Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Physical & Chemical properties

Flash point

Currently viewing:

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
flash point of flammable liquids
Type of information:
experimental study
Adequacy of study:
key study
Study period:
December 2016
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study
Qualifier:
according to guideline
Guideline:
ASTM D93 (Standard test methods for flash point by pensky-martens closed cup tester)
Deviations:
no
GLP compliance:
no
Type of method:
closed cup
Flash point apparatus:
Pensky-Martens apparatus
Key result
Flash point:
> 220 °C
Atm. press.:
101.325 kPa
Remarks on result:
no flash point according to standard method

No flash point was observed with the test material over the temperature range 10°C to 220°C.

Interpretation of results:
GHS criteria not met
Conclusions:
No flash point was observed with the test material over the temperature range 10°C to 220°C. The test item did not meet the criteria for classification according to Regulation (EC) No.1272/2008 on the Classification, Labelling and Packaging of Substances and Mixtures.
Executive summary:

The flash point of the substance was evaluated according to the method ASTM D93 using a Pensky-Martens Closed Cup. No flash point was observed with the test material over the temperature range 10°C to 220°C. The test item did not meet the criteria for classification according to Regulation (EC) No.1272/2008 on the Classification, Labelling and Packaging of Substances and Mixtures.

Description of key information

The flash point of the substance was evaluated according to method ASTM D93 using a Pensky-Martens Closed Cup. No flash point was observed with the test material over the temperature range 10°C to 220°C. The test item did not meet the criteria for classification as a flammable liquid according to Regulation (EC) N° 1272/2008.

Key value for chemical safety assessment

Additional information