B
HP3 Flammable Waste (FW): (a)liq FW with flash pt <60°C or FW gas, diesel and light heating oils with flash pt >55°C and ≤75°C (b)pyrophoric liq/solid FW liable to ignite within 5 min after air contact (c)solid FW readily combustible or which may cause/contribute to fire by friction (d)gas FW which is F in air at 20°C and 101.3 kPa (e)water reactive FW which, in contact with water, emits F gases in dangerous quantities (f)other: aerosols, self-heating, organic peroxides and self-reactive FWs.
HP7 Carcinogenic: waste which induces cancer or increases its incidence.
HP11 Mutagenic: waste which may cause a mutation, that is a permanent change in the amount or structure of the genetic material in a cell.
649-133-00-1
A complex combination separated as a gas from hydrocarbon gases by chilling. It consists primarily of hydrogen with various small amounts of carbon monoxide, nitrogen, methane, and C2 hydrocarbons.
270-780-7
68477-97-4
Flam. Gas 1
Carc. 1A
Muta. 1B
HP3 Flammable Waste (FW): (a)liq FW with flash pt <60°C or FW gas, diesel and light heating oils with flash pt >55°C and ≤75°C (b)pyrophoric liq/solid FW liable to ignite within 5 min after air contact (c)solid FW readily combustible or which may cause/contribute to fire by friction (d)gas FW which is F in air at 20°C and 101.3 kPa (e)water reactive FW which, in contact with water, emits F gases in dangerous quantities (f)other: aerosols, self-heating, organic peroxides and self-reactive FWs.
HP7 Carcinogenic: waste which induces cancer or increases its incidence.
HP11 Mutagenic: waste which may cause a mutation, that is a permanent change in the amount or structure of the genetic material in a cell.
649-132-00-6
A complex combination obtained by absorbing hydrogen from a hydrogen rich stream. It consists of hydrogen, carbon monoxide, nitrogen, and methane with small amounts of C2 hydrocarbons.
270-779-1
68477-96-3
Flam. Gas 1
Carc. 1A
Muta. 1B
HP3 Flammable Waste (FW): (a)liq FW with flash pt <60°C or FW gas, diesel and light heating oils with flash pt >55°C and ≤75°C (b)pyrophoric liq/solid FW liable to ignite within 5 min after air contact (c)solid FW readily combustible or which may cause/contribute to fire by friction (d)gas FW which is F in air at 20°C and 101.3 kPa (e)water reactive FW which, in contact with water, emits F gases in dangerous quantities (f)other: aerosols, self-heating, organic peroxides and self-reactive FWs.
HP7 Carcinogenic: waste which induces cancer or increases its incidence.
HP11 Mutagenic: waste which may cause a mutation, that is a permanent change in the amount or structure of the genetic material in a cell.
649-131-00-0
A complex combination of hydrocarbons produced by distillation of products from combined gas streams in a gas concentration reabsorber. It consists predominantly of hydrogen, carbon monoxide, carbon dioxide, nitrogen, hydrogen sulfide and hydrocarbons having carbon numbers in the range of C1 through C3.
270-776-5
68477-93-0
Flam. Gas 1
Carc. 1A
Muta. 1B
HP3 Flammable Waste (FW): (a)liq FW with flash pt <60°C or FW gas, diesel and light heating oils with flash pt >55°C and ≤75°C (b)pyrophoric liq/solid FW liable to ignite within 5 min after air contact (c)solid FW readily combustible or which may cause/contribute to fire by friction (d)gas FW which is F in air at 20°C and 101.3 kPa (e)water reactive FW which, in contact with water, emits F gases in dangerous quantities (f)other: aerosols, self-heating, organic peroxides and self-reactive FWs.
HP7 Carcinogenic: waste which induces cancer or increases its incidence.
HP11 Mutagenic: waste which may cause a mutation, that is a permanent change in the amount or structure of the genetic material in a cell.
649-130-00-5
The complex combination of dry gases from a gas concentration unit. It consists of hydrogen, hydrogen sulfide and hydrocarbons having carbon numbers predominantly in the range of C1 through C3.
270-774-4
68477-92-9
Flam. Gas 1
Carc. 1A
Muta. 1B
HP3 Flammable Waste (FW): (a)liq FW with flash pt <60°C or FW gas, diesel and light heating oils with flash pt >55°C and ≤75°C (b)pyrophoric liq/solid FW liable to ignite within 5 min after air contact (c)solid FW readily combustible or which may cause/contribute to fire by friction (d)gas FW which is F in air at 20°C and 101.3 kPa (e)water reactive FW which, in contact with water, emits F gases in dangerous quantities (f)other: aerosols, self-heating, organic peroxides and self-reactive FWs.
HP7 Carcinogenic: waste which induces cancer or increases its incidence.
HP11 Mutagenic: waste which may cause a mutation, that is a permanent change in the amount or structure of the genetic material in a cell.
649-129-00-X
A complex combination of hydrocarbons obtained by the extraction of hydrogen from a gas stream which consists primarily of hydrogen with small amounts of nitrogen, carbon monoxide, methane, ethane, and ethylene. It contains predominantly hydrocarbons such as methane, ethane, and ethylene with small amounts of hydrogen, nitrogen and carbon monoxide.
270-766-0
68477-84-9
Flam. Gas 1
Carc. 1A
Muta. 1B
HP3 Flammable Waste (FW): (a)liq FW with flash pt <60°C or FW gas, diesel and light heating oils with flash pt >55°C and ≤75°C (b)pyrophoric liq/solid FW liable to ignite within 5 min after air contact (c)solid FW readily combustible or which may cause/contribute to fire by friction (d)gas FW which is F in air at 20°C and 101.3 kPa (e)water reactive FW which, in contact with water, emits F gases in dangerous quantities (f)other: aerosols, self-heating, organic peroxides and self-reactive FWs.
HP7 Carcinogenic: waste which induces cancer or increases its incidence.
HP11 Mutagenic: waste which may cause a mutation, that is a permanent change in the amount or structure of the genetic material in a cell.
649-128-00-4
270-763-4
68477-82-7
Flam. Gas 1
Carc. 1A
Muta. 1B
HP3 Flammable Waste (FW): (a)liq FW with flash pt <60°C or FW gas, diesel and light heating oils with flash pt >55°C and ≤75°C (b)pyrophoric liq/solid FW liable to ignite within 5 min after air contact (c)solid FW readily combustible or which may cause/contribute to fire by friction (d)gas FW which is F in air at 20°C and 101.3 kPa (e)water reactive FW which, in contact with water, emits F gases in dangerous quantities (f)other: aerosols, self-heating, organic peroxides and self-reactive FWs.
HP7 Carcinogenic: waste which induces cancer or increases its incidence.
HP11 Mutagenic: waste which may cause a mutation, that is a permanent change in the amount or structure of the genetic material in a cell.
649-127-00-9
A complex combination of hydrocarbons produced by distillation of products from catalytic reforming of C6-C8 feed. It consists of hydrocarbons having carbon numbers in the range of C1 through C5 and hydrogen.
270-762-9
68477-81-6
Flam. Gas 1
Carc. 1A
Muta. 1B
HP3 Flammable Waste (FW): (a)liq FW with flash pt <60°C or FW gas, diesel and light heating oils with flash pt >55°C and ≤75°C (b)pyrophoric liq/solid FW liable to ignite within 5 min after air contact (c)solid FW readily combustible or which may cause/contribute to fire by friction (d)gas FW which is F in air at 20°C and 101.3 kPa (e)water reactive FW which, in contact with water, emits F gases in dangerous quantities (f)other: aerosols, self-heating, organic peroxides and self-reactive FWs.
HP7 Carcinogenic: waste which induces cancer or increases its incidence.
HP11 Mutagenic: waste which may cause a mutation, that is a permanent change in the amount or structure of the genetic material in a cell.
649-126-00-3
A complex combination of hydrocarbons produced by distillation of products from catalytic reforming of C6-C8 feed and recycled to conserve hydrogen. It consists primarily of hydrogen. It may also contain various small amounts of carbon monoxide, carbon dioxide, nitrogen, and hydrocarbons having carbon numbers predominantly in the range of C1 through C6.
270-761-3
68477-80-5
Flam. Gas 1
Carc. 1A
Muta. 1B
HP3 Flammable Waste (FW): (a)liq FW with flash pt <60°C or FW gas, diesel and light heating oils with flash pt >55°C and ≤75°C (b)pyrophoric liq/solid FW liable to ignite within 5 min after air contact (c)solid FW readily combustible or which may cause/contribute to fire by friction (d)gas FW which is F in air at 20°C and 101.3 kPa (e)water reactive FW which, in contact with water, emits F gases in dangerous quantities (f)other: aerosols, self-heating, organic peroxides and self-reactive FWs.
HP7 Carcinogenic: waste which induces cancer or increases its incidence.
HP11 Mutagenic: waste which may cause a mutation, that is a permanent change in the amount or structure of the genetic material in a cell.
649-125-00-8
A complex combination of hydrocarbons obtained from the stabilization of catalytic reformed naphtha. Its consists of hydrogen and saturated aliphatic hydrocarbons having carbon numbers predominantly in the range of C1 through C4.
270-759-2
68477-77-0
Flam. Gas 1
Carc. 1A
Muta. 1B
HP3 Flammable Waste (FW): (a)liq FW with flash pt <60°C or FW gas, diesel and light heating oils with flash pt >55°C and ≤75°C (b)pyrophoric liq/solid FW liable to ignite within 5 min after air contact (c)solid FW readily combustible or which may cause/contribute to fire by friction (d)gas FW which is F in air at 20°C and 101.3 kPa (e)water reactive FW which, in contact with water, emits F gases in dangerous quantities (f)other: aerosols, self-heating, organic peroxides and self-reactive FWs.
HP7 Carcinogenic: waste which induces cancer or increases its incidence.
HP11 Mutagenic: waste which may cause a mutation, that is a permanent change in the amount or structure of the genetic material in a cell.
649-124-00-2
A complex combination of hydrocarbons obtained by distillation of a blend oil. It consists primarily of hydrogen and nitrogen with various small amounts of carbon monoxide, carbon dioxide, and aliphatic hydrocarbons having carbon numbers predominantly in the range of C1 through C5.
270-749-8
68477-68-9
Flam. Gas 1
Carc. 1A
Muta. 1B
HP3 Flammable Waste (FW): (a)liq FW with flash pt <60°C or FW gas, diesel and light heating oils with flash pt >55°C and ≤75°C (b)pyrophoric liq/solid FW liable to ignite within 5 min after air contact (c)solid FW readily combustible or which may cause/contribute to fire by friction (d)gas FW which is F in air at 20°C and 101.3 kPa (e)water reactive FW which, in contact with water, emits F gases in dangerous quantities (f)other: aerosols, self-heating, organic peroxides and self-reactive FWs.
HP7 Carcinogenic: waste which induces cancer or increases its incidence.
HP11 Mutagenic: waste which may cause a mutation, that is a permanent change in the amount or structure of the genetic material in a cell.
649-123-00-7
A complex combination of hydrocarbons obtained by recycling the gases of the benzene unit. It consists primarily of hydrogen with various small amounts of carbon monoxide and hydrocarbons having carbon numbers in the range of C1 through C6.
270-748-2
68477-67-8
Flam. Gas 1
Carc. 1A
Muta. 1B
HP3 Flammable Waste (FW): (a)liq FW with flash pt <60°C or FW gas, diesel and light heating oils with flash pt >55°C and ≤75°C (b)pyrophoric liq/solid FW liable to ignite within 5 min after air contact (c)solid FW readily combustible or which may cause/contribute to fire by friction (d)gas FW which is F in air at 20°C and 101.3 kPa (e)water reactive FW which, in contact with water, emits F gases in dangerous quantities (f)other: aerosols, self-heating, organic peroxides and self-reactive FWs.
HP7 Carcinogenic: waste which induces cancer or increases its incidence.
HP11 Mutagenic: waste which may cause a mutation, that is a permanent change in the amount or structure of the genetic material in a cell.
649-122-00-1
Off gases produced by the benzene unit. It consists primarily of hydrogen. Carbon monoxide and hydrocarbons having carbon numbers predominantly in the range of C1 through C6, including benzene, may also be present.
270-747-7
68477-66-7
Flam. Gas 1
Carc. 1A
Muta. 1B
HP3 Flammable Waste (FW): (a)liq FW with flash pt <60°C or FW gas, diesel and light heating oils with flash pt >55°C and ≤75°C (b)pyrophoric liq/solid FW liable to ignite within 5 min after air contact (c)solid FW readily combustible or which may cause/contribute to fire by friction (d)gas FW which is F in air at 20°C and 101.3 kPa (e)water reactive FW which, in contact with water, emits F gases in dangerous quantities (f)other: aerosols, self-heating, organic peroxides and self-reactive FWs.
HP7 Carcinogenic: waste which induces cancer or increases its incidence.
HP11 Mutagenic: waste which may cause a mutation, that is a permanent change in the amount or structure of the genetic material in a cell.
649-121-00-6
The feed gas to the amine system for removal of hydrogen sulfide. It consists of hydrogen. Carbon monoxide, carbon dioxide, hydrogen sulfide and aliphatic hydrocarbons having carbon numbers predominantly in the range of C1 through C5 may also be present.
270-746-1
68477-65-6
Flam. Gas 1
Carc. 1A
Muta. 1B
HP3 Flammable Waste (FW): (a)liq FW with flash pt <60°C or FW gas, diesel and light heating oils with flash pt >55°C and ≤75°C (b)pyrophoric liq/solid FW liable to ignite within 5 min after air contact (c)solid FW readily combustible or which may cause/contribute to fire by friction (d)gas FW which is F in air at 20°C and 101.3 kPa (e)water reactive FW which, in contact with water, emits F gases in dangerous quantities (f)other: aerosols, self-heating, organic peroxides and self-reactive FWs.
HP7 Carcinogenic: waste which induces cancer or increases its incidence.
HP11 Mutagenic: waste which may cause a mutation, that is a permanent change in the amount or structure of the genetic material in a cell.
649-120-00-0
307-769-4
97722-19-5
Flam. Gas 1
Carc. 1A
Muta. 1B
HP3 Flammable Waste (FW): (a)liq FW with flash pt <60°C or FW gas, diesel and light heating oils with flash pt >55°C and ≤75°C (b)pyrophoric liq/solid FW liable to ignite within 5 min after air contact (c)solid FW readily combustible or which may cause/contribute to fire by friction (d)gas FW which is F in air at 20°C and 101.3 kPa (e)water reactive FW which, in contact with water, emits F gases in dangerous quantities (f)other: aerosols, self-heating, organic peroxides and self-reactive FWs.
HP7 Carcinogenic: waste which induces cancer or increases its incidence.
HP11 Mutagenic: waste which may cause a mutation, that is a permanent change in the amount or structure of the genetic material in a cell.
649-119-00-5
306-004-1
95465-89-7
Flam. Gas 1
Carc. 1A
Muta. 1B
HP3 Flammable Waste (FW): (a)liq FW with flash pt <60°C or FW gas, diesel and light heating oils with flash pt >55°C and ≤75°C (b)pyrophoric liq/solid FW liable to ignite within 5 min after air contact (c)solid FW readily combustible or which may cause/contribute to fire by friction (d)gas FW which is F in air at 20°C and 101.3 kPa (e)water reactive FW which, in contact with water, emits F gases in dangerous quantities (f)other: aerosols, self-heating, organic peroxides and self-reactive FWs.
HP7 Carcinogenic: waste which induces cancer or increases its incidence.
HP11 Mutagenic: waste which may cause a mutation, that is a permanent change in the amount or structure of the genetic material in a cell.
649-118-00-X
A complex combination of hydrocarbons obtained by subjecting a liquified petroleum gas mix to a sweetening process to oxidize mercaptans or to remove acidic impurities. It consists predominantly of C4 saturated and unsaturated hydrocarbons.
295-463-0
92045-80-2
Flam. Gas 1
Carc. 1A
Muta. 1B
HP3 Flammable Waste (FW): (a)liq FW with flash pt <60°C or FW gas, diesel and light heating oils with flash pt >55°C and ≤75°C (b)pyrophoric liq/solid FW liable to ignite within 5 min after air contact (c)solid FW readily combustible or which may cause/contribute to fire by friction (d)gas FW which is F in air at 20°C and 101.3 kPa (e)water reactive FW which, in contact with water, emits F gases in dangerous quantities (f)other: aerosols, self-heating, organic peroxides and self-reactive FWs.
HP7 Carcinogenic: waste which induces cancer or increases its incidence.
HP11 Mutagenic: waste which may cause a mutation, that is a permanent change in the amount or structure of the genetic material in a cell.
649-117-00-4
A complex combination of hydrocarbons produced by the distillation of the products of a steam cracking process. It consists predominantly of hydrocarbons having a carbon number of C4, predominantly 1-butene and 2-butene, containing also butane and isobutene and boiling in the range of approximately minus 12°C to 5°C (10.4°F to 41°F).
295-405-4
92045-23-3
Flam. Gas 1
Carc. 1A
Muta. 1B
HP3 Flammable Waste (FW): (a)liq FW with flash pt <60°C or FW gas, diesel and light heating oils with flash pt >55°C and ≤75°C (b)pyrophoric liq/solid FW liable to ignite within 5 min after air contact (c)solid FW readily combustible or which may cause/contribute to fire by friction (d)gas FW which is F in air at 20°C and 101.3 kPa (e)water reactive FW which, in contact with water, emits F gases in dangerous quantities (f)other: aerosols, self-heating, organic peroxides and self-reactive FWs.
HP7 Carcinogenic: waste which induces cancer or increases its incidence.
HP11 Mutagenic: waste which may cause a mutation, that is a permanent change in the amount or structure of the genetic material in a cell.
649-116-00-9
A complex combination of hydrocarbons produced by the distillation of products from a steam cracking process. It consists predominantly of propylene with some propane and boils in the range of approximately minus 70°C to 0°C (minus 94°F to 32°F).
295-404-9
92045-22-2
Flam. Gas 1
Carc. 1A
Muta. 1B
HP3 Flammable Waste (FW): (a)liq FW with flash pt <60°C or FW gas, diesel and light heating oils with flash pt >55°C and ≤75°C (b)pyrophoric liq/solid FW liable to ignite within 5 min after air contact (c)solid FW readily combustible or which may cause/contribute to fire by friction (d)gas FW which is F in air at 20°C and 101.3 kPa (e)water reactive FW which, in contact with water, emits F gases in dangerous quantities (f)other: aerosols, self-heating, organic peroxides and self-reactive FWs.
HP7 Carcinogenic: waste which induces cancer or increases its incidence.
HP11 Mutagenic: waste which may cause a mutation, that is a permanent change in the amount or structure of the genetic material in a cell.
649-115-00-3
292-456-4
90622-55-2
Flam. Gas 1
Carc. 1A
Muta. 1B
HP3 Flammable Waste (FW): (a)liq FW with flash pt <60°C or FW gas, diesel and light heating oils with flash pt >55°C and ≤75°C (b)pyrophoric liq/solid FW liable to ignite within 5 min after air contact (c)solid FW readily combustible or which may cause/contribute to fire by friction (d)gas FW which is F in air at 20°C and 101.3 kPa (e)water reactive FW which, in contact with water, emits F gases in dangerous quantities (f)other: aerosols, self-heating, organic peroxides and self-reactive FWs.
HP7 Carcinogenic: waste which induces cancer or increases its incidence.
HP11 Mutagenic: waste which may cause a mutation, that is a permanent change in the amount or structure of the genetic material in a cell.
649-114-00-8
289-339-5
87741-01-3
Flam. Gas 1
Carc. 1A
Muta. 1B
HP3 Flammable Waste (FW): (a)liq FW with flash pt <60°C or FW gas, diesel and light heating oils with flash pt >55°C and ≤75°C (b)pyrophoric liq/solid FW liable to ignite within 5 min after air contact (c)solid FW readily combustible or which may cause/contribute to fire by friction (d)gas FW which is F in air at 20°C and 101.3 kPa (e)water reactive FW which, in contact with water, emits F gases in dangerous quantities (f)other: aerosols, self-heating, organic peroxides and self-reactive FWs.
HP7 Carcinogenic: waste which induces cancer or increases its incidence.
HP11 Mutagenic: waste which may cause a mutation, that is a permanent change in the amount or structure of the genetic material in a cell.
649-113-00-2
A complex combination of hydrocarbons obtained by the catalytic reforming of straight-run naphtha and the fractionation of the total effluent. It consists of saturated aliphatic hydrocarbons having carbon numbers predominantly in the range of C2 through C4.
273-270-2
68955-34-0
Flam. Gas 1
Carc. 1A
Muta. 1B
HP3 Flammable Waste (FW): (a)liq FW with flash pt <60°C or FW gas, diesel and light heating oils with flash pt >55°C and ≤75°C (b)pyrophoric liq/solid FW liable to ignite within 5 min after air contact (c)solid FW readily combustible or which may cause/contribute to fire by friction (d)gas FW which is F in air at 20°C and 101.3 kPa (e)water reactive FW which, in contact with water, emits F gases in dangerous quantities (f)other: aerosols, self-heating, organic peroxides and self-reactive FWs.
HP7 Carcinogenic: waste which induces cancer or increases its incidence.
HP11 Mutagenic: waste which may cause a mutation, that is a permanent change in the amount or structure of the genetic material in a cell.
649-112-00-7
A complex combination of hydrocarbons produced by the distillation of products from a thermal cracking process. It consists of hydrocarbons having a carbon number predominantly of C4.
273-265-5
68955-28-2
Flam. Gas 1
Carc. 1A
Muta. 1B
HP3 Flammable Waste (FW): (a)liq FW with flash pt <60°C or FW gas, diesel and light heating oils with flash pt >55°C and ≤75°C (b)pyrophoric liq/solid FW liable to ignite within 5 min after air contact (c)solid FW readily combustible or which may cause/contribute to fire by friction (d)gas FW which is F in air at 20°C and 101.3 kPa (e)water reactive FW which, in contact with water, emits F gases in dangerous quantities (f)other: aerosols, self-heating, organic peroxides and self-reactive FWs.
HP7 Carcinogenic: waste which induces cancer or increases its incidence.
HP11 Mutagenic: waste which may cause a mutation, that is a permanent change in the amount or structure of the genetic material in a cell.
649-111-00-1
A complex combination of hydrocarbons obtained from the fractionation stabilization of thermal cracked hydrocarbons from petroleum coking process. It consists of hydrocarbons having carbon numbers predominantly in the range of C1 through C6.
273-176-1
68952-82-9
Flam. Gas 1
Carc. 1A
Muta. 1B
HP3 Flammable Waste (FW): (a)liq FW with flash pt <60°C or FW gas, diesel and light heating oils with flash pt >55°C and ≤75°C (b)pyrophoric liq/solid FW liable to ignite within 5 min after air contact (c)solid FW readily combustible or which may cause/contribute to fire by friction (d)gas FW which is F in air at 20°C and 101.3 kPa (e)water reactive FW which, in contact with water, emits F gases in dangerous quantities (f)other: aerosols, self-heating, organic peroxides and self-reactive FWs.
HP7 Carcinogenic: waste which induces cancer or increases its incidence.
HP11 Mutagenic: waste which may cause a mutation, that is a permanent change in the amount or structure of the genetic material in a cell.
649-110-00-6
A complex combination of hydrocarbons obtained from the separation of thermal-cracked distillates, naphtha and gas oil. It consists predominantly of hydrocarbons having carbon numbers predominantly in the range of C1 through C6.
273-175-6
68952-81-8
Flam. Gas 1
Carc. 1A
Muta. 1B
HP3 Flammable Waste (FW): (a)liq FW with flash pt <60°C or FW gas, diesel and light heating oils with flash pt >55°C and ≤75°C (b)pyrophoric liq/solid FW liable to ignite within 5 min after air contact (c)solid FW readily combustible or which may cause/contribute to fire by friction (d)gas FW which is F in air at 20°C and 101.3 kPa (e)water reactive FW which, in contact with water, emits F gases in dangerous quantities (f)other: aerosols, self-heating, organic peroxides and self-reactive FWs.
HP7 Carcinogenic: waste which induces cancer or increases its incidence.
HP11 Mutagenic: waste which may cause a mutation, that is a permanent change in the amount or structure of the genetic material in a cell.
649-109-00-0
A complex combination of hydrocarbons obtained by the fractionation of catalytic cracked naphtha and distillate. It consists predominantly of hydrocarbons having carbon numbers predominantly in the range of C1 through C4.
273-170-9
68952-77-2
Flam. Gas 1
Carc. 1A
Muta. 1B
HP3 Flammable Waste (FW): (a)liq FW with flash pt <60°C or FW gas, diesel and light heating oils with flash pt >55°C and ≤75°C (b)pyrophoric liq/solid FW liable to ignite within 5 min after air contact (c)solid FW readily combustible or which may cause/contribute to fire by friction (d)gas FW which is F in air at 20°C and 101.3 kPa (e)water reactive FW which, in contact with water, emits F gases in dangerous quantities (f)other: aerosols, self-heating, organic peroxides and self-reactive FWs.
HP7 Carcinogenic: waste which induces cancer or increases its incidence.
HP11 Mutagenic: waste which may cause a mutation, that is a permanent change in the amount or structure of the genetic material in a cell.
649-108-00-5
A complex combination of hydrocarbons obtained from fractionation of catalytic cracked naphtha. It consists of hydrocarbons having carbon numbers predominantly in the range of C1 through C4.
273-169-3
68952-76-1
Flam. Gas 1
Carc. 1A
Muta. 1B
HP3 Flammable Waste (FW): (a)liq FW with flash pt <60°C or FW gas, diesel and light heating oils with flash pt >55°C and ≤75°C (b)pyrophoric liq/solid FW liable to ignite within 5 min after air contact (c)solid FW readily combustible or which may cause/contribute to fire by friction (d)gas FW which is F in air at 20°C and 101.3 kPa (e)water reactive FW which, in contact with water, emits F gases in dangerous quantities (f)other: aerosols, self-heating, organic peroxides and self-reactive FWs.
HP7 Carcinogenic: waste which induces cancer or increases its incidence.
HP11 Mutagenic: waste which may cause a mutation, that is a permanent change in the amount or structure of the genetic material in a cell.
649-107-00-X
A complex combination of hydrocarbons obtained from the fractionation of the liquid from the first tower used in the distillation of crude oil. It consists of saturated aliphatic hydrocarbons having carbon numbers predominantly in the range of C1 through C4.
272-883-2
68919-10-8
Flam. Gas 1
Carc. 1A
Muta. 1B
HP3 Flammable Waste (FW): (a)liq FW with flash pt <60°C or FW gas, diesel and light heating oils with flash pt >55°C and ≤75°C (b)pyrophoric liq/solid FW liable to ignite within 5 min after air contact (c)solid FW readily combustible or which may cause/contribute to fire by friction (d)gas FW which is F in air at 20°C and 101.3 kPa (e)water reactive FW which, in contact with water, emits F gases in dangerous quantities (f)other: aerosols, self-heating, organic peroxides and self-reactive FWs.
HP7 Carcinogenic: waste which induces cancer or increases its incidence.
HP11 Mutagenic: waste which may cause a mutation, that is a permanent change in the amount or structure of the genetic material in a cell.
649-106-00-4
A complex combination of hydrocarbons produced by the fractionation of the charge to the C3-C4 splitter. It consists predominantly of C3 hydrocarbons.
272-893-7
68919-20-0
Flam. Gas 1
Carc. 1A
Muta. 1B
HP3 Flammable Waste (FW): (a)liq FW with flash pt <60°C or FW gas, diesel and light heating oils with flash pt >55°C and ≤75°C (b)pyrophoric liq/solid FW liable to ignite within 5 min after air contact (c)solid FW readily combustible or which may cause/contribute to fire by friction (d)gas FW which is F in air at 20°C and 101.3 kPa (e)water reactive FW which, in contact with water, emits F gases in dangerous quantities (f)other: aerosols, self-heating, organic peroxides and self-reactive FWs.
HP7 Carcinogenic: waste which induces cancer or increases its incidence.
HP11 Mutagenic: waste which may cause a mutation, that is a permanent change in the amount or structure of the genetic material in a cell.
649-105-00-9
A complex combination of hydrocarbons obtained by the catalytic reforming of straight-run naphtha and fractionation of the total effluent. It consists of methane, ethane, and propane.
272-882-7
68919-09-5
Flam. Gas 1
Carc. 1A
Muta. 1B
HP3 Flammable Waste (FW): (a)liq FW with flash pt <60°C or FW gas, diesel and light heating oils with flash pt >55°C and ≤75°C (b)pyrophoric liq/solid FW liable to ignite within 5 min after air contact (c)solid FW readily combustible or which may cause/contribute to fire by friction (d)gas FW which is F in air at 20°C and 101.3 kPa (e)water reactive FW which, in contact with water, emits F gases in dangerous quantities (f)other: aerosols, self-heating, organic peroxides and self-reactive FWs.
HP7 Carcinogenic: waste which induces cancer or increases its incidence.
HP11 Mutagenic: waste which may cause a mutation, that is a permanent change in the amount or structure of the genetic material in a cell.
649-104-00-3
A complex combination of hydrocarbons produced by a naphtha unifiner desulfurization process and stripped from the naphtha product. It consists of saturated aliphatic hydrocarbons having carbon numbers predominantly in the range of C1 through C4.
272-879-0
68919-06-2
Flam. Gas 1
Carc. 1A
Muta. 1B
HP3 Flammable Waste (FW): (a)liq FW with flash pt <60°C or FW gas, diesel and light heating oils with flash pt >55°C and ≤75°C (b)pyrophoric liq/solid FW liable to ignite within 5 min after air contact (c)solid FW readily combustible or which may cause/contribute to fire by friction (d)gas FW which is F in air at 20°C and 101.3 kPa (e)water reactive FW which, in contact with water, emits F gases in dangerous quantities (f)other: aerosols, self-heating, organic peroxides and self-reactive FWs.
HP7 Carcinogenic: waste which induces cancer or increases its incidence.
HP11 Mutagenic: waste which may cause a mutation, that is a permanent change in the amount or structure of the genetic material in a cell.
649-103-00-8
A complex combination of hydrocarbons obtained by the fractionation of light straight-run gasoline. It consists of saturated aliphatic hydrocarbons having carbon numbers predominantly in the range of C1 through C5.
272-878-5
68919-05-1
Flam. Gas 1
Carc. 1A
Muta. 1B
HP3 Flammable Waste (FW): (a)liq FW with flash pt <60°C or FW gas, diesel and light heating oils with flash pt >55°C and ≤75°C (b)pyrophoric liq/solid FW liable to ignite within 5 min after air contact (c)solid FW readily combustible or which may cause/contribute to fire by friction (d)gas FW which is F in air at 20°C and 101.3 kPa (e)water reactive FW which, in contact with water, emits F gases in dangerous quantities (f)other: aerosols, self-heating, organic peroxides and self-reactive FWs.
HP7 Carcinogenic: waste which induces cancer or increases its incidence.
HP11 Mutagenic: waste which may cause a mutation, that is a permanent change in the amount or structure of the genetic material in a cell.
649-102-00-2
A complex combination of hydrocarbons obtained by the fractionation of combined naphtha streams. It consists of saturated aliphatic hydrocarbons having carbon numbers predominantly in the range of C1 through C5.
272-872-2
68919-00-6
Flam. Gas 1
Carc. 1A
Muta. 1B
HP3 Flammable Waste (FW): (a)liq FW with flash pt <60°C or FW gas, diesel and light heating oils with flash pt >55°C and ≤75°C (b)pyrophoric liq/solid FW liable to ignite within 5 min after air contact (c)solid FW readily combustible or which may cause/contribute to fire by friction (d)gas FW which is F in air at 20°C and 101.3 kPa (e)water reactive FW which, in contact with water, emits F gases in dangerous quantities (f)other: aerosols, self-heating, organic peroxides and self-reactive FWs.
HP7 Carcinogenic: waste which induces cancer or increases its incidence.
HP11 Mutagenic: waste which may cause a mutation, that is a permanent change in the amount or structure of the genetic material in a cell.
649-101-00-7
A complex combination of hydrocarbons produced by the fractionation of crude oil. It consists of saturated aliphatic hydrocarbons having carbon numbers predominantly in the range of C1 through C5.
272-871-7
68918-99-0
Flam. Gas 1
Carc. 1A
Muta. 1B
HP3 Flammable Waste (FW): (a)liq FW with flash pt <60°C or FW gas, diesel and light heating oils with flash pt >55°C and ≤75°C (b)pyrophoric liq/solid FW liable to ignite within 5 min after air contact (c)solid FW readily combustible or which may cause/contribute to fire by friction (d)gas FW which is F in air at 20°C and 101.3 kPa (e)water reactive FW which, in contact with water, emits F gases in dangerous quantities (f)other: aerosols, self-heating, organic peroxides and self-reactive FWs.
HP7 Carcinogenic: waste which induces cancer or increases its incidence.
HP11 Mutagenic: waste which may cause a mutation, that is a permanent change in the amount or structure of the genetic material in a cell.
649-100-00-1
A complex combination of hydrocarbons obtained by subjecting a petroleum distillate to a sweetening process to convert mercaptans or to remove acidic impurities. It consists predominantly of saturated and unsaturated hydrocarbons having carbon numbers predominantly in the range of C2 through C4 and boiling in the range of approximately -51°C to -34°C (-60°F to -30°F).
272-205-5
68783-65-3
Flam. Gas 1
Carc. 1A
Muta. 1B
HP3 Flammable Waste (FW): (a)liq FW with flash pt <60°C or FW gas, diesel and light heating oils with flash pt >55°C and ≤75°C (b)pyrophoric liq/solid FW liable to ignite within 5 min after air contact (c)solid FW readily combustible or which may cause/contribute to fire by friction (d)gas FW which is F in air at 20°C and 101.3 kPa (e)water reactive FW which, in contact with water, emits F gases in dangerous quantities (f)other: aerosols, self-heating, organic peroxides and self-reactive FWs.
HP7 Carcinogenic: waste which induces cancer or increases its incidence.
HP11 Mutagenic: waste which may cause a mutation, that is a permanent change in the amount or structure of the genetic material in a cell.
649-099-00-8
A complex combination of hydrocarbons produced by the distillation of the products from a catalytic cracking process. It consists predominantly of hydrocarbons having carbon numbers predominantly in the range of C3 through C5.
272-203-4
68783-64-2
Flam. Gas 1
Carc. 1A
Muta. 1B
HP3 Flammable Waste (FW): (a)liq FW with flash pt <60°C or FW gas, diesel and light heating oils with flash pt >55°C and ≤75°C (b)pyrophoric liq/solid FW liable to ignite within 5 min after air contact (c)solid FW readily combustible or which may cause/contribute to fire by friction (d)gas FW which is F in air at 20°C and 101.3 kPa (e)water reactive FW which, in contact with water, emits F gases in dangerous quantities (f)other: aerosols, self-heating, organic peroxides and self-reactive FWs.
HP7 Carcinogenic: waste which induces cancer or increases its incidence.
HP11 Mutagenic: waste which may cause a mutation, that is a permanent change in the amount or structure of the genetic material in a cell.
649-098-00-2
A complex combination obtained from various refinery processes. It consists of hydrogen, hydrogen sulfide and hydrocarbons having carbon numbers predominantly in the range of C1 through C5.
272-183-7
68783-07-3
Flam. Gas 1
Carc. 1A
Muta. 1B
HP3 Flammable Waste (FW): (a)liq FW with flash pt <60°C or FW gas, diesel and light heating oils with flash pt >55°C and ≤75°C (b)pyrophoric liq/solid FW liable to ignite within 5 min after air contact (c)solid FW readily combustible or which may cause/contribute to fire by friction (d)gas FW which is F in air at 20°C and 101.3 kPa (e)water reactive FW which, in contact with water, emits F gases in dangerous quantities (f)other: aerosols, self-heating, organic peroxides and self-reactive FWs.
HP7 Carcinogenic: waste which induces cancer or increases its incidence.
HP11 Mutagenic: waste which may cause a mutation, that is a permanent change in the amount or structure of the genetic material in a cell.
649-097-00-7
A complex combination of hydrocarbons obtained from the fractionation of depropanizer bottoms. It consists predominantly of butane, isobutane and butadiene.
271-742-2
68606-34-8
Flam. Gas 1
Carc. 1A
Muta. 1B
HP3 Flammable Waste (FW): (a)liq FW with flash pt <60°C or FW gas, diesel and light heating oils with flash pt >55°C and ≤75°C (b)pyrophoric liq/solid FW liable to ignite within 5 min after air contact (c)solid FW readily combustible or which may cause/contribute to fire by friction (d)gas FW which is F in air at 20°C and 101.3 kPa (e)water reactive FW which, in contact with water, emits F gases in dangerous quantities (f)other: aerosols, self-heating, organic peroxides and self-reactive FWs.
HP7 Carcinogenic: waste which induces cancer or increases its incidence.
HP11 Mutagenic: waste which may cause a mutation, that is a permanent change in the amount or structure of the genetic material in a cell.
649-096-00-1
A complex combination of hydrocarbons produced by the catalytic cracking of gas oil. It consists of hydrocarbons having carbon numbers predominantly in the range of C3 through C4.
271-737-5
68606-27-9
Flam. Gas 1
Carc. 1A
Muta. 1B
HP3 Flammable Waste (FW): (a)liq FW with flash pt <60°C or FW gas, diesel and light heating oils with flash pt >55°C and ≤75°C (b)pyrophoric liq/solid FW liable to ignite within 5 min after air contact (c)solid FW readily combustible or which may cause/contribute to fire by friction (d)gas FW which is F in air at 20°C and 101.3 kPa (e)water reactive FW which, in contact with water, emits F gases in dangerous quantities (f)other: aerosols, self-heating, organic peroxides and self-reactive FWs.
HP7 Carcinogenic: waste which induces cancer or increases its incidence.
HP11 Mutagenic: waste which may cause a mutation, that is a permanent change in the amount or structure of the genetic material in a cell.
649-095-00-6
271-735-4
68606-26-8
Flam. Gas 1
Carc. 1A
Muta. 1B
HP3 Flammable Waste (FW): (a)liq FW with flash pt <60°C or FW gas, diesel and light heating oils with flash pt >55°C and ≤75°C (b)pyrophoric liq/solid FW liable to ignite within 5 min after air contact (c)solid FW readily combustible or which may cause/contribute to fire by friction (d)gas FW which is F in air at 20°C and 101.3 kPa (e)water reactive FW which, in contact with water, emits F gases in dangerous quantities (f)other: aerosols, self-heating, organic peroxides and self-reactive FWs.
HP7 Carcinogenic: waste which induces cancer or increases its incidence.
HP11 Mutagenic: waste which may cause a mutation, that is a permanent change in the amount or structure of the genetic material in a cell.
649-094-00-0
271-734-9
68606-25-7
Flam. Gas 1
Carc. 1A
Muta. 1B
HP3 Flammable Waste (FW): (a)liq FW with flash pt <60°C or FW gas, diesel and light heating oils with flash pt >55°C and ≤75°C (b)pyrophoric liq/solid FW liable to ignite within 5 min after air contact (c)solid FW readily combustible or which may cause/contribute to fire by friction (d)gas FW which is F in air at 20°C and 101.3 kPa (e)water reactive FW which, in contact with water, emits F gases in dangerous quantities (f)other: aerosols, self-heating, organic peroxides and self-reactive FWs.
HP7 Carcinogenic: waste which induces cancer or increases its incidence.
HP11 Mutagenic: waste which may cause a mutation, that is a permanent change in the amount or structure of the genetic material in a cell.
649-093-00-5
A complex combination of hydrocarbons produced by the distillation of crude oil and/or the cracking of tower gas oil. It consists of hydrocarbons having carbon numbers predominantly in the range of C1 through C5.
271-624-0
68602-83-5
Flam. Gas 1
Carc. 1A
Muta. 1B
HP3 Flammable Waste (FW): (a)liq FW with flash pt <60°C or FW gas, diesel and light heating oils with flash pt >55°C and ≤75°C (b)pyrophoric liq/solid FW liable to ignite within 5 min after air contact (c)solid FW readily combustible or which may cause/contribute to fire by friction (d)gas FW which is F in air at 20°C and 101.3 kPa (e)water reactive FW which, in contact with water, emits F gases in dangerous quantities (f)other: aerosols, self-heating, organic peroxides and self-reactive FWs.
HP7 Carcinogenic: waste which induces cancer or increases its incidence.
HP11 Mutagenic: waste which may cause a mutation, that is a permanent change in the amount or structure of the genetic material in a cell.
649-092-00-X
271-261-8
68527-19-5
Flam. Gas 1
Carc. 1A
Muta. 1B
HP3 Flammable Waste (FW): (a)liq FW with flash pt <60°C or FW gas, diesel and light heating oils with flash pt >55°C and ≤75°C (b)pyrophoric liq/solid FW liable to ignite within 5 min after air contact (c)solid FW readily combustible or which may cause/contribute to fire by friction (d)gas FW which is F in air at 20°C and 101.3 kPa (e)water reactive FW which, in contact with water, emits F gases in dangerous quantities (f)other: aerosols, self-heating, organic peroxides and self-reactive FWs.
HP7 Carcinogenic: waste which induces cancer or increases its incidence.
HP11 Mutagenic: waste which may cause a mutation, that is a permanent change in the amount or structure of the genetic material in a cell.
649-091-00-4
A complex combination of hydrocarbons having carbon numbers predominantly in the range of C1 through C3 and boiling in the range of approximately minus 164°C to minus 42°C (-263°F to -44°F).
271-259-7
68527-16-2
Flam. Gas 1
Carc. 1A
Muta. 1B
HP3 Flammable Waste (FW): (a)liq FW with flash pt <60°C or FW gas, diesel and light heating oils with flash pt >55°C and ≤75°C (b)pyrophoric liq/solid FW liable to ignite within 5 min after air contact (c)solid FW readily combustible or which may cause/contribute to fire by friction (d)gas FW which is F in air at 20°C and 101.3 kPa (e)water reactive FW which, in contact with water, emits F gases in dangerous quantities (f)other: aerosols, self-heating, organic peroxides and self-reactive FWs.
HP7 Carcinogenic: waste which induces cancer or increases its incidence.
HP11 Mutagenic: waste which may cause a mutation, that is a permanent change in the amount or structure of the genetic material in a cell.
649-090-00-9
A complex combination of hydrocarbons obtained by subjecting hydrocarbon gases to a sweetening process to convert mercaptans or to remove acidic impurities. It consists of hydrocarbons having carbon numbers predominantly in the range of C1 through C4 and boiling in the range of approximately -164°C to -0.5°C(-263°F to 31°F).
271-038-5
68514-36-3
Flam. Gas 1
Carc. 1A
Muta. 1B
HP3 Flammable Waste (FW): (a)liq FW with flash pt <60°C or FW gas, diesel and light heating oils with flash pt >55°C and ≤75°C (b)pyrophoric liq/solid FW liable to ignite within 5 min after air contact (c)solid FW readily combustible or which may cause/contribute to fire by friction (d)gas FW which is F in air at 20°C and 101.3 kPa (e)water reactive FW which, in contact with water, emits F gases in dangerous quantities (f)other: aerosols, self-heating, organic peroxides and self-reactive FWs.
HP7 Carcinogenic: waste which induces cancer or increases its incidence.
HP11 Mutagenic: waste which may cause a mutation, that is a permanent change in the amount or structure of the genetic material in a cell.
649-089-00-3
A complex combination of hydrocarbons produced by thermal cracking and absorber operations and by distillation of crude oil. It consists of hydrocarbons having carbon numbers predominantly in the range of C1 through C4 and boiling in the range of approximately minus 164°C to minus 0.5°C (-263°F to 31°F).
271-032-2
68514-31-8
Flam. Gas 1
Carc. 1A
Muta. 1B
HP3 Flammable Waste (FW): (a)liq FW with flash pt <60°C or FW gas, diesel and light heating oils with flash pt >55°C and ≤75°C (b)pyrophoric liq/solid FW liable to ignite within 5 min after air contact (c)solid FW readily combustible or which may cause/contribute to fire by friction (d)gas FW which is F in air at 20°C and 101.3 kPa (e)water reactive FW which, in contact with water, emits F gases in dangerous quantities (f)other: aerosols, self-heating, organic peroxides and self-reactive FWs.
HP7 Carcinogenic: waste which induces cancer or increases its incidence.
HP11 Mutagenic: waste which may cause a mutation, that is a permanent change in the amount or structure of the genetic material in a cell.
649-088-00-8
A complex residuum from the distillation of streams from various refinery operations. It consists of hydrocarbons having carbon numbers in the range of C4 through C5, predominantly butane and boiling in the range of approximately -11.7°C to 27.8°C (11°F to 82°F).
271-010-2
68513-66-6
Flam. Gas 1
Carc. 1A
Muta. 1B
HP3 Flammable Waste (FW): (a)liq FW with flash pt <60°C or FW gas, diesel and light heating oils with flash pt >55°C and ≤75°C (b)pyrophoric liq/solid FW liable to ignite within 5 min after air contact (c)solid FW readily combustible or which may cause/contribute to fire by friction (d)gas FW which is F in air at 20°C and 101.3 kPa (e)water reactive FW which, in contact with water, emits F gases in dangerous quantities (f)other: aerosols, self-heating, organic peroxides and self-reactive FWs.
HP7 Carcinogenic: waste which induces cancer or increases its incidence.
HP11 Mutagenic: waste which may cause a mutation, that is a permanent change in the amount or structure of the genetic material in a cell.
649-087-00-2
A complex combination of hydrocarbons obtained by the stabilization of light straight-run naphtha. It consists of saturated aliphatic hydrocarbons having carbon numbers predominantly in the range of C2 through C6.
271-002-9
68513-17-7
Flam. Gas 1
Carc. 1A
Muta. 1B
HP3 Flammable Waste (FW): (a)liq FW with flash pt <60°C or FW gas, diesel and light heating oils with flash pt >55°C and ≤75°C (b)pyrophoric liq/solid FW liable to ignite within 5 min after air contact (c)solid FW readily combustible or which may cause/contribute to fire by friction (d)gas FW which is F in air at 20°C and 101.3 kPa (e)water reactive FW which, in contact with water, emits F gases in dangerous quantities (f)other: aerosols, self-heating, organic peroxides and self-reactive FWs.
HP7 Carcinogenic: waste which induces cancer or increases its incidence.
HP11 Mutagenic: waste which may cause a mutation, that is a permanent change in the amount or structure of the genetic material in a cell.
649-086-00-7
A complex combination of hydrocarbon produced by the distillation of products from a hydrocracking process. It consists predominantly of hydrocarbons having carbon numbers predominantly in the range of C1 through C4. It may also contain small amounts of hydrogen and hydrogen sulfide.
271-001-3
68513-16-6
Flam. Gas 1
Carc. 1A
Muta. 1B
HP3 Flammable Waste (FW): (a)liq FW with flash pt <60°C or FW gas, diesel and light heating oils with flash pt >55°C and ≤75°C (b)pyrophoric liq/solid FW liable to ignite within 5 min after air contact (c)solid FW readily combustible or which may cause/contribute to fire by friction (d)gas FW which is F in air at 20°C and 101.3 kPa (e)water reactive FW which, in contact with water, emits F gases in dangerous quantities (f)other: aerosols, self-heating, organic peroxides and self-reactive FWs.
HP7 Carcinogenic: waste which induces cancer or increases its incidence.
HP11 Mutagenic: waste which may cause a mutation, that is a permanent change in the amount or structure of the genetic material in a cell.
649-085-00-1
A complex combination of hydrocarbons obtained by the fractionation of the full-range straight-run naphtha. It consists of hydrocarbons having carbon numbers predominantly in the range of C2 through C6.
271-000-8
68513-15-5
Flam. Gas 1
Carc. 1A
Muta. 1B
HP3 Flammable Waste (FW): (a)liq FW with flash pt <60°C or FW gas, diesel and light heating oils with flash pt >55°C and ≤75°C (b)pyrophoric liq/solid FW liable to ignite within 5 min after air contact (c)solid FW readily combustible or which may cause/contribute to fire by friction (d)gas FW which is F in air at 20°C and 101.3 kPa (e)water reactive FW which, in contact with water, emits F gases in dangerous quantities (f)other: aerosols, self-heating, organic peroxides and self-reactive FWs.
HP7 Carcinogenic: waste which induces cancer or increases its incidence.
HP11 Mutagenic: waste which may cause a mutation, that is a permanent change in the amount or structure of the genetic material in a cell.
649-084-00-6
A complex combination of hydrocarbons produced by distillation and condensation of crude oil. It consists of hydrocarbons having carbon numbers in the range of C3 through C5, predominantly C3 through C4.
270-990-9
68512-91-4
Flam. Gas 1
Carc. 1A
Muta. 1B
HP3 Flammable Waste (FW): (a)liq FW with flash pt <60°C or FW gas, diesel and light heating oils with flash pt >55°C and ≤75°C (b)pyrophoric liq/solid FW liable to ignite within 5 min after air contact (c)solid FW readily combustible or which may cause/contribute to fire by friction (d)gas FW which is F in air at 20°C and 101.3 kPa (e)water reactive FW which, in contact with water, emits F gases in dangerous quantities (f)other: aerosols, self-heating, organic peroxides and self-reactive FWs.
HP7 Carcinogenic: waste which induces cancer or increases its incidence.
HP11 Mutagenic: waste which may cause a mutation, that is a permanent change in the amount or structure of the genetic material in a cell.
649-083-00-0
A complex combination of hydrocarbons obtained from the thermal cracking of vacuum residues. It consists of hydrocarbons having carbon numbers predominantly in the range of C1 through C5.
270-815-6
68478-34-2
Flam. Gas 1
Carc. 1A
Muta. 1B
HP3 Flammable Waste (FW): (a)liq FW with flash pt <60°C or FW gas, diesel and light heating oils with flash pt >55°C and ≤75°C (b)pyrophoric liq/solid FW liable to ignite within 5 min after air contact (c)solid FW readily combustible or which may cause/contribute to fire by friction (d)gas FW which is F in air at 20°C and 101.3 kPa (e)water reactive FW which, in contact with water, emits F gases in dangerous quantities (f)other: aerosols, self-heating, organic peroxides and self-reactive FWs.
HP7 Carcinogenic: waste which induces cancer or increases its incidence.
HP11 Mutagenic: waste which may cause a mutation, that is a permanent change in the amount or structure of the genetic material in a cell.
649-082-00-5
A complex combination of hydrocarbons obtained from fractionation of distillate tail gas, straight-run naphtha, catalytic reformed naphtha stabilizer tail gas. It consists predominantly of hydrocarbons having carbon numbers in the range of C1 through C5, predominantly methane and ethane.
270-814-0
68478-33-1
Flam. Gas 1
Carc. 1A
Muta. 1B
HP3 Flammable Waste (FW): (a)liq FW with flash pt <60°C or FW gas, diesel and light heating oils with flash pt >55°C and ≤75°C (b)pyrophoric liq/solid FW liable to ignite within 5 min after air contact (c)solid FW readily combustible or which may cause/contribute to fire by friction (d)gas FW which is F in air at 20°C and 101.3 kPa (e)water reactive FW which, in contact with water, emits F gases in dangerous quantities (f)other: aerosols, self-heating, organic peroxides and self-reactive FWs.
HP7 Carcinogenic: waste which induces cancer or increases its incidence.
HP11 Mutagenic: waste which may cause a mutation, that is a permanent change in the amount or structure of the genetic material in a cell.
649-081-00-X
A complex combination of hydrocarbons obtained from the fractionation stabilization of straight-run naphtha, distillation tail gas and catalytic reformed naphtha stabilizer tail gas. It consists of hydrocarbons having carbon numbers in the range of C3 through C6, predominantly butane and isobutane.
270-813-5
68478-32-0
Flam. Gas 1
Carc. 1A
Muta. 1B
HP3 Flammable Waste (FW): (a)liq FW with flash pt <60°C or FW gas, diesel and light heating oils with flash pt >55°C and ≤75°C (b)pyrophoric liq/solid FW liable to ignite within 5 min after air contact (c)solid FW readily combustible or which may cause/contribute to fire by friction (d)gas FW which is F in air at 20°C and 101.3 kPa (e)water reactive FW which, in contact with water, emits F gases in dangerous quantities (f)other: aerosols, self-heating, organic peroxides and self-reactive FWs.
HP7 Carcinogenic: waste which induces cancer or increases its incidence.
HP11 Mutagenic: waste which may cause a mutation, that is a permanent change in the amount or structure of the genetic material in a cell.
649-080-00-4
A complex combination of hydrocarbons obtained from the fractionation stabilization of catalytic reformed naphtha. It consists predominantly of hydrocarbons having carbon numbers predominantly in the range of C1 through C4.
270-806-7
68478-26-2
Flam. Gas 1
Carc. 1A
Muta. 1B
HP3 Flammable Waste (FW): (a)liq FW with flash pt <60°C or FW gas, diesel and light heating oils with flash pt >55°C and ≤75°C (b)pyrophoric liq/solid FW liable to ignite within 5 min after air contact (c)solid FW readily combustible or which may cause/contribute to fire by friction (d)gas FW which is F in air at 20°C and 101.3 kPa (e)water reactive FW which, in contact with water, emits F gases in dangerous quantities (f)other: aerosols, self-heating, organic peroxides and self-reactive FWs.
HP7 Carcinogenic: waste which induces cancer or increases its incidence.
HP11 Mutagenic: waste which may cause a mutation, that is a permanent change in the amount or structure of the genetic material in a cell.
649-079-00-9
A complex combination of hydrocarbons obtained from the fractionation of products from catalytic cracking, catalytic reforming and hydrodesulfurizing processes treated to remove acidic impurities. It consists predominantly of hydrocarbons having carbon numbers predominantly in the range of C1 through C5.
270-804-6
68478-24-0
Flam. Gas 1
Carc. 1A
Muta. 1B
HP3 Flammable Waste (FW): (a)liq FW with flash pt <60°C or FW gas, diesel and light heating oils with flash pt >55°C and ≤75°C (b)pyrophoric liq/solid FW liable to ignite within 5 min after air contact (c)solid FW readily combustible or which may cause/contribute to fire by friction (d)gas FW which is F in air at 20°C and 101.3 kPa (e)water reactive FW which, in contact with water, emits F gases in dangerous quantities (f)other: aerosols, self-heating, organic peroxides and self-reactive FWs.
HP7 Carcinogenic: waste which induces cancer or increases its incidence.
HP11 Mutagenic: waste which may cause a mutation, that is a permanent change in the amount or structure of the genetic material in a cell.
649-078-00-3
A complex combination of hydrocarbons obtained from the stabilization of catalytic cracked naphtha. It consists predominantly of hydrocarbons having carbon numbers predominantly in the range of C1 through C6.
270-803-0
68478-22-8
Flam. Gas 1
Carc. 1A
Muta. 1B
HP3 Flammable Waste (FW): (a)liq FW with flash pt <60°C or FW gas, diesel and light heating oils with flash pt >55°C and ≤75°C (b)pyrophoric liq/solid FW liable to ignite within 5 min after air contact (c)solid FW readily combustible or which may cause/contribute to fire by friction (d)gas FW which is F in air at 20°C and 101.3 kPa (e)water reactive FW which, in contact with water, emits F gases in dangerous quantities (f)other: aerosols, self-heating, organic peroxides and self-reactive FWs.
HP7 Carcinogenic: waste which induces cancer or increases its incidence.
HP11 Mutagenic: waste which may cause a mutation, that is a permanent change in the amount or structure of the genetic material in a cell.
649-077-00-8
A complex combination of hydrocarbons obtained from fractionation of catalytic cracked clarified oil and thermal cracked vacuum residue. It consists predominantly of hydrocarbons having carbon numbers predominantly in the range of C1 through C6.
270-802-5
68478-21-7
Flam. Gas 1
Carc. 1A
Muta. 1B
HP3 Flammable Waste (FW): (a)liq FW with flash pt <60°C or FW gas, diesel and light heating oils with flash pt >55°C and ≤75°C (b)pyrophoric liq/solid FW liable to ignite within 5 min after air contact (c)solid FW readily combustible or which may cause/contribute to fire by friction (d)gas FW which is F in air at 20°C and 101.3 kPa (e)water reactive FW which, in contact with water, emits F gases in dangerous quantities (f)other: aerosols, self-heating, organic peroxides and self-reactive FWs.
HP7 Carcinogenic: waste which induces cancer or increases its incidence.
HP11 Mutagenic: waste which may cause a mutation, that is a permanent change in the amount or structure of the genetic material in a cell.
649-076-00-2
270-782-8
68477-99-6
Flam. Gas 1
Carc. 1A
Muta. 1B
HP3 Flammable Waste (FW): (a)liq FW with flash pt <60°C or FW gas, diesel and light heating oils with flash pt >55°C and ≤75°C (b)pyrophoric liq/solid FW liable to ignite within 5 min after air contact (c)solid FW readily combustible or which may cause/contribute to fire by friction (d)gas FW which is F in air at 20°C and 101.3 kPa (e)water reactive FW which, in contact with water, emits F gases in dangerous quantities (f)other: aerosols, self-heating, organic peroxides and self-reactive FWs.
HP7 Carcinogenic: waste which induces cancer or increases its incidence.
HP11 Mutagenic: waste which may cause a mutation, that is a permanent change in the amount or structure of the genetic material in a cell.
649-075-00-7
A complex combination of hydrocarbons that is used as the feed into the Girbatol unit to remove hydrogen sulfide. It consists of aliphatic hydrocarbons having carbon numbers predominantly in the range of C2 through C4.
270-778-6
68477-95-2
Flam. Gas 1
Carc. 1A
Muta. 1B
HP3 Flammable Waste (FW): (a)liq FW with flash pt <60°C or FW gas, diesel and light heating oils with flash pt >55°C and ≤75°C (b)pyrophoric liq/solid FW liable to ignite within 5 min after air contact (c)solid FW readily combustible or which may cause/contribute to fire by friction (d)gas FW which is F in air at 20°C and 101.3 kPa (e)water reactive FW which, in contact with water, emits F gases in dangerous quantities (f)other: aerosols, self-heating, organic peroxides and self-reactive FWs.
HP7 Carcinogenic: waste which induces cancer or increases its incidence.
HP11 Mutagenic: waste which may cause a mutation, that is a permanent change in the amount or structure of the genetic material in a cell.
649-074-00-1
A complex combination of hydrocarbons obtained by fractionation of miscellaneous hydrocarbon streams. It consists predominantly of hydrocarbons having carbon numbers in the range of C1 through C4, predominantly propane.
270-777-0
68477-94-1
Flam. Gas 1
Carc. 1A
Muta. 1B
HP3 Flammable Waste (FW): (a)liq FW with flash pt <60°C or FW gas, diesel and light heating oils with flash pt >55°C and ≤75°C (b)pyrophoric liq/solid FW liable to ignite within 5 min after air contact (c)solid FW readily combustible or which may cause/contribute to fire by friction (d)gas FW which is F in air at 20°C and 101.3 kPa (e)water reactive FW which, in contact with water, emits F gases in dangerous quantities (f)other: aerosols, self-heating, organic peroxides and self-reactive FWs.
HP7 Carcinogenic: waste which induces cancer or increases its incidence.
HP11 Mutagenic: waste which may cause a mutation, that is a permanent change in the amount or structure of the genetic material in a cell.
649-073-00-6
A complex combination of hydrocarbons produced by distillation of products from the gas and gasoline fractions of a catalytic cracking process. It consists of aliphatic hydrocarbons having carbon numbers predominantly in the range of C2 through C4.
270-773-9
68477-91-8
Flam. Gas 1
Carc. 1A
Muta. 1B
HP3 Flammable Waste (FW): (a)liq FW with flash pt <60°C or FW gas, diesel and light heating oils with flash pt >55°C and ≤75°C (b)pyrophoric liq/solid FW liable to ignite within 5 min after air contact (c)solid FW readily combustible or which may cause/contribute to fire by friction (d)gas FW which is F in air at 20°C and 101.3 kPa (e)water reactive FW which, in contact with water, emits F gases in dangerous quantities (f)other: aerosols, self-heating, organic peroxides and self-reactive FWs.
HP7 Carcinogenic: waste which induces cancer or increases its incidence.
HP11 Mutagenic: waste which may cause a mutation, that is a permanent change in the amount or structure of the genetic material in a cell.
649-072-00-0
A complex combination of hydrocarbons produced by the distillation of products from the gas and gasoline fractions of a catalytic cracking process. It consists predominantly of propylene with some ethane and propane.
270-772-3
68477-90-7
Flam. Gas 1
Carc. 1A
Muta. 1B
HP3 Flammable Waste (FW): (a)liq FW with flash pt <60°C or FW gas, diesel and light heating oils with flash pt >55°C and ≤75°C (b)pyrophoric liq/solid FW liable to ignite within 5 min after air contact (c)solid FW readily combustible or which may cause/contribute to fire by friction (d)gas FW which is F in air at 20°C and 101.3 kPa (e)water reactive FW which, in contact with water, emits F gases in dangerous quantities (f)other: aerosols, self-heating, organic peroxides and self-reactive FWs.
HP7 Carcinogenic: waste which induces cancer or increases its incidence.
HP11 Mutagenic: waste which may cause a mutation, that is a permanent change in the amount or structure of the genetic material in a cell.
649-071-00-5
A complex combination of hydrocarbons produced by the atmospheric distillation of a butane-butylene stream. It consists of aliphatic hydrocarbons having carbon numbers predominantly in the range of C3 through C4.
270-769-7
68477-87-2
Flam. Gas 1
Carc. 1A
Muta. 1B
HP3 Flammable Waste (FW): (a)liq FW with flash pt <60°C or FW gas, diesel and light heating oils with flash pt >55°C and ≤75°C (b)pyrophoric liq/solid FW liable to ignite within 5 min after air contact (c)solid FW readily combustible or which may cause/contribute to fire by friction (d)gas FW which is F in air at 20°C and 101.3 kPa (e)water reactive FW which, in contact with water, emits F gases in dangerous quantities (f)other: aerosols, self-heating, organic peroxides and self-reactive FWs.
HP7 Carcinogenic: waste which induces cancer or increases its incidence.
HP11 Mutagenic: waste which may cause a mutation, that is a permanent change in the amount or structure of the genetic material in a cell.
649-070-00-X
A complex combination of hydrocarbons produced from distillation of the gas and gasoline fractions from the catalytic cracking process. It contains predominantly ethane and ethylene.
270-768-1
68477-86-1
Flam. Gas 1
Carc. 1A
Muta. 1B
HP3 Flammable Waste (FW): (a)liq FW with flash pt <60°C or FW gas, diesel and light heating oils with flash pt >55°C and ≤75°C (b)pyrophoric liq/solid FW liable to ignite within 5 min after air contact (c)solid FW readily combustible or which may cause/contribute to fire by friction (d)gas FW which is F in air at 20°C and 101.3 kPa (e)water reactive FW which, in contact with water, emits F gases in dangerous quantities (f)other: aerosols, self-heating, organic peroxides and self-reactive FWs.
HP7 Carcinogenic: waste which induces cancer or increases its incidence.
HP11 Mutagenic: waste which may cause a mutation, that is a permanent change in the amount or structure of the genetic material in a cell.
649-069-00-4
A complex combination of hydrocarbons produced by distillation of products from a catalytic fractionation process. It consists of aliphatic hydrocarbons having carbon numbers in the range of C3 through C5, predominantly C4.
270-767-6
68477-85-0
Flam. Gas 1
Carc. 1A
Muta. 1B
HP3 Flammable Waste (FW): (a)liq FW with flash pt <60°C or FW gas, diesel and light heating oils with flash pt >55°C and ≤75°C (b)pyrophoric liq/solid FW liable to ignite within 5 min after air contact (c)solid FW readily combustible or which may cause/contribute to fire by friction (d)gas FW which is F in air at 20°C and 101.3 kPa (e)water reactive FW which, in contact with water, emits F gases in dangerous quantities (f)other: aerosols, self-heating, organic peroxides and self-reactive FWs.
HP7 Carcinogenic: waste which induces cancer or increases its incidence.
HP11 Mutagenic: waste which may cause a mutation, that is a permanent change in the amount or structure of the genetic material in a cell.
649-068-00-9
A complex combination of olefinic and paraffinic hydrocarbons having carbon numbers in the range of C3 through C5 which are used as alkylation feed. Ambient temperatures normally exceed the critical temperature of these combinations.
270-765-5
68477-83-8
Flam. Gas 1
Carc. 1A
Muta. 1B
HP3 Flammable Waste (FW): (a)liq FW with flash pt <60°C or FW gas, diesel and light heating oils with flash pt >55°C and ≤75°C (b)pyrophoric liq/solid FW liable to ignite within 5 min after air contact (c)solid FW readily combustible or which may cause/contribute to fire by friction (d)gas FW which is F in air at 20°C and 101.3 kPa (e)water reactive FW which, in contact with water, emits F gases in dangerous quantities (f)other: aerosols, self-heating, organic peroxides and self-reactive FWs.
HP7 Carcinogenic: waste which induces cancer or increases its incidence.
HP11 Mutagenic: waste which may cause a mutation, that is a permanent change in the amount or structure of the genetic material in a cell.
649-067-00-3
A complex combination of hydrocarbons produced by distillation of products from a catalytic reforming process. It consists of hydrocarbons having carbon numbers in the range of C1 through C6, predominantly C1 through C4.
270-760-8
68477-79-2
Flam. Gas 1
Carc. 1A
Muta. 1B
HP3 Flammable Waste (FW): (a)liq FW with flash pt <60°C or FW gas, diesel and light heating oils with flash pt >55°C and ≤75°C (b)pyrophoric liq/solid FW liable to ignite within 5 min after air contact (c)solid FW readily combustible or which may cause/contribute to fire by friction (d)gas FW which is F in air at 20°C and 101.3 kPa (e)water reactive FW which, in contact with water, emits F gases in dangerous quantities (f)other: aerosols, self-heating, organic peroxides and self-reactive FWs.
HP7 Carcinogenic: waste which induces cancer or increases its incidence.
HP11 Mutagenic: waste which may cause a mutation, that is a permanent change in the amount or structure of the genetic material in a cell.
649-066-00-8
A complex combination of hydrocarbons obtained from the fractionation stabilization of catalytic polymerized naphtha. It consists of aliphatic hydrocarbons having carbon numbers in the range of C2 through C6, predominantly C2 through C4.
270-758-7
68477-76-9
Flam. Gas 1
Carc. 1A
Muta. 1B
HP3 Flammable Waste (FW): (a)liq FW with flash pt <60°C or FW gas, diesel and light heating oils with flash pt >55°C and ≤75°C (b)pyrophoric liq/solid FW liable to ignite within 5 min after air contact (c)solid FW readily combustible or which may cause/contribute to fire by friction (d)gas FW which is F in air at 20°C and 101.3 kPa (e)water reactive FW which, in contact with water, emits F gases in dangerous quantities (f)other: aerosols, self-heating, organic peroxides and self-reactive FWs.
HP7 Carcinogenic: waste which induces cancer or increases its incidence.
HP11 Mutagenic: waste which may cause a mutation, that is a permanent change in the amount or structure of the genetic material in a cell.
649-065-00-2
A complex combination of hydrocarbons produced by the distillation of products from a catalytic cracking process. It consists of aliphatic hydrocarbons having carbon numbers in the range of C1 through C6, predominantly C1 through C5.
270-757-1
68477-75-8
Flam. Gas 1
Carc. 1A
Muta. 1B
HP3 Flammable Waste (FW): (a)liq FW with flash pt <60°C or FW gas, diesel and light heating oils with flash pt >55°C and ≤75°C (b)pyrophoric liq/solid FW liable to ignite within 5 min after air contact (c)solid FW readily combustible or which may cause/contribute to fire by friction (d)gas FW which is F in air at 20°C and 101.3 kPa (e)water reactive FW which, in contact with water, emits F gases in dangerous quantities (f)other: aerosols, self-heating, organic peroxides and self-reactive FWs.
HP7 Carcinogenic: waste which induces cancer or increases its incidence.
HP11 Mutagenic: waste which may cause a mutation, that is a permanent change in the amount or structure of the genetic material in a cell.
649-064-00-7
A complex combination of hydrocarbons produced by the distillation of the products from a catalytic cracking process. It consists predominantly of aliphatic hydrocarbons having carbon numbers predominantly in the range of C1 through C6.
270-756-6
68477-74-7
Flam. Gas 1
Carc. 1A
Muta. 1B
HP3 Flammable Waste (FW): (a)liq FW with flash pt <60°C or FW gas, diesel and light heating oils with flash pt >55°C and ≤75°C (b)pyrophoric liq/solid FW liable to ignite within 5 min after air contact (c)solid FW readily combustible or which may cause/contribute to fire by friction (d)gas FW which is F in air at 20°C and 101.3 kPa (e)water reactive FW which, in contact with water, emits F gases in dangerous quantities (f)other: aerosols, self-heating, organic peroxides and self-reactive FWs.
HP7 Carcinogenic: waste which induces cancer or increases its incidence.
HP11 Mutagenic: waste which may cause a mutation, that is a permanent change in the amount or structure of the genetic material in a cell.
649-063-00-1
A complex combination of hydrocarbons obtained from fractionation of catalytic cracked hydrocarbons and treated to remove acidic impurities. It consists of hydrocarbons having carbon numbers in the range of C2 through C4, predominantly C3.
270-755-0
68477-73-6
Flam. Gas 1
Carc. 1A
Muta. 1B
HP3 Flammable Waste (FW): (a)liq FW with flash pt <60°C or FW gas, diesel and light heating oils with flash pt >55°C and ≤75°C (b)pyrophoric liq/solid FW liable to ignite within 5 min after air contact (c)solid FW readily combustible or which may cause/contribute to fire by friction (d)gas FW which is F in air at 20°C and 101.3 kPa (e)water reactive FW which, in contact with water, emits F gases in dangerous quantities (f)other: aerosols, self-heating, organic peroxides and self-reactive FWs.
HP7 Carcinogenic: waste which induces cancer or increases its incidence.
HP11 Mutagenic: waste which may cause a mutation, that is a permanent change in the amount or structure of the genetic material in a cell.
649-062-00-6
A complex combination of hydrocarbons produced by a treating process to remove acidic materials. It consists of hydrocarbons having carbon numbers predominantly in the range of C15 through C30 and produces a finished oil with a viscosity of less than 100 SUS at 100°F (19cSt at 40°C). It contains relatively few normal paraffins.
265-136-7
64742-35-4
Carc. 1A
HP7 Carcinogenic: waste which induces cancer or increases its incidence.
649-061-00-0
A complex combination of hydrocarbons produced by a treating process to remove acidic materials. It consists of hydrocarbons having carbon numbers predominantly in the range of C20 through C50 and produces a finished oil with a viscosity of at least 100 SUS at 100°F (19cSt at 40°C). It contains relatively few normal paraffins.
265-135-1
64742-34-3
Carc. 1A
HP7 Carcinogenic: waste which induces cancer or increases its incidence.
649-060-00-5
A complex combination of hydrocarbons produced by a treating process to remove acidic materials. It consists of hydrocarbons having carbon numbers predominantly in the range of C15 through C30 and produces a finished oil with a viscosity less than 100 SUS at 100°F (19cSt at 40°C).
265-128-3
64742-28-5
Carc. 1A
HP7 Carcinogenic: waste which induces cancer or increases its incidence.
649-059-00-X
A complex combination of hydrocarbons obtained from a treating process to remove acidic materials. It consists predominantly of hydrocarbons having carbon numbers predominantly in the range of C20 through C50 and produces a finished oil with a viscosity of at least 100 SUS at 100°F (19cSt at 40°C). It contains a relatively large proportion of aliphatic hydrocarbons.
265-127-8
64742-27-4
Carc. 1A
HP7 Carcinogenic: waste which induces cancer or increases its incidence.
649-058-00-4
A complex combination of hydrocarbons obtained as a raffinate from a sulfuric acid treating process. It consists predominantly of saturated hydrocarbons having carbon numbers predominantly in the range of C15 through C30 and produces a finished oil having a viscosity of less than 100 SUS at 100°F (19cSt at 40°C).
265-121-5
64742-21-8
Carc. 1A
HP7 Carcinogenic: waste which induces cancer or increases its incidence.
649-057-00-9
A complex combination of hydrocarbons obtained as a raffinate from a sulfuric acid process. It consists predominantly of saturated hydrocarbons having carbon numbers predominantly in the range of C20 through C50 and produces a finished oil having a viscosity of at least 100 SUS at 100°F (19cSt at 40°C).
265-119-4
64742-20-7
Carc. 1A
HP7 Carcinogenic: waste which induces cancer or increases its incidence.
649-056-00-3
A complex combination of hydrocarbons obtained as a raffinate from a sulfuric acid treating process. It consists of hydrocarbons having carbon numbers predominantly in the range of C15 through C30 and produces a finished oil with a viscosity of less than 100 SUS at 100°F (19cSt at 40°C). It contains relatively few normal paraffins.
265-118-9
64742-19-4
Carc. 1A
HP7 Carcinogenic: waste which induces cancer or increases its incidence.
649-055-00-8
A complex combination of hydrocarbons obtained as a raffinate from a sulfuric acid treating process. It consists of hydrocarbons having carbon numbers predominantly in the range of C20 through C50 and produces a finished oil with a viscosity of at least 100 SUS at 100°F (19cSt at 40°C). It contains relatively few normal paraffins.
265-117-3
64742-18-3
Carc. 1A
HP7 Carcinogenic: waste which induces cancer or increases its incidence.
649-054-00-2
A complex combination of hydrocarbons produced by vacuum distillation of the residuum from atmospheric distillation of crude oil. It consists of hydrocarbons having carbon numbers predominantly in the range of C20 through C50 and produces a finished oil with a viscosity of at least 100 SUS at 100°F (19cSt at 40°C). It contains relatively few normal paraffins.
265-054-1
64741-53-3
Carc. 1A
HP7 Carcinogenic: waste which induces cancer or increases its incidence.
649-053-00-7
A complex combination of hydrocarbons produced by vacuum distillation of the residuum from atmospheric distillation of crude oil. It consists of hydrocarbons having carbon numbers predominantly in the range of C15 through C30 and produces a finished oil with a viscosity of less than 100 SUS at 100°F (19cSt at 40°C). It contains relatively few normal paraffins.
265-053-6
64741-52-2
Carc. 1A
HP7 Carcinogenic: waste which induces cancer or increases its incidence.
649-052-00-1
A complex combination of hydrocarbons produced by vacuum distillation of the residuum from atmospheric distillation of crude oil. It consists of hydrocarbons having carbon numbers predominantly in the range of C20 through C50 and produces a finished oil with a viscosity of at least 100 SUS at 100°F (19cSt at 40°C). It contains a relatively large proportion of saturated aliphatic hydrocarbons.
265-052-0
64741-51-1
Carc. 1A
HP7 Carcinogenic: waste which induces cancer or increases its incidence.
649-051-00-6
A complex combination of hydrocarbons produced by vacuum distillation of the residuum from atmospheric distillation of crude oil. It consists of hydrocarbons having carbon numbers predominantly in the range of C15 through C30 and produces a finished oil with a viscosity of less than 100 SUS at 100°F (19cSt at 40°C). It contains a relatively large proportion of saturated aliphatic hydrocarbons normally present in this distillation range of crude oil.
265-051-5
64741-50-0
Carc. 1A
HP7 Carcinogenic: waste which induces cancer or increases its incidence.
649-050-00-0
A complex combination of hydrocarbons. It consists predominantly of aliphatic, alicyclic and aromatic hydrocarbons. It may also contain small amounts of nitrogen, oxygen and sulfur compounds. This category encompasses light, medium, and heavy petroleums, as well as the oils extracted from tar sands. Hydrocarbonaceous materials requiring major chemical changes for their recovery or conversion to petroleum refinery feedstocks such as crude shale oils, upgraded shale oils and liquid coal fuels are not included in this definition.
232-298-5
8002-05-9
Carc. 1B
HP7 Carcinogenic: waste which induces cancer or increases its incidence.
649-049-00-5
A complex combination of hydrocarbons produced as the residual fraction from distillation of the product from a catalytic reforming process. It consists of predominantly aromatic hydrocarbons having carbon numbers predominantly in the range of C10 through C25 and boiling in the range of approximately 160°C to 400°C (320°F to 725°F). This stream is likely to contain 5 wt. % or more of 4- or 6-membered condensed ring aromatic hydrocarbons.
265-069-3
64741-67-9
Carc. 1B
HP7 Carcinogenic: waste which induces cancer or increases its incidence.
649-048-00-X
A complex combination of hydrocarbons obtained by treating a petroleum stock with hydrogen. It consists predominantly of hydrocarbons having carbon numbers predominantly in the range of C9 through C25 and boiling in the range of approximately 150°C to 400°C (302°F to 752°F).
309-863-0
101316-57-8
Carc. 1B
HP7 Carcinogenic: waste which induces cancer or increases its incidence.
649-047-00-4
A complex combination of hydrocarbons obtained by the treatment and distillation of raw steam-cracked naphtha. It consists predominantly of unsaturated hydrocarbons boiling in the range above approximately 180°C (356°F).
308-733-0
98219-64-8
Carc. 1B
HP7 Carcinogenic: waste which induces cancer or increases its incidence.
649-046-00-9
A complex combination of hydrocarbons, sulfur compounds and metal-containing organic compounds obtained as the residue from refinery fractionation cracking processes. It produces a finished oil with a viscosity above 2cSt. at 100°C.
298-754-0
93821-66-0
Carc. 1B
HP7 Carcinogenic: waste which induces cancer or increases its incidence.
649-045-00-3
A complex combination of hydrocarbons produced by the distillation of products from a catalytic cracking process which has been used as a heat transfer fluid. It consists predominantly of hydrocarbons boiling in the range of approximately 220°C to 450°C (428°F to 842°F). This stream is likely to contain organic sulfur compounds.
295-990-6
92201-59-7
Carc. 1B
HP7 Carcinogenic: waste which induces cancer or increases its incidence.
649-044-00-8
A complex combination of hydrocarbons produced as the residual fraction from the distillation of the products from a catalytic cracking process. It consists predominantly of hydrocarbons having carbon numbers predominantly greater than C11 and boiling above approximately 200°C (392°F).
295-511-0
92061-97-7
Carc. 1B
HP7 Carcinogenic: waste which induces cancer or increases its incidence.
649-043-00-2
A complex combination of hydrocarbons obtained by the distillation of crude petroleum. It consists predominantly of aliphatic, aromatic and cycloaliphatic hydrocarbons having carbon numbers predominantly higher than C25 and boiling above approximately 400°C (752°F).
295-396-7
92045-14-2
Carc. 1B
HP7 Carcinogenic: waste which induces cancer or increases its incidence.
649-042-00-7
A complex residuum from the vacuum distillation of the residuum from atmospheric distillation of crude oil. It consists predominantly of hydrocarbons having carbon numbers predominantly greater than C24 and boiling above approximately 390°C (734°F).
292-658-2
90669-76-4
Carc. 1B
HP7 Carcinogenic: waste which induces cancer or increases its incidence.
649-041-00-1
A complex combination of hydrocarbons obtained during the production of refined petroleum tar by the distillation of steam cracked tar. It consists predominantly of aromatic and other hydrocarbons and organic sulfur compounds.
292-657-7
90669-75-3
Carc. 1B
HP7 Carcinogenic: waste which induces cancer or increases its incidence.
649-040-00-6
A complex combination of hydrocarbons obtained by hydrodesulfurization of heavy coker distillate stocks. It consists predominantly of hydrocarbons having carbon numbers predominantly in the range C18 to C44 and boiling in the range of approximately 304°C to 548°C (579°F to 1018° F). Likely to contain 5% or more of 4- to 6- membered condensed ring aromatic hydrocarbons.
285-555-9
85117-03-9
Carc. 1B
HP7 Carcinogenic: waste which induces cancer or increases its incidence.
649-039-00-0
A complex combination of hydrocarbons produced by the vacuum distillation of the residuum from atmospheric distillation of crude oil. It consists of hydrocarbons having carbon numbers predominantly in the range of C15 through C50 and boiling in the range of approximately 270°C to 600°C (518°F to 1112°F). This stream is likely to contain 5 wt.% or more of 4- to 6-membered condensed ring aromatic hydrocarbons.
274-685-1
70592-78-8
Carc. 1B
HP7 Carcinogenic: waste which induces cancer or increases its incidence.
649-038-00-5
A complex combination of hydrocarbons produced by the vacuum distillation of the residuum from atmospheric distillation of crude oil. It consists of hydrocarbons having carbon numbers predominantly in the range of C11 through C35 and boiling in the range of approximately 250°C to 545°C (482°F to 1013°F).
274-684-6
70592-77-7
Carc. 1B
HP7 Carcinogenic: waste which induces cancer or increases its incidence.
649-037-00-X
A complex combination of hydrocarbons produced by the vacuum distillation of the residuum from atmospheric distillation of crude oil. It consists of hydrocarbons having carbon numbers predominantly in the range of C14 through C42 and boiling in the range of approximately 250°C to 545°C (482°F to 1013°F). This stream is likely to contain 5 wt.% or more of 4- to 6-membered condensed ring aromatic hydrocarbons.
274-683-0
70592-76-6
Carc. 1B
HP7 Carcinogenic: waste which induces cancer or increases its incidence.
649-036-00-4
A complex residuum from the distillation of steam-cracked petroleum residues.
273-272-3
68955-36-2
Carc. 1B
HP7 Carcinogenic: waste which induces cancer or increases its incidence.
649-035-00-9
A complex combination of hydrocarbons produced by the vacuum distillation of the residuum from the atmospheric distillation of crude oil.
273-263-4
68955-27-1
Carc. 1B
HP7 Carcinogenic: waste which induces cancer or increases its incidence.
649-034-00-3
A very complex combination of hydrocarbons produced as the residual fraction from the distillation of vacuum residuum and the products from a thermal cracking process. It consists predominantly of hydrocarbons having carbon numbers predominantly greater than C20 and boiling above approximately 350°C (662°F). This stream is likely to contain 5 wt. % or more of 4- to 6-membered condensed ring aromatic hydrocarbons.
272-187-9
68783-13-1
Carc. 1B
HP7 Carcinogenic: waste which induces cancer or increases its incidence.
649-033-00-8
A complex combination of hydrocarbons obtained by the distillation of crude oil. It consists of hydrocarbons having carbon numbers predominantly in the range of C7 through C35 and boiling in the range of approximately 121°C to 510°C (250°F to 950°F).
272-184-2
68783-08-4
Carc. 1B
HP7 Carcinogenic: waste which induces cancer or increases its incidence.
649-032-00-2
A low-sulfur complex combination of hydrocarbons produced as the residual fraction from the topping plant distillation of crude oil. It is the residuum after the straight-run gasoline cut, kerosene cut and gas oil cut have been removed.
271-763-7
68607-30-7
Carc. 1B
HP7 Carcinogenic: waste which induces cancer or increases its incidence.
649-031-00-7
A distillate oil having a minimum viscosity of 900 SUS at 37.7°C (100°F) to a maximum of 9000 SUS at 37.7°C (100°F).
271-384-7
68553-00-4
Carc. 1B
HP7 Carcinogenic: waste which induces cancer or increases its incidence.
649-030-00-1
A complex residuum from the distillation of the products from a steam-cracking process. It consists predominantly of aromatic and unsaturated hydrocarbons having carbon numbers greater than C7 and boiling in the range of approximately 101°C to 555°C (214°F to 1030°F).
271-013-9
68513-69-9
Carc. 1B
HP7 Carcinogenic: waste which induces cancer or increases its incidence.
649-029-00-6
A complex residuum from the vacuum distillation of the residuum from the atmospheric distillation of crude oil. It consists of hydrocarbons having carbon numbers predominantly greater than C13 and boiling above approximately 230°C (446°F).
270-984-6
68512-62-9
Carc. 1B
HP7 Carcinogenic: waste which induces cancer or increases its incidence.
649-028-00-0
A complex combination of hydrocarbons produced as the residual fraction from the distillation of heavy coker gas oil and light vacuum gas oil. It consists predominantly of hydrocarbons having carbon numbers predominantly greater than C13 and boiling above approximately 230°C(446°F).
270-983-0
68512-61-8
Carc. 1B
HP7 Carcinogenic: waste which induces cancer or increases its incidence.
649-027-00-5
A complex combination of hydrocarbons produced as the residual fraction from the distillation of heavy coker gas oil and vacuum gas oil. It predominantly consists of hydrocarbons having carbon numbers predominantly greater than C13 and boiling above approximately 230°C (446°F).
270-796-4
68478-17-1
Carc. 1B
HP7 Carcinogenic: waste which induces cancer or increases its incidence.
649-026-00-X
A complex residuum from the distillation of catalytic reformer fractionator residue. It boils approximately above 399°C (750°F).
270-792-2
68478-13-7
Carc. 1B
HP7 Carcinogenic: waste which induces cancer or increases its incidence.
649-025-00-4
The liquid product from various refinery streams, usually residues. The composition is complex and varies with the source of the crude oil.
270-675-6
68476-33-5
Carc. 1B
HP7 Carcinogenic: waste which induces cancer or increases its incidence.
649-024-00-9
270-674-0
68476-32-4
Carc. 1B
HP7 Carcinogenic: waste which induces cancer or increases its incidence.
649-023-00-3
A complex combination of hydrocarbons obtained by treatment of heavy catalytic cracked distillates with hydrogen to convert organic sulfur to hydrogen sulfide which is removed. It consists of hydrocarbons having carbon numbers predominantly in the range of C15 through C35 and boiling in the range of approximately 260°C to 500°C (500°F to 932°F). This stream is likely to contain 5 wt. % or more of 4- to 6-membered condensed ring aromatic hydrocarbons.
269-784-1
68333-28-8
Carc. 1B
HP7 Carcinogenic: waste which induces cancer or increases its incidence.
649-022-00-8
A complex combination of hydrocarbons obtained by treating intermediate catalytic cracked distillates with hydrogen to convert organic sulfur to hydrogen sulfide which is removed. It consists of hydrocarbons having carbon numbers predominantly in the range of C11 through C30 and boiling in the range of approximately 205°C to 450°C (401°F to 842°F). It contains a relatively large proportion of tricyclic aromatic hydrocarbons.
269-783-6
68333-27-7
Carc. 1B
HP7 Carcinogenic: waste which induces cancer or increases its incidence.
649-021-00-2
A complex combination of hydrocarbons obtained by treating catalytic cracked clarified oil with hydrogen to convert organic sulfur to hydrogen sulfide which is removed. It consists of hydrocarbons having carbon numbers predominantly greater than C20 and boiling above approximately 350°C (662°F). This stream is likely to contain 5 wt. % or more of 4- to 6-membered condensed ring aromatic hydrocarbons.
269-782-0
68333-26-6
Carc. 1B
HP7 Carcinogenic: waste which induces cancer or increases its incidence.
649-020-00-7
A complex residuum from atmospheric distillation of crude oil. It consists of hydrocarbons having carbon numbers predominantly greater than C11 and boiling above approximately 200°C (392°F). This stream is likely to contain 5 wt.% or more of 4- to 6-membered condensed ring aromatic hydrocarbons.
269-777-3
68333-22-2
Carc. 1B
HP7 Carcinogenic: waste which induces cancer or increases its incidence.
649-019-00-1
A complex combination of hydrocarbons obtained as the residual fraction from the distillation of the products of a steam cracking process (including steam cracking to produce ethylene). It consists predominantly of unsaturated hydrocarbons having carbon numbers predominantly greater than C14 and boiling above approximately 260°C (500°F). This stream is likely to contain 5 wt. % or more of 4- to 6-membered condensed ring aromatic hydrocarbons.
265-193-8
64742-90-1
Carc. 1B
HP7 Carcinogenic: waste which induces cancer or increases its incidence.
649-018-00-6
A complex combination of hydrocarbons obtained from a catalytic hydrodesulfurization process. It consists of hydrocarbons having carbon numbers predominantly in the range of C20 through C50 and boiling in the range of approximately 350°C to 600°C (662°F to 1112°F). This stream is likely to contain 5 wt. % or more of 4- to 6-membered condensed ring aromatic hydrocarbons.
265-189-6
64742-86-5
Carc. 1B
HP7 Carcinogenic: waste which induces cancer or increases its incidence.
649-017-00-0
A complex combination of hydrocarbons obtained by treating an atmospheric tower residuum with hydrogen in the presence of a catalyst under conditions primarily to remove organic sulfur compounds. It consists of hydrocarbons having carbon numbers predominantly greater than C20 and boiling above approximately 350°C (662°F). This stream is likely to contain 5 wt. % or more of 4- to 6-membered condensed ring aromatic hydrocarbons.
265-181-2
64742-78-5
Carc. 1B
HP7 Carcinogenic: waste which induces cancer or increases its incidence.
649-016-00-5
A complex combination of hydrocarbons obtained by treating a petroleum fraction with hydrogen in the presence of a catalyst. It consists of hydrocarbons having carbon numbers predominantly in the range of C13 through C50 and boiling in the range of approximately 230°C to 600°C (446°F to 1112°F). This stream is likely to contain 5 wt. % or more of 4- to 6- membered condensed ring aromatic hydrocarbons.
265-162-9
64742-59-2
Carc. 1B
HP7 Carcinogenic: waste which induces cancer or increases its incidence.
649-015-00-X
A complex combination of hydrocarbons from the distillation of the products from a thermal cracking process. It consists predominantly of unsaturated hydrocarbons having carbon numbers predominantly in the range of C15 through C36 and boiling in the range of approximately 260°C to 480°C (500°F to 896°F). This stream is likely to contain 5 wt. % or more of 4- to 6-membered condensed ring aromatic hydrocarbons.
265-082-4
64741-81-7
Carc. 1B
HP7 Carcinogenic: waste which induces cancer or increases its incidence.
649-014-00-4
A complex combination of hydrocarbons produced as the residual fraction from distillation of the product from a thermal cracking process. It consists predominantly of unsaturated hydrocarbons having carbon numbers predominantly greater than C20 and boiling above approximately 350°C (662°F). This stream is likely to contain 5 wt. % or more of 4- to 6-membered condensed ring aromatic hydrocarbons.
265-081-9
64741-80-6
Carc. 1B
HP7 Carcinogenic: waste which induces cancer or increases its incidence.
649-013-00-9
A complex combination of hydrocarbons produced as the residual fraction from distillation of the products of a hydrocracking process. It consists of hydrocarbons having carbon numbers predominantly greater than C20 and boiling above approximately 350°C (662°F).
265-076-1
64741-75-9
Carc. 1B
HP7 Carcinogenic: waste which induces cancer or increases its incidence.
649-012-00-3
A complex combination of hydrocarbons produced as the residual fraction from distillation of the products from a catalytic cracking process. It consists of hydrocarbons having carbon numbers predominantly greater than C20 and boiling above approximately 350°C (662°F). This stream is likely to contain 5 wt. % or more of 4- to 6-membered condensed ring aromatic hydrocarbons.
265-064-6
64741-62-4
Carc. 1B
HP7 Carcinogenic: waste which induces cancer or increases its incidence.
649-011-00-8
A complex combination of hydrocarbons produced by the distillation of products from a catalytic cracking process. It consists of hydrocarbons having carbon numbers predominantly in the range of C15 through C35 and boiling in the range of approximately 260°C to 500°C (500°F to 932°F). This stream is likely to contain 5 wt. % or more of 4- to 6-membered condensed ring aromatic hydrocarbons.
265-063-0
64741-61-3
Carc. 1B
HP7 Carcinogenic: waste which induces cancer or increases its incidence.
649-010-00-2
A complex combination of hydrocarbons produced by the vacuum distillation of the residuum from atmospheric distillation of crude oil. It consists of hydrocarbons having carbon numbers predominantly in the range of C20 through C50 and boiling in the range of approximately 350°C to 600°C (662°F to 1112°F). This stream is likely to contain 5 wt. % or more of 4- to 6-membered condensed ring aromatic hydrocarbons.
265-058-3
64741-57-7
Carc. 1B
HP7 Carcinogenic: waste which induces cancer or increases its incidence.
649-009-00-7
A complex residuum from the atmospheric distillation of crude oil. It consists of hydrocarbons having carbon numbers predominantly greater than C20 and boiling above approximately 350°C (662°F). This stream is likely to contain 5 wt. % or more of 4- to 6-membered condensed ring aromatic hydrocarbons.
265-045-2
64741-45-3
Carc. 1B
HP7 Carcinogenic: waste which induces cancer or increases its incidence.
649-008-00-1
400-160-5
91770-03-5
Skin Irrit. 2
Aquatic Chronic 2
HP4 Irritant — skin irritation and eye damage: waste which on application can cause skin irritation or damage to the eye.
HP14 Ecotoxic: waste which presents or may present immediate or delayed risks for one or more sectors of the environment.
649-007-00-6
A complex combination of hydrocarbons obtained by solvent extraction from a naphthenic distillate having a viscosity of 27cSt at 100°C (212°F). It consists predominantly of aromatic hydrocarbons having carbon numbers predominantly in the range of C26 through C55 and boiling in the range of approximately 395°C to 640°C (743°F to 1184°F).
307-753-7
97722-04-8
Carc. 1B
HP7 Carcinogenic: waste which induces cancer or increases its incidence.
649-006-00-0
A complex combination of hydrocarbons obtained by solvent extraction from light vacuum petroleum gas oil. It consists predominantly of aromatic hydrocarbons having carbon numbers predominantly in the range of C13 through C30.
295-341-7
91995-78-7
Carc. 1B
HP7 Carcinogenic: waste which induces cancer or increases its incidence.
649-005-00-5
A complex combination of hydrocarbons obtained as the extract from a solvent extraction process. It consists predominantly of aromatic hydrocarbons having carbon numbers predominantly in the range of C20 through C50. This stream is likely to contain 5 wt. % or more of 4- to 6-membered condensed ring aromatic hydrocarbons.
265-111-0
64742-11-6
Carc. 1B
HP7 Carcinogenic: waste which induces cancer or increases its incidence.
649-004-00-X
A complex combination of hydrocarbons obtained as the extract from a solvent extraction process. It consists predominantly of aromatic hydrocarbons having carbon numbers predominantly in the range of C15 through C30. This stream is likely to contain 5 wt. % or more of 4- to 6-membered condensed ring aromatic hydrocarbons.
265-104-2
64742-05-8
Carc. 1B
HP7 Carcinogenic: waste which induces cancer or increases its incidence.
649-003-00-4
A complex combination of hydrocarbons obtained as the extract from a solvent extraction process. It consists predominantly of aromatic hydrocarbons having carbon numbers predominantly in the range of C20 through C50. This stream is likely to contain 5 wt. % or more of 4- to 6-membered condensed ring aromatic hydrocarbons.
265-103-7
64742-04-7
Carc. 1B
HP7 Carcinogenic: waste which induces cancer or increases its incidence.
649-002-00-9
A complex combination of hydrocarbons obtained as the extract from a solvent extraction process. It consists predominantly of aromatic hydrocarbons having carbon numbers predominantly in the range of C15 through C30. This stream is likely to contain 5 wt. % or more of 4- to 6-membered condensed ring aromatic hydrocarbons.
265-102-1
64742-03-6
Carc. 1B
HP7 Carcinogenic: waste which induces cancer or increases its incidence.
649-001-00-3
The volatile organic liquid condensed from the gas evolved in the low-temperature (less than 700°C (1292°F)) destructive distillation of coal. Composed primarily of C6-10 hydrocarbons.
292-635-7
90641-11-5
Carc. 1B
Muta. 1B
HP7 Carcinogenic: waste which induces cancer or increases its incidence.
HP11 Mutagenic: waste which may cause a mutation, that is a permanent change in the amount or structure of the genetic material in a cell.
648-156-00-4
Diesel engine fuel produced by the hydrogenation of the middle distillate fraction of the products of hydrocracking of coal extract or solution produced by the liquid solvent extraction or supercritical gas extraction processes and boiling in the range of approximately 200°C to 280°C (392°F to 536°F). Composed primarily of hydrogenated two-ring hydrocarbons and their alkyl derivatives having carbon numbers predominantly in the range of C11 through C14.
302-695-9
94114-59-7
Carc. 2
HP7 Carcinogenic: waste which induces cancer or increases its incidence.
648-155-00-9
Jet engine fuel produced by hydrogenation of the middle distillate fraction of the products of hydrocracking of coal extract or solution produced by the liquid solvent extraction or supercritical gas extraction processes and boiling in the range of approximately 180°C to 225°C (356°F to 473°F). Composed primarily of hydrogenated two-ring hydrocarbons and their alkyl derivatives having carbon numbers predominantly in the range of C10 through C12.
302-694-3
94114-58-6
Carc. 2
HP7 Carcinogenic: waste which induces cancer or increases its incidence.
648-154-00-3
Distillate from the hydrogenation of hydrocracked middle distillate from coal extract or solution produced by the liquid solvent extraction or supercritical gas extraction processes and boiling in the range of approximately 180°C to 280°C (356°F to 536°F). Composed primarily of hydrogenated two- ring carbon compounds and their alkyl derivatives having carbon numbers predominantly in the range of C9 through C14.
302-693-8
94114-57-5
Carc. 1B
Muta. 1B
HP7 Carcinogenic: waste which induces cancer or increases its incidence.
HP11 Mutagenic: waste which may cause a mutation, that is a permanent change in the amount or structure of the genetic material in a cell.
648-153-00-8
Distillate obtained from the hydrocracking of coal extract or solution produced by the liquid solvent extraction or supercritical gas extraction processes and boiling in the range of approximately 180°C to 300°C (356°F to 572°F. Composed primarily of two-ring aromatic, hydrogenated aromatic and naphthenic compounds, their alkyl derivatives and alkanes having carbon numbers predominantly in the range of C9 through C14. Nitrogen, sulfur and oxygen-containing compounds are also present.
302-692-2
94114-56-4
Carc. 1B
Muta. 1B
HP7 Carcinogenic: waste which induces cancer or increases its incidence.
HP11 Mutagenic: waste which may cause a mutation, that is a permanent change in the amount or structure of the genetic material in a cell.
648-152-00-2
Motor fuel produced by the reforming of the refined naphtha fraction of the products of hydrocracking of coal extract or solution produced by the liquid solvent extraction or supercritical gas extraction processes and boiling in the range of approximately 30°C to 180°C (86°F to 356°F). Composed primarily of aromatic and naphthenic hydrocarbons, their alkyl derivatives and alkyl hydrocarbons having carbon numbers in the range of C4 through C9.
302-691-7
94114-55-3
Carc. 1B
HP7 Carcinogenic: waste which induces cancer or increases its incidence.
648-151-00-7
Fraction of the distillate obtained by hydrocracking of coal extract or solution produced by the liquid solvent extraction or supercritical gas extraction processes and boiling in the range of approximately 30°C to 180°C (86°F to 356°F). Composed primarily of aromatic, hydrogenated aromatic and naphthenic compounds, their alkyl derivatives and alkanes with carbon numbers predominantly in the range of C4 to C9. Nitrogen, sulfur and oxygen-containing aromatic and hydrogenated aromatic compounds are also present.
302-690-1
94114-54-2
Carc. 1B
Muta. 1B
HP7 Carcinogenic: waste which induces cancer or increases its incidence.
HP11 Mutagenic: waste which may cause a mutation, that is a permanent change in the amount or structure of the genetic material in a cell.
648-150-00-1
Distillate obtained by hydrocracking of coal extract or solution produced by the liquid solvent extraction or supercritical gas extraction processes and boiling in the range of approximately 30°C to 300°C (86°F to 572°F). Composed primarily of aromatic, hydrogenated aromatic and naphthenic compounds, their alkyl derivatives and alkanes with carbon numbers predominantly in the range of C4 through C14. Nitrogen, sulfur and oxygen-containing aromatic and hydrogenated aromatic compounds are also present.
302-689-6
94114-53-1
Carc. 1B
Muta. 1B
HP7 Carcinogenic: waste which induces cancer or increases its incidence.
HP11 Mutagenic: waste which may cause a mutation, that is a permanent change in the amount or structure of the genetic material in a cell.
648-149-00-6
The liquid product of condensation of vapors emitted during the digestion of coal in a liquid solvent and boiling in the range of approximately 30°C to 300°C (86°F to 572°F). Composed primarily of partly hydrogenated condensed-ring aromatic hydrocarbons, aromatic compounds containing nitrogen, oxygen and sulfur, and their alkyl derivatives having carbon numbers predominantly in the range of C4 through C14.
302-688-0
94114-52-0
Carc. 1B
Muta. 1B
HP7 Carcinogenic: waste which induces cancer or increases its incidence.
HP11 Mutagenic: waste which may cause a mutation, that is a permanent change in the amount or structure of the genetic material in a cell.
648-148-00-0

Export search results to: