Registration Dossier
Registration Dossier
Diss Factsheets
Use of this information is subject to copyright laws and may require the permission of the owner of the information, as described in the ECHA Legal Notice.
EC number: 213-147-2 | CAS number: 927-07-1
- Life Cycle description
- Uses advised against
- Endpoint summary
- Appearance / physical state / colour
- Melting point / freezing point
- Boiling point
- Density
- Particle size distribution (Granulometry)
- Vapour pressure
- Partition coefficient
- Water solubility
- Solubility in organic solvents / fat solubility
- Surface tension
- Flash point
- Auto flammability
- Flammability
- Explosiveness
- Oxidising properties
- Oxidation reduction potential
- Stability in organic solvents and identity of relevant degradation products
- Storage stability and reactivity towards container material
- Stability: thermal, sunlight, metals
- pH
- Dissociation constant
- Viscosity
- Additional physico-chemical information
- Additional physico-chemical properties of nanomaterials
- Nanomaterial agglomeration / aggregation
- Nanomaterial crystalline phase
- Nanomaterial crystallite and grain size
- Nanomaterial aspect ratio / shape
- Nanomaterial specific surface area
- Nanomaterial Zeta potential
- Nanomaterial surface chemistry
- Nanomaterial dustiness
- Nanomaterial porosity
- Nanomaterial pour density
- Nanomaterial photocatalytic activity
- Nanomaterial radical formation potential
- Nanomaterial catalytic activity
- Endpoint summary
- Stability
- Biodegradation
- Bioaccumulation
- Transport and distribution
- Environmental data
- Additional information on environmental fate and behaviour
- Ecotoxicological Summary
- Aquatic toxicity
- Endpoint summary
- Short-term toxicity to fish
- Long-term toxicity to fish
- Short-term toxicity to aquatic invertebrates
- Long-term toxicity to aquatic invertebrates
- Toxicity to aquatic algae and cyanobacteria
- Toxicity to aquatic plants other than algae
- Toxicity to microorganisms
- Endocrine disrupter testing in aquatic vertebrates – in vivo
- Toxicity to other aquatic organisms
- Sediment toxicity
- Terrestrial toxicity
- Biological effects monitoring
- Biotransformation and kinetics
- Additional ecotoxological information
- Toxicological Summary
- Toxicokinetics, metabolism and distribution
- Acute Toxicity
- Irritation / corrosion
- Sensitisation
- Repeated dose toxicity
- Genetic toxicity
- Carcinogenicity
- Toxicity to reproduction
- Specific investigations
- Exposure related observations in humans
- Toxic effects on livestock and pets
- Additional toxicological data

Adsorption / desorption
Administrative data
Link to relevant study record(s)
- Endpoint:
- adsorption / desorption: screening
- Type of information:
- experimental study
- Adequacy of study:
- key study
- Study period:
- 2012-04-17 to 2012-04-17
- Reliability:
- 1 (reliable without restriction)
- Rationale for reliability incl. deficiencies:
- guideline study
- Qualifier:
- according to guideline
- Guideline:
- EU Method C.19 (Estimation of the Adsorption Coefficient (KOC) on Soil and Sewage Sludge Using High Performance Liquid Chromatography (HPLC))
- Version / remarks:
- May 2008
- Deviations:
- no
- Qualifier:
- according to guideline
- Guideline:
- OECD Guideline 121 (Estimation of the Adsorption Coefficient (Koc) on Soil and on Sewage Sludge using High Performance Liquid Chromatography (HPLC))
- Version / remarks:
- January 22, 2001
- Deviations:
- no
- GLP compliance:
- yes (incl. QA statement)
- Type of method:
- HPLC estimation method
- Media:
- soil/sewage sludge
- Radiolabelling:
- no
- Test temperature:
- 25 °C
- Details on study design: HPLC method:
- HPLC Conditions:
- Column: LiChrospher 100 CN (5μm) 250x4, No: 933278
- Mobile Phase: Methanol : Water = 55 : 45 (v/v) (pH value of ultrapure water: 6.4)
- Flow: 1 mL/min
- Injection volume: 10 μL
- Temperature: 25 °C
- Detector: UV 254 nm (Reference Items)
- Detector: UV 200 nm (Test Item)
Reference Items:
Six chemicals (acetanilide, methyl benzoate, isoproturon, linuron, naphthalene, fenthion) for which log Koc has been reported were used to calibrate the elution time in units of log Koc. - Analytical monitoring:
- yes
- Details on sampling:
- Test solutions:
The reference items were dissolved in methanol. The concentrations of the stock solutions were about 1 mg/mL.
These stock solutions were diluted with eluent resulting in concentrations of the test solutions of approximately 10 μg/mL. The sodium nitrate stock solutions was diluted with eluent resulting in concentration of the test solution of approximately 100 μg/mL.
The test item was dissolved in methanol. The concentration of this solution was about 1 mg/mL. It was diluted with eluent to 100 μg/mL. - Details on test conditions:
- Performance of the test
Three series of the above-mentioned reference solutions were measured with two parallel injections, each. Three series of the test item solution were measured with two parallel injections, each. The retention times were determined. The three calibration series and three test item series were measured alternately.
For the determination of t0 (t0 = retention time of the unretarded component) three series of sodium nitrate solution were injected twice. - Type:
- log Koc
- Value:
- 1.59
- Temp.:
- 25 °C
- Key result
- Type:
- Koc
- Value:
- 39
- Temp.:
- 25 °C
- Details on results (HPLC method):
- - Retention times of reference substances used for calibration: acetanilide (3.23 minutes), methyl benzoate (3.68 minutes), isoproturon (3.80 minutes), linuron (4.82 minutes), naphthalene (5.30 minutes), fenthion (7.02 minutes)
- Average retention data for test substance: 3.49 minutes - Validity criteria fulfilled:
- yes
- Conclusions:
- Using the HPLC method the log Koc of tert-butyl peroxypivalate was determined to be 1.59.
- Executive summary:
A study was conducted according to OECD test guideline 121 and Regulation (EC) No 440/2008 method C.19. The purpose of this study was to estimate the adsorption coefficient, Koc of the test item using HPLC method. This method is applicable for substances, which have log Koc value ranging from 1.5 to 5.0. The log Koc was estimated to be 1.59 and the Koc 39.
Reference
Quality criteria were met, as values of log Koc derived from individual measurements fell within a range of 0.25 log units.
The correlation coefficient R for the relationship between log k and log Koc of the test item is 0.990.
The difference of the estimated adsorption coefficient to the value of reference item fell within a range of ± 0.5 log units.
Description of key information
Using the HPLC method the log Koc of tert-butyl peroxypivalate was determined to be 1.59.
Key value for chemical safety assessment
- Koc at 20 °C:
- 39
Additional information
A study was conducted according to OECD test guideline 121 and Regulation (EC) No 440/2008 method C.19. The purpose of this study was to estimate the adsorption coefficient, Koc of the test item using HPLC method. This method is applicable for substances, which have log Koc value ranging from 1.5 to 5.0. The log Koc was estimated to be 1.59 and the Koc 39.
Information on Registered Substances comes from registration dossiers which have been assigned a registration number. The assignment of a registration number does however not guarantee that the information in the dossier is correct or that the dossier is compliant with Regulation (EC) No 1907/2006 (the REACH Regulation). This information has not been reviewed or verified by the Agency or any other authority. The content is subject to change without prior notice.