Registration Dossier

Diss Factsheets

Physical & Chemical properties

Viscosity

Currently viewing:

Administrative data

Link to relevant study record(s)

Referenceopen allclose all

Endpoint:
viscosity
Type of information:
experimental study
Adequacy of study:
supporting study
Reliability:
2 (reliable with restrictions)
Rationale for reliability incl. deficiencies:
other: Basic data given. Certificate of Analysis.
Qualifier:
according to guideline
Guideline:
other: DIN 51562 T1
Principles of method if other than guideline:
Test was done according to the method DIN 51562 T1, 83 MOD ( acc. to EN 10204).
GLP compliance:
not specified
Remarks:
No more details available, data from CoA.
Type of method:
capillary viscometer (static)
Temp.:
40°C
Parameter:
kinematic viscosity (in mm²/s)
Value:
82.9
Endpoint:
viscosity
Type of information:
experimental study
Adequacy of study:
supporting study
Reliability:
2 (reliable with restrictions)
Rationale for reliability incl. deficiencies:
other: Basic data given. Certificate of Analysis.
Principles of method if other than guideline:
No more details about method available.
GLP compliance:
no
Type of method:
other: measured
Temp.:
40°C
Parameter:
kinematic viscosity (in mm²/s)
Value:
83
Remarks on result:
other: kinematic viscosity
Endpoint:
viscosity
Type of information:
experimental study
Adequacy of study:
supporting study
Reliability:
2 (reliable with restrictions)
Rationale for reliability incl. deficiencies:
other: Basic data given. Certificate of Analysis.
Principles of method if other than guideline:
No more details available about method.
GLP compliance:
no
Type of method:
other: measured
Temp.:
other: 100.0°C
Parameter:
kinematic viscosity (in mm²/s)
Value:
13.8
Endpoint:
viscosity
Type of information:
experimental study
Adequacy of study:
key study
Reliability:
2 (reliable with restrictions)
Rationale for reliability incl. deficiencies:
other: Basic data given. Certificate of Analysis.
Qualifier:
according to guideline
Guideline:
other: ASTM D 445
Principles of method if other than guideline:
Test was done according to the method ASTM D445.
GLP compliance:
no
Type of method:
capillary viscometer (static)
Temp.:
40°C
Parameter:
other: cSt
Value:
100

Description of key information

100 cSt at 40 °C

Key value for chemical safety assessment

Additional information

The viscosity of the substance fatty acids, C16 -18 (even numbered) and C18-unsatd., branched and linear, di- and triesters with trimethylolpropane (former CAS 85005 -23 -8) was determined according to ASTM D 445 using the capillary method.

Further determination according to DIN 51562 T1 (capillary method; 82.9 mm²/s at 40 °C) and with no further specification of method (83 mm²/s at 40 °C) are supporting.

Another determination of viscosity at 100 °C was done: 13.8 mm²/s.