Administrative data

Endpoint:
explosive properties of explosives
Type of information:
experimental study
Adequacy of study:
key study
Study period:
The study was conducted between 06 July 2007 and 17 August 2007.
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
2007
Report date:
2007

Materials and methods

Test guideline
Qualifier:
according to guideline
Guideline:
EU Method A.14 (Explosive properties)
Deviations:
no
GLP compliance:
yes (incl. QA statement)

Test material

Constituent 1
Reference substance name:
Magenta T-43
IUPAC Name:
Magenta T-43
Test material form:
solid: particulate/powder
Details on test material:
Sponsor's identification: MAGENTA T-43
Description: dark red solid
Storage conditions: room temperature in the dark
Batch number: H186-5

Results and discussion

Results of test series for explosivesopen allclose all
Test series:
other: Not specified
Method:
UN Test 3 (a) (ii): BAM Fallhammer
Parameter:
other: Not specified
Result:
negative, no explosion
Remarks on result:
other: No signs of ignition or explosion on impact. Signs of decomposition observed.
Test series:
other: Not specified
Method:
UN Test 3 (b) (i): BAM friction apparatus
Parameter:
other: Not specified
Result:
negative, no explosion
Remarks on result:
other: No signs of ignition or explosion. Marks indication decomposition were observed.
Test series:
other: Not specified
Method:
other: Koenen steel tube test
Parameter:
other: Not specified
Result:
other: The tube was recovered intact.
Remarks on result:
other: Orange flame from the orifice, test material ajected and a dome of test material formed over the orifice.

Any other information on results incl. tables

Results

 

Bam fall hammer test

 

Test

Observations

1

There were no signs of ignition or explosion on impact. When the test assembly was dismantled there were signs of decomposition the sample had turned brown.

2

There were no signs of ignition or explosion on impact. When the test assembly was dismantled there were signs of decomposition the sample had turned brown.

3

There were no signs of ignition or explosion on impact. When the test assembly was dismantled there were signs of decomposition the sample had turned brown.

4

There were no signs of ignition or explosion on impact. When the test assembly was dismantled there were signs of decomposition the sample had turned brown.

5

There were no signs of ignition or explosion on impact. When the test assembly was dismantled there were signs of decomposition the sample had turned brown.

6

There were no signs of ignition or explosion on impact. When the test assembly was dismantled there were signs of decomposition the sample had turned brown.

 

Result: Negative

 

Bam friction Test

Test

Observations

1

There were no signs of ignition or explosion. A grey mark on the porcelain plate and

peg indicated decomposition.

2

There were no signs of ignition or explosion. A grey mark on the porcelain plate and

peg indicated decomposition.

3

There were no signs of ignition or explosion. A grey mark on the porcelain plate and

peg indicated decomposition.

4

There were no signs of ignition or explosion. A grey mark on the porcelain plate and

peg indicated decomposition.

5

There were no signs of ignition or explosion. A grey mark on the porcelain plate and

peg indicated decomposition.

6

There were no signs of ignition or explosion. A grey mark on the porcelain plate and

peg indicated decomposition.

 

Result: Negative

 

 

Koenen Steel tube test

6 mm Orifice Plate

Test

Time (s)

Observations

1

23

An orange flame from the orifice

69

Test material was ejected from the orifice

122

A dome of charred test material formed over the orifice.

300

The test was stopped. The orange flame remained. The tube was recovered

intact.

2

23

An orange flame from the orifice

46

Test material was ejected from the orifice

160

A dome of charred test material formed over the orifice.

300

The test was stopped. The orange flame self-extinguished. The tube was

recovered intact.

3

25

An orange flame from the orifice.

40

Test material was ejected from the orifice.

138

A dome of charred test material formed over the orifice

300

The test was stopped. The orange flame remained. The tube was recovered

intact.

 

2 mm Orifice Plate

Test

Time (s)

Observations

1

26

An orange flame from the orifice

59

Burning test material was ejected from the orifice.

129

A dome of charred test material formed over the orifice.

300

The test was stopped. The self-extinguished. The tube was recovered

intact.

2

24

An orange flame from the orifice

46

Test material was ejected from the orifice

155

A dome of charred test material formed over the orifice.

300

The test was stopped. The flame self-extinguished. The tube was

recovered intact.

3

25

An orange flame from the orifice.

46

Test material was ejected from the orifice.

140

A dome of charred test material formed over the orifice

300

The test was stopped. The orange flame self-extinguished. The tube was recovered

intact.

 

Result: Negative

Applicant's summary and conclusion

Interpretation of results:
other: Not classified according to EU criteria.
Conclusions:
The test material has been determined not to have explosive properties.
Executive summary: