Registration Dossier
Registration Dossier
Data platform availability banner - registered substances factsheets
Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.
The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.
Diss Factsheets
Use of this information is subject to copyright laws and may require the permission of the owner of the information, as described in the ECHA Legal Notice.
EC number: 231-403-1 | CAS number: 7534-94-3
- Life Cycle description
- Uses advised against
- Endpoint summary
- Appearance / physical state / colour
- Melting point / freezing point
- Boiling point
- Density
- Particle size distribution (Granulometry)
- Vapour pressure
- Partition coefficient
- Water solubility
- Solubility in organic solvents / fat solubility
- Surface tension
- Flash point
- Auto flammability
- Flammability
- Explosiveness
- Oxidising properties
- Oxidation reduction potential
- Stability in organic solvents and identity of relevant degradation products
- Storage stability and reactivity towards container material
- Stability: thermal, sunlight, metals
- pH
- Dissociation constant
- Viscosity
- Additional physico-chemical information
- Additional physico-chemical properties of nanomaterials
- Nanomaterial agglomeration / aggregation
- Nanomaterial crystalline phase
- Nanomaterial crystallite and grain size
- Nanomaterial aspect ratio / shape
- Nanomaterial specific surface area
- Nanomaterial Zeta potential
- Nanomaterial surface chemistry
- Nanomaterial dustiness
- Nanomaterial porosity
- Nanomaterial pour density
- Nanomaterial photocatalytic activity
- Nanomaterial radical formation potential
- Nanomaterial catalytic activity
- Endpoint summary
- Stability
- Biodegradation
- Bioaccumulation
- Transport and distribution
- Environmental data
- Additional information on environmental fate and behaviour
- Ecotoxicological Summary
- Aquatic toxicity
- Endpoint summary
- Short-term toxicity to fish
- Long-term toxicity to fish
- Short-term toxicity to aquatic invertebrates
- Long-term toxicity to aquatic invertebrates
- Toxicity to aquatic algae and cyanobacteria
- Toxicity to aquatic plants other than algae
- Toxicity to microorganisms
- Endocrine disrupter testing in aquatic vertebrates – in vivo
- Toxicity to other aquatic organisms
- Sediment toxicity
- Terrestrial toxicity
- Biological effects monitoring
- Biotransformation and kinetics
- Additional ecotoxological information
- Toxicological Summary
- Toxicokinetics, metabolism and distribution
- Acute Toxicity
- Irritation / corrosion
- Sensitisation
- Repeated dose toxicity
- Genetic toxicity
- Carcinogenicity
- Toxicity to reproduction
- Specific investigations
- Exposure related observations in humans
- Toxic effects on livestock and pets
- Additional toxicological data
Adsorption / desorption
Administrative data
- Endpoint:
- adsorption / desorption: screening
- Type of information:
- experimental study
- Adequacy of study:
- key study
- Study period:
- 2017-05-23
- Reliability:
- 1 (reliable without restriction)
- Rationale for reliability incl. deficiencies:
- guideline study
Data source
Reference
- Reference Type:
- study report
- Title:
- Unnamed
- Year:
- 2 007
- Report date:
- 2017
Materials and methods
Test guideline
- Qualifier:
- according to guideline
- Guideline:
- OECD Guideline 121 (Estimation of the Adsorption Coefficient (Koc) on Soil and on Sewage Sludge using High Performance Liquid Chromatography (HPLC))
- Deviations:
- no
- GLP compliance:
- yes (incl. QA statement)
- Type of method:
- HPLC estimation method
Test material
- Reference substance name:
- Exo-1,7,7-trimethylbicyclo[2.2.1]hept-2-yl methacrylate
- EC Number:
- 231-403-1
- EC Name:
- Exo-1,7,7-trimethylbicyclo[2.2.1]hept-2-yl methacrylate
- Cas Number:
- 7534-94-3
- Molecular formula:
- C14H22O2
- IUPAC Name:
- 1,7,7-trimethylbicyclo[2.2.1]hept-2-yl methacrylate
- Test material form:
- liquid
Constituent 1
- Specific details on test material used for the study:
- - Name of test material (as cited in study report): IBOMA Isobornyl methacrylate
- Physical state: Clear colourless liquid
- Storage conditions: Ambient temperature (10 °C to 30°C), protected from light
- Expiry date: November 04, 2017 - Radiolabelling:
- no
Study design
HPLC method
- Details on study design: HPLC method:
- HPLC equipment: HPLC System Agilent 1100 series: H PLC pump G 1311 A, autosampler
G1313A, column oven G1316A, degasser G1322A, variable wavelength detector C,1314A
Column: Stationary phase: Zorbax Eclipse XDB-CN, Agilent Particle size: 5 μm, pore size: 80 A, Material: stainless steel, dimensions: 150 mm x 4.6 mm, Serial No.: USBJ002539, Column temperature: 25 °C
Mobile phase (eluent): Methanol/ demineralized water 55:45 % (v/v), pH = 5.8, isocratic elution
Flow rate: 1 ml/min
lnjection volume: 10 μI
Detection: 210 nm (dead time marker), 210 nm (calibration substances), 208 nm (test item)
lnjection amounts:
Dead time marker: 4.62 μg
Calibration substances:0. 73 - 1.16 μg
Testitem: 0.38 μg
The test item was dissolved in methanol and diluted from 0.1 ml to 1 ml with eluent. The dead time marker and the calibration substances were dissolved in methanol and diluted from 0.1 ml to 1.0 ml with eluent.
Batch equilibrium or other method
- Analytical monitoring:
- yes
Results and discussion
Adsorption coefficient
- Key result
- Type:
- log Koc
- Value:
- 3.71 dimensionless
- Temp.:
- 25 °C
- Remarks on result:
- other: HPLC-Merthod
Any other information on results incl. tables
Determination of the dead timet0
Dead time marker |
tR/min 1 st Measurement |
tR/ min 2 nd Measurement |
tR/min Mean |
Formamide |
1.708 |
1.708 |
1.708 |
Dead time to = 1.71
Calibration data-1stmeasurement
Calibration substance |
1st lnj. tR/min |
k |
log |
logKoca |
Acetanilide |
2.168 |
0.27 |
-0.57 |
1.25 |
Atrazin |
2.603 |
0.52 |
-0.28 |
1.81 |
Triadimenol |
3.568 |
1.09 |
0.04 |
2.40 |
Linuron |
4.115 |
1.41 |
0.15 |
2.59 |
Pyrazophos |
7.325 |
3.29 |
0.52 |
3.65 |
Diclofop-methyl |
10.279 |
5.02 |
0.70 |
4.20 |
4,4' DDT |
34.548 |
19.23 |
1.28 |
5.63 |
|
|
|
|
|
Regression:1ogK0c=a+b·logk
Parameters:
a 2.444
b = 2.408
r2= 0.9919
logK0c ofthe test item-1stmeasurement
Testltem |
1st lnj. tR/min |
k |
log |
logKoca |
Isobornyl methacylate |
7.567 |
3.43 |
0.54 |
3.73 |
Calibration data-2 ndmeasurement
Calibration substance |
1st lnj. tR/min |
k |
log |
logKoca |
Acetanilide |
2.174 |
0.27 |
-0.56 |
1.25 |
Atrazin |
2.609 |
0.53 |
-0.28 |
1.81 |
Triadimenol |
3.566 |
1.09 |
0.04 |
2.40 |
Linuron |
4.135 |
1.42 |
0.15 |
2.59 |
Pyrazophos |
7.338 |
3.30 |
0.52 |
3.65 |
Diclofop-methyl |
10.427 |
5.10 |
0.71 |
4.20 |
4,4' DDT |
35.638 |
19.87 |
1.30 |
5.63 |
|
|
|
|
|
Regression:1ogK0c=a+b·log k
Parameters:
a =2.435
b = 2.397
r2= 0.9926
logK0c ofthe test item-2 ndmeasurement
Testltem |
1st lnj. tR/min |
k |
log |
logKoca |
Isobornyl methacylate |
7.510 |
3.40 |
0.53 |
3.71 |
Result: mean adsorption coefficient logKoc of 3.7.
Applicant's summary and conclusion
- Validity criteria fulfilled:
- yes
- Conclusions:
- Log Koc of Isobornyl methacrylate was measuerd in OECD 121 Guideline , HPLC Method. Result. Log Koc=3.71
- Executive summary:
Log Koc of Isobornyl methacrylate was measured in OECD 121 Guideline test, HPLC Method. Result. Log Koc=3.71
NOTE: Any of data in this dataset are disseminated by the European Union on a right-to-know basis and this is not a publication in the same sense as a book or an article in a journal. The right of ownership in any part of this information is reserved by the data owner(s). The use of this information for any other, e.g. commercial purpose is strictly reserved to the data owners and those persons or legal entities having paid the respective access fee for the intended purpose.
Information on Registered Substances comes from registration dossiers which have been assigned a registration number. The assignment of a registration number does however not guarantee that the information in the dossier is correct or that the dossier is compliant with Regulation (EC) No 1907/2006 (the REACH Regulation). This information has not been reviewed or verified by the Agency or any other authority. The content is subject to change without prior notice.
Reproduction or further distribution of this information may be subject to copyright protection. Use of the information without obtaining the permission from the owner(s) of the respective information might violate the rights of the owner.