Registration Dossier

Diss Factsheets

Physical & Chemical properties

Flash point

Currently viewing:

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
flash point of flammable liquids
Type of information:
experimental study
Adequacy of study:
key study
Study period:
18-Nov-2014
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study
Reason / purpose for cross-reference:
reference to same study
Qualifier:
according to guideline
Guideline:
EU Method A.9 (Flash-Point)
Qualifier:
according to guideline
Guideline:
ISO 2719 (Determination of flash point - Pensky-Martens closed cup method)
Version / remarks:
2003
Qualifier:
according to guideline
Guideline:
EPA OPPTS 830.6315 (Flammability)
Qualifier:
according to guideline
Guideline:
ISO No., other: CIPAC MT 12 (2009)
GLP compliance:
no
Type of method:
non-equilibrium method closed cup
Remarks:
Pensky-Martens
Key result
Flash point:
84.5 °C
Atm. press.:
1 000 hPa

Results

Preliminary test

The results of the pre-test with the search program are summarised in the following table. The result “ignition” is indicated by + and “no ignition” by -.

 

Preliminary test

Amount of test item / g

Temperature / °C

Ignition (+/-)

Air pressure / hPa

Flash point (corr.) / °C

65.13

86.0

+

1000.0

86.325

 

In the preliminary test the lowest temperature where an ignition was observed was 86.0 °C.

The result of the main test is summarised in the following table. The result “ignition” is indicated by + and “no ignition” by -.

 

Main test

Amount of test item / g

Temperature / °C

Ignition (+/-)

Air pressure / hPa

Flash point (corr.) / °C

65.07

84.0

+

1000.0

84.325

64.80

85.0

+

1000.0

85.325

 

In the main test the lowest temperature where an ignition was observed was 84.0 °C.

The average measured flash point is corrected to the ambient pressure to be 84.825 °C

The resulting average corrected flash point rounded down to the nearest multiple of 0.5 °C is 84.5 °C.

 

Final results

The test item has a flash point of 84.5 °C (average corrected and rounded down to the nearest multiple of 0.5 °C according to Regulation EC No. 440/2008 Method A.9 Flash Point, CIPAC MT 12 (2009) and Guideline OCSPP 830.6315 (1996).  

Conclusions:
A flash point value of 84.5 °C (at 1000 hPa) was determined for the test substance according to E.U. Method A.9.

Description of key information

Flash point: 84.5 °C at 1000 hPa (EU Method A.9, Pensky-Martens, non-equilibrium, closed cup method)

Key value for chemical safety assessment

Flash point at 101 325 Pa:
84.5 °C

Additional information