Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Physical & Chemical properties

Flash point

Currently viewing:

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
flash point of flammable liquids
Type of information:
experimental study
Adequacy of study:
key study
Reliability:
2 (reliable with restrictions)
Rationale for reliability incl. deficiencies:
guideline study with acceptable restrictions
Justification for type of information:
Guideline method conducted in a reliable industry laboratory, but without CLP certification.
Qualifier:
according to guideline
Guideline:
ISO 2719 (Determination of flash point - Pensky-Martens closed cup method)
GLP compliance:
no
Type of method:
closed cup
Flash point apparatus:
Pensky-Martens apparatus
Key result
Flash point:
187 °C
Atm. press.:
101.3 kPa
Remarks on result:
other: assume standard atmospheric pressure
Interpretation of results:
GHS criteria not met
Conclusions:
The test substance demonstrated a flash point of 187˚C.

Description of key information

187˚C

Key value for chemical safety assessment

Flash point at 101 325 Pa:
187 °C

Additional information

The test substance demonstrated a flash point of 187˚C.