Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Administrative data

Endpoint:
dissociation constant
Type of information:
experimental study
Adequacy of study:
supporting study
Reliability:
1 (reliable without restriction)

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
2012
Report date:
2012

Materials and methods

Test guidelineopen allclose all
Qualifier:
according to guideline
Guideline:
OECD Guideline 112 (Dissociation Constants in Water)
Deviations:
no
Remarks:
Study conducted according to guideline in effect at time of study conduct
Qualifier:
according to guideline
Guideline:
EPA OPPTS 830.7370 (Dissociation constants in water)
Deviations:
no
Remarks:
Study conducted according to guideline in effect at time of study conduct
GLP compliance:
yes

Test material

Constituent 1
Details on test material:
- Purity: 93%

Results and discussion

Dissociating properties:
no
Dissociation constant
Remarks on result:
other: dissociation constant was not obtained from the titration curves

Any other information on results incl. tables

Both titration curves (with NaOH and with HCl) showed no equivalent point and they are nearly identical to water.

Applicant's summary and conclusion

Conclusions:
A dissociation constant was not obtained. Both titration curves (with NaOH and with HCl) showed no equivalent point and they are nearly identical to water.
Executive summary:

A dissociation constant was not obtained from the titration curves according to OECD Guideline 112. Both titration curves (with NaOH and with HCl) showed no equivalent point and they are nearly identical to water.