Registration Dossier

Diss Factsheets

Administrative data

Endpoint:
auto-flammability
Type of information:
experimental study
Adequacy of study:
key study
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
other: Meets the criteria for classification as Reliable without restriction according to Klimisch et al (1997)

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
1997

Materials and methods

Test guideline
Qualifier:
according to guideline
Guideline:
other: 92/69/EEC, A16
GLP compliance:
yes

Test material

Reference
Name:
Unnamed
Type:
Constituent

Results and discussion

Auto-ignition temperature (liquids / gases)
Auto-ignition temperature:
> 450 °C
Atm. press.:
101.3 kPa
Remarks on result:
other:
Relative self-ignition temperature (solids)
Relative self-ignition temperature:
> 450 °C
Remarks on result:
other:
Remarks:
at atm. press. of 101.3 kPa

Any other information on results incl. tables

The relative self-ignition of solids (A16) was peformed because auto-ignition temperature (A15) could not be done due to the viscous nature of the test substance.
Under the conditions of the test, the substance did not self-ignite.

Applicant's summary and conclusion