Registration Dossier

Diss Factsheets

Environmental fate & pathways

Biodegradation in water: screening tests

Currently viewing:

Administrative data

Endpoint:
biodegradation in water: ready biodegradability
Type of information:
experimental study
Adequacy of study:
key study

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
1999
Report date:
1999

Materials and methods

Test guidelineopen allclose all
Qualifier:
according to guideline
Guideline:
OECD Guideline 301 F (Ready Biodegradability: Manometric Respirometry Test)
Deviations:
no
Qualifier:
according to guideline
Guideline:
EU Method C.4-D (Determination of the "Ready" Biodegradability - Manometric Respirometry Test)
Deviations:
no

Test material

Study design

Oxygen conditions:
aerobic
Inoculum or test system:
activated sludge, domestic, non-adapted
Duration of test (contact time):
28 d
Initial test substance concentration
Initial conc.:
20 - 20.1 mg/L
Based on:
other:

Results and discussion

% Degradationopen allclose all
Parameter:
other:
Value:
26.1
Sampling time:
28 d
Parameter:
other:
Value:
25.3
Sampling time:
28 d

Applicant's summary and conclusion

Validity criteria fulfilled:
yes