Registration Dossier

Diss Factsheets

Physical & Chemical properties

Vapour pressure

Currently viewing:

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
vapour pressure
Data waiving:
study scientifically not necessary / other information available
Justification for data waiving:
the study does not need to be conducted because the melting point is above 300°C

Description of key information

In accordance with Column 2 of REACH Annex VII, the vapour pressure study does not need to be conducted if the melting point is above 300 °C. No melting point could be detected until 300°C for FAT 21036/G, the study is waived off.

However, the vapour pressure is considered negligible (0.000001 Pa assumed for risk assessment tool) and its numerical determination is not considered scientifically justified.

Key value for chemical safety assessment

Vapour pressure:
0 Pa
at the temperature of:
20 °C

Additional information