Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Physical & Chemical properties

Flash point

Currently viewing:

Administrative data

Link to relevant study record(s)

Referenceopen allclose all

Endpoint:
flash point
Type of information:
experimental study
Adequacy of study:
supporting study
Study period:
09 Mar 2012
Reliability:
2 (reliable with restrictions)
Rationale for reliability incl. deficiencies:
other: Certificate of Analysis
Qualifier:
according to guideline
Guideline:
other: ASTM D92
GLP compliance:
no
Type of method:
open cup
Remarks:
Cleveland Open Cup
Flash point:
120 °C
Atm. press.:
ca. 1 013 hPa

Pressure was not reported. Data is estimated, because the test was conducted under ambient condition using an open cup system.

Endpoint:
flash point
Type of information:
experimental study
Adequacy of study:
key study
Study period:
09 Mar 2012
Reliability:
2 (reliable with restrictions)
Rationale for reliability incl. deficiencies:
other: Certificate of Analysis
Qualifier:
according to guideline
Guideline:
ASTM D93 (Standard test methods for flash point by pensky-martens closed cup tester)
GLP compliance:
no
Type of method:
equilibrium method closed cup
Remarks:
Pensky-Martens Closed Cup
Flash point:
128.5 °C
Atm. press.:
998 hPa

Description of key information

128.5 °C at 998 hPa (closed cup, ASTM D93)

Key value for chemical safety assessment

Additional information

A second flash point determined with an open cup method of 120 °C is supporting.