Registration Dossier

Diss Factsheets

Administrative data

Endpoint:
relative density
Type of information:
experimental study
Adequacy of study:
key study
Study period:
2013
Reliability:
2 (reliable with restrictions)
Rationale for reliability incl. deficiencies:
other: Guideline study (ISO 1183); basic data given.

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
2013
Report date:
2013

Materials and methods

Test guideline
Qualifier:
according to guideline
Guideline:
other: ISO 1183
Deviations:
no
GLP compliance:
no
Type of method:
pycnometer method

Test material

Constituent 1
Reference substance name:
Montan waxes, type CaV 102
IUPAC Name:
Montan waxes, type CaV 102
Details on test material:
Product Name: Licomont CAV 102 FG
Purity: 100%

Results and discussion

Density
Key result
Type:
relative density
Density:
1.036
Temp.:
23 °C

Any other information on results incl. tables

Mean of 3 measurements (1.035/1.035/1.037).

Standard dev.: 0.00115

Applicant's summary and conclusion

Conclusions:
The test substance has a relative density of 1.036.
Executive summary:

The relative density of the test substance was determined by the Helium-pycnometer method according to ISO 1183. The test substance has a relative density of 1.036 at 23°C.