Registration Dossier

Diss Factsheets

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
flammable solids
Type of information:
experimental study
Adequacy of study:
key study
Study period:
The study was conducted between 23 September 2015 and 02 December 2015
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
other: GLP guideline study
Qualifier:
according to guideline
Guideline:
EU Method A.10 (Flammability (Solids))
Deviations:
no
GLP compliance:
yes (incl. QA statement)
Parameter:
lower explosion limit
Remarks on result:
other: Not assessed
Parameter:
upper explosion limit
Remarks on result:
other: Not assessed
Type of aerosol tested:
aerosol dispenser: not specified
Remarks:
or specified in description of method (migrated information)
Test parameter:
ignition distance (cm)
Remarks:
original parameter: flame extension (cm) (migrated information)
Remarks on result:
other: Not assessed
Type of aerosol tested:
aerosol dispenser: not specified
Remarks:
or specified in description of method (migrated information)
Test parameter:
maximum flame height (cm)
Remarks:
original parameter: flame projection (cm) (migrated information)
Remarks on result:
other: Not assessed
Test procedure:
burning time (test type not further specified)
Remarks:
or specified in description of method (migrated information)
Remarks on result:
other: Not assessed
Test procedure:
ignition time on contact with air
Remarks:
Ignition on contact with air refers to either Pyrophoric solids or Pyrophoric liquids depending on physical state (migrated information).
Remarks on result:
no ignition on contact with air (not further specified)
Remarks:
corresponding to 'no' in migrated source record. | Remarks: | Additional remarks: The pile failed to ignite during the 2 minutes that the Bunsen flame was applied.
Test procedure:
ignition time on contact with air
Remarks:
Ignition on contact with air refers to either Pyrophoric solids or Pyrophoric liquids depending on physical state (migrated information).
Remarks on result:
no ignition on contact with air (not further specified)
Remarks:
corresponding to 'no' in migrated source record. | Remarks: | Additional remarks: The pile failed to ignite during the 2 minutes that the Bunsen flame was applied.
Remarks on result:
other: Not assessed

Preliminary screening test

The pile failed to ignite during the 2 minutes that the Bunsen flame was applied.

The result of the preliminary screening test obviated the need to perform the main test.

Interpretation of results:
non flammable
Remarks:
Migrated information
Conclusions:
The test item has been determined to be not highly flammable as it failed to ignite in the preliminary screening test.
Executive summary:

Flammability (Solids). Not highly flammable, using a procedure designed to be compatible with Method A10 Flammability (Solids) of Commission Regulation (EC) No 440/2008 of 30 May 2008.

Description of key information

The test item is not highly flammable, using a procedure designed to be compatible with Method A10 Flammability (Solids) of Commission Regulation (EC) No 440/2008 of 30 May 2008.

Key value for chemical safety assessment

Flammability:
not classified

Additional information

The test item is not highly flammable.

Justification for classification or non-classification