Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Administrative data

Endpoint:
auto-flammability
Type of information:
experimental study
Adequacy of study:
key study
Study period:
27 January 2015 - 23 April 2015
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
other: GLP-compliant study in accordance with EC A.15.

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
2015
Report date:
2015

Materials and methods

Test guidelineopen allclose all
Qualifier:
according to guideline
Guideline:
EU Method A.15 (Auto-Ignition Temperature (Liquids and Gases))
Version / remarks:
(2008)
Deviations:
no
Qualifier:
according to guideline
Guideline:
other: DIN 51794: "Determining the Ignition Temperature of Petroleum Products" (2003)
Deviations:
no
Qualifier:
according to guideline
Guideline:
other: IEC 79-4: "Electrical Apparatus for Explosive Gas Atmospheres, Part 4, Method of Test for Ignition Temperature" (1975)
Deviations:
no
GLP compliance:
yes

Test material

Constituent 1
Chemical structure
Reference substance name:
3,3,4,4,5,5,6,6,7,7,8,8,8-tridecafluorooctane-1-thiol
EC Number:
628-448-8
Cas Number:
34451-26-8
Molecular formula:
C8H5F13S
IUPAC Name:
3,3,4,4,5,5,6,6,7,7,8,8,8-tridecafluorooctane-1-thiol
Details on test material:
- Name (as cited in study report): NS-1000
- Appearance: Clear colourless liquid

Results and discussion

Auto-ignition temperature (liquids / gases)
Auto-ignition temperature:
315 °C
Atm. press.:
1 029.4 - 1 040.8 hPa
Remarks on result:
other: The reported auto-ignition temperature is the lowest auto-ignition temperature measured for the substance (see table below).

Any other information on results incl. tables

Table: Results of the auto-ignition temperature measurements:

Test

Volume

[μL]

Start temperature

[°C]

End temperature

[°C]

Auto-ignition temperature

[°C]

Ignition delay

[s]

Colour of the flame

Minimum auto-ignition temperature[°C]

1

70

333

323

325

69

Blue

316

150

324

314

316

154

Blue

300

365

359

361

35

Orange

2

60

334

322

324

56

Orange

315

140

349

313

315

143

Orange

200

360

346

348

56

Orange

3

50

332

326

328

47

Orange

317

130

325

315

317

126

Blue

180

354

334

336

61

Orange/Blue

Applicant's summary and conclusion

Conclusions:
In a GLP-compliant study in accordance with EC A.15, DIN 51794 and IEC 79-4, the auto-ignition temperature of the substance at 1029.4 – 1040.8 hPa has been determined as 315°C.