Determination of the vapor pressure of TK 13332.

Key value for chemical safety assessment

Vapour pressure:
0 Pa
at the temperature of:
25 °C

Additional information

The vapor pressure of the test item has been determined to be less than 1.3E-04 Pa at 25 °C, using the vapour pressure balance method, designed to be compatible with Method 104 of the OECD Guidelines for Testing of Chemicals, 23 March 2006.