Registration Dossier

Diss Factsheets

Physical & Chemical properties

Particle size distribution (Granulometry)

Currently viewing:

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
particle size distribution (granulometry)
Type of information:
experimental study
Adequacy of study:
key study
Study period:
2017
Reliability:
2 (reliable with restrictions)
Rationale for reliability incl. deficiencies:
other: well performed study according to acknowledged standard
Qualifier:
according to guideline
Guideline:
other: ISO 13320 -1
GLP compliance:
no
Type of method:
Laser scattering/diffraction
Type of distribution:
volumetric distribution
Percentile:
D10
Mean:
2.9 µm
St. dev.:
0.1
Percentile:
D50
Mean:
13.7 µm
St. dev.:
1.8
Percentile:
D90
Mean:
214 µm
St. dev.:
58
Conclusions:
The mass median diameter is 13.7 µm.
Executive summary:

The volumetric particle size distribution of the substance was determined with the following equipment: Malvern Mastersizer 2000, unit: Scirocco 2000.

The mass median diameter D50 could be determined as 13.7 µm.

Description of key information

ISO 13320-1, laser scattering diffraction


D10=2.9 µm


D50=13.7 µm


D90=214 µm

Additional information

volumetric distribution